Characteristics of Heat Resistant Aluminum Alloy Composite Core Conductor Used in overhead Power Transmission Lines
View through CrossRef
The heat resistant aluminum alloy wire composite material core conductor (ACCC/HW) which was used in overhead transmission lines is developed and studied in this work. The composite material core is carbon fiber/glass cloth reinforced modified epoxy resin composite. Tensile stress tests and stress-strain tests of both composite core and conductor are taken at 25 °C and 160 °C. Sag test, creep test and current carrying capacity test of composite conductor are taken. The stress of composite conductor are 425.2 MPa and 366.9 MPa at 25 °C and 160 °C, respectively. The sag of conductor of 50 m length are 95 mm, 367 mm, and 371 mm at 25 °C, 110 °C, and 160 °C, respectively. The creep strain are 271 mm/km, 522 mm/km, and 867 mm/km after 10 years under the tension of 15% RTS (Rated Tensile Strength), 25% RTS and 35% RTS at 25 °C, and 628 mm/km under 25% RTS at 160 °C, according to the test result and calculation. The carrying capacity of composite conductor is basically equivalent to ACSR (Aluminum Conductor Steel Reinforced). ACCC/HW is suitable in overhead transmission lines, and it has been used in 50 kV power grid, according to the results.
Title: Characteristics of Heat Resistant Aluminum Alloy Composite Core Conductor Used in overhead Power Transmission Lines
Description:
The heat resistant aluminum alloy wire composite material core conductor (ACCC/HW) which was used in overhead transmission lines is developed and studied in this work.
The composite material core is carbon fiber/glass cloth reinforced modified epoxy resin composite.
Tensile stress tests and stress-strain tests of both composite core and conductor are taken at 25 °C and 160 °C.
Sag test, creep test and current carrying capacity test of composite conductor are taken.
The stress of composite conductor are 425.
2 MPa and 366.
9 MPa at 25 °C and 160 °C, respectively.
The sag of conductor of 50 m length are 95 mm, 367 mm, and 371 mm at 25 °C, 110 °C, and 160 °C, respectively.
The creep strain are 271 mm/km, 522 mm/km, and 867 mm/km after 10 years under the tension of 15% RTS (Rated Tensile Strength), 25% RTS and 35% RTS at 25 °C, and 628 mm/km under 25% RTS at 160 °C, according to the test result and calculation.
The carrying capacity of composite conductor is basically equivalent to ACSR (Aluminum Conductor Steel Reinforced).
ACCC/HW is suitable in overhead transmission lines, and it has been used in 50 kV power grid, according to the results.
Related Results
Magnesium Heat Sink Evaluations
Magnesium Heat Sink Evaluations
<div class="htmlview paragraph">A system has been constructed to estimate heat dissipated from geometrically identical heat sinks and pinfins extruded from magnesium (M1A) an...
Effect of Al-Ti-C-La Composite Alloy on Microstructure and Mechanical Properties of 6063 Aluminum Alloy
Effect of Al-Ti-C-La Composite Alloy on Microstructure and Mechanical Properties of 6063 Aluminum Alloy
In this paper, 6063 aluminum alloy for common building profiles is used as the research object. By adding a new Al-Ti-C-La composite alloy, the effect of 6063 aluminum alloy on the...
Bearing Characteristics of Composite Conductor Structure: Deepwater Conductor Pipe with Suction Bucket Foundation
Bearing Characteristics of Composite Conductor Structure: Deepwater Conductor Pipe with Suction Bucket Foundation
Abstract
In order to improve the vertical and lateral load bearing capacity of the drilling conductor, composite design of bucket foundation and drilling conductor w...
Probabilistic Fatigue Fragility Curves for Overhead Transmission Line Conductor-Clamp Assemblies
Probabilistic Fatigue Fragility Curves for Overhead Transmission Line Conductor-Clamp Assemblies
The residual life of transmission line overhead conductors under conditions of fretting fatigue is an important asset management issue for electric network operators. The current i...
Analyses and Measurements of Conductor Response for Jack-up Drilled Wells in 110 m Water Depth in Harsh Environments.
Analyses and Measurements of Conductor Response for Jack-up Drilled Wells in 110 m Water Depth in Harsh Environments.
Abstract
The analysis of conductor systems for wells drilled by jack-ups is often limited to analysis of the conductor alone as a free standing unit. This paper d...
Improvement of Conductor Driving Operation for Deeper Penetration to Prevent Drive-Drill Operation: Cost-Effective and Efficient Conductor Installation in Offshore East Java, Indonesia
Improvement of Conductor Driving Operation for Deeper Penetration to Prevent Drive-Drill Operation: Cost-Effective and Efficient Conductor Installation in Offshore East Java, Indonesia
Abstract
In December 2021, Husky-CNOOC Madura Limited (HCML) commenced the ten (10) wells development drilling campaign of three (3) fields (Field M1, Field M2, and ...
Ceramic Coatings for Aluminum Engine Blocks
Ceramic Coatings for Aluminum Engine Blocks
<div class="htmlview paragraph">The trend toward lighter vehicles for improved performance has recently introduced the use of aluminum and plastic materials for vehicle bodie...
Effect of ocean heat flux on Titan's topography and tectonic stresses
Effect of ocean heat flux on Titan's topography and tectonic stresses
INTRODUCTIONThe thermo-mechanical evolution of Titan's ice shell is primarily controlled by the mode of the heat transfer in the ice shell and the amount of heat coming from the oc...