Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Implant failure following pedicle based dynamic stabilization of the lumbar spine

View through CrossRef
Pedicle-based dynamic stabilization (PBDS) devices such as Dynesys are promoted as an alternative and less invasive option for rigid stabilization of one and even more levels of the lumbar spine. Promising features of the Dynesys system, as well as shortcomings, became obvious in several clinical studies. Since 2012, we started using a new PBDS device as an alternative for the Dynesys, to avoid the screw loosening and the kyphosing effect. The objective is to compare failure rates between the Dynesys and Balan-C type PBDS implant and factors affecting outcome. In a retrospective study we investigated a total of 90 patients with lumbar pedicle screw dynamic stabilization (a group of 64 patiënts with Dynesys stabilization is compared to a group of 26 patients with Balan-C stabilization). Mean follow-up was 48 and 38 months, respectively. Using logistic regression analysis the impact of baseline characteristics such as gender, age, body mass index (BMI), indication for surgery, primary or revision surgery, single versus more level surgery, surgeon’s experience and type of the implant on implant failure was analyzed. We found a statistically significant difference in failure rates between the two systems (13% in the Dynesys group versus 62% in the Balan-C group). In multivariate analysis, type of implant was associated with implant failure (odds ratio : 13). Our current results call for an optimization of the pre-and post-marketing surveillance of pedicle-based dynamic stabilization.
Title: Implant failure following pedicle based dynamic stabilization of the lumbar spine
Description:
Pedicle-based dynamic stabilization (PBDS) devices such as Dynesys are promoted as an alternative and less invasive option for rigid stabilization of one and even more levels of the lumbar spine.
Promising features of the Dynesys system, as well as shortcomings, became obvious in several clinical studies.
Since 2012, we started using a new PBDS device as an alternative for the Dynesys, to avoid the screw loosening and the kyphosing effect.
The objective is to compare failure rates between the Dynesys and Balan-C type PBDS implant and factors affecting outcome.
In a retrospective study we investigated a total of 90 patients with lumbar pedicle screw dynamic stabilization (a group of 64 patiënts with Dynesys stabilization is compared to a group of 26 patients with Balan-C stabilization).
Mean follow-up was 48 and 38 months, respectively.
Using logistic regression analysis the impact of baseline characteristics such as gender, age, body mass index (BMI), indication for surgery, primary or revision surgery, single versus more level surgery, surgeon’s experience and type of the implant on implant failure was analyzed.
We found a statistically significant difference in failure rates between the two systems (13% in the Dynesys group versus 62% in the Balan-C group).
In multivariate analysis, type of implant was associated with implant failure (odds ratio : 13).
Our current results call for an optimization of the pre-and post-marketing surveillance of pedicle-based dynamic stabilization.

Related Results

Effect Comparison Of MIS-TLIF Under MED and Quadrant Modes in The Treatment of Lu mbar Spinal Stenosis
Effect Comparison Of MIS-TLIF Under MED and Quadrant Modes in The Treatment of Lu mbar Spinal Stenosis
Background Lumbar spinal stenosis is one of the common causes of low back and leg pain. Lumbar intervertebral disc degeneration leads to the decrease of intervertebral height, the ...
Stiffness Comparisons of SOP Interlocking Plate Configurations in 3D Printed Canine Lumbosacral Vertebrae
Stiffness Comparisons of SOP Interlocking Plate Configurations in 3D Printed Canine Lumbosacral Vertebrae
There are no published biomechanical studies evaluating the effect of stabilization techniques on the stability of the 3D printed models of the canine lumbosacral junction. The p...
The Evaluation of a Novel Three-Dimensional Printed Expandable Pedicle Screw Sleeve Insert
The Evaluation of a Novel Three-Dimensional Printed Expandable Pedicle Screw Sleeve Insert
When used in combination with decompression, spinal fusion is a successful procedure for treating patients with spinal stenosis and degenerative spondylolisthesis. While a number o...
Radiological Analysis of Sagittal and Cross-sectional Morphology of Congenital Lumbar Spinal Stenosis
Radiological Analysis of Sagittal and Cross-sectional Morphology of Congenital Lumbar Spinal Stenosis
Abstract Background Purpose This retrospective study was applied to investigate the morphology characteristics of the spine and pelvis in patients with congenital spinal s...
Biomechanical characterization of bilateral pedicle screw internal fixation combinations on lumbar vertebrae
Biomechanical characterization of bilateral pedicle screw internal fixation combinations on lumbar vertebrae
Purpose Pedicle screw fixation has been considered a suitable surgical intervention for addressing a diverse range of indications involving the lumbar spinal segments, but the...
Spinal cord injury as a component of polytrauma in road accident victims
Spinal cord injury as a component of polytrauma in road accident victims
Background. Road traffic injury remains one of the most serious and complex types of human injury both in Ukraine and around the world. The purpose of the research: to determine th...
Minimally invasive transabdominal preperitoneal repair of incisional lumbar hernia
Minimally invasive transabdominal preperitoneal repair of incisional lumbar hernia
Introduction: A lumbar hernia is a rare type of abdominal wall defect by anatomic location. It can be primary in origin over the lumbar triangles that can be categorized into super...

Back to Top