Javascript must be enabled to continue!
Comparison of Colorado Needle Electrocautery and Traditional Scalpel for Upper Eyelid Blepharoplasty Incision: A Randomized Controlled Trial and Systematic Review
View through CrossRef
Background:
Upper eyelid blepharoplasty is a popular aesthetic surgery. Electrocautery provides a hemostatic benefit for skin incision; however, its effect on scar cosmesis remains unclear, especially in Asian skin types. We aimed to compare the Colorado needle electrocautery pure cutting mode and the traditional scalpel to determine their efficacy, complications, and cosmetic outcomes.
Methods:
A systematic review was performed to review the outcome with the conventional method (scalpel) and other methods in upper blepharoplasty procedures. Further, a prospective intraindividual randomized controlled trial was conducted to compare the efficacy of Colorado needle electrocautery and the scalpel in upper blepharoplasty. Study outcomes included scar quality at different times until 1-year postoperation, bleeding during incision, and postoperative ecchymosis.
Results:
Five articles met the inclusion criteria for this systematic review. The prospective randomized controlled trial study included 30 patients; the average incisional time on the electrocautery side was significantly longer than that on the scalpel side, and the electrocautery side had less blood loss during incision than the scalpel side (2.4 versus 3.27 using average cotton bud sticks, respectively) (P < 0.001). Hypopigmented scarring occurred more frequently on the scalpel side; however, the difference was not statistically significant.
Conclusions:
Colorado needle electrocautery pure cutting mode can be an alternative to traditional scalpel for upper eyelid blepharoplasty skin incision because of long-term scar quality. Electrocautery use has hemostatic benefits, leading to a decrease in bleeding that can obscure the incision site. However, the incision time on the electrocautery side was significantly longer than the scalpel side, which may be owing to an adaptation of surgical technique.
Ovid Technologies (Wolters Kluwer Health)
Title: Comparison of Colorado Needle Electrocautery and Traditional Scalpel for Upper Eyelid Blepharoplasty Incision: A Randomized Controlled Trial and Systematic Review
Description:
Background:
Upper eyelid blepharoplasty is a popular aesthetic surgery.
Electrocautery provides a hemostatic benefit for skin incision; however, its effect on scar cosmesis remains unclear, especially in Asian skin types.
We aimed to compare the Colorado needle electrocautery pure cutting mode and the traditional scalpel to determine their efficacy, complications, and cosmetic outcomes.
Methods:
A systematic review was performed to review the outcome with the conventional method (scalpel) and other methods in upper blepharoplasty procedures.
Further, a prospective intraindividual randomized controlled trial was conducted to compare the efficacy of Colorado needle electrocautery and the scalpel in upper blepharoplasty.
Study outcomes included scar quality at different times until 1-year postoperation, bleeding during incision, and postoperative ecchymosis.
Results:
Five articles met the inclusion criteria for this systematic review.
The prospective randomized controlled trial study included 30 patients; the average incisional time on the electrocautery side was significantly longer than that on the scalpel side, and the electrocautery side had less blood loss during incision than the scalpel side (2.
4 versus 3.
27 using average cotton bud sticks, respectively) (P < 0.
001).
Hypopigmented scarring occurred more frequently on the scalpel side; however, the difference was not statistically significant.
Conclusions:
Colorado needle electrocautery pure cutting mode can be an alternative to traditional scalpel for upper eyelid blepharoplasty skin incision because of long-term scar quality.
Electrocautery use has hemostatic benefits, leading to a decrease in bleeding that can obscure the incision site.
However, the incision time on the electrocautery side was significantly longer than the scalpel side, which may be owing to an adaptation of surgical technique.
Related Results
Functional and aesthetic comparison of lower lip split incisions and modification of McGregor incision. (Preprint)
Functional and aesthetic comparison of lower lip split incisions and modification of McGregor incision. (Preprint)
BACKGROUND
The open mouth provided the basis for various surgical approaches to tumours of the oral cavity(1). If this access is inadequate it is generally ...
Comparison of Colorado Needle Electrocautery and Traditional Scalpel for Lower Eyelid Blepharoplasty Incision: A Randomized Controlled Trial
Comparison of Colorado Needle Electrocautery and Traditional Scalpel for Lower Eyelid Blepharoplasty Incision: A Randomized Controlled Trial
Background:
Lower eyelid blepharoplasty is one of the most popular aesthetic procedures. Electrocautery provides a hemostatic benefit for skin incision; however, its ef...
Comparison of Electrocautery and Scalpel Incision in Midline Abdominal Surgery
Comparison of Electrocautery and Scalpel Incision in Midline Abdominal Surgery
Background: With the advancement of surgical techniques, the comparison of electrocautery and scalpel incisions in midline abdominal surgeries has become an essential area of study...
A Study to Compare the Safety and Efficacy of Cutting Electrocautery Versus Scalpel Skin Incisions in Elective Abdominal Surgeries
A Study to Compare the Safety and Efficacy of Cutting Electrocautery Versus Scalpel Skin Incisions in Elective Abdominal Surgeries
Background: Skin incision is an important initial step in elective abdominal surgery and may influence operative blood loss, incision time, postoperative pain, and wound outcomes. ...
Comparison Of Midline Abdominal Surgery Using Scalpel Versus Electrocautery Incision in Rural Indian Population
Comparison Of Midline Abdominal Surgery Using Scalpel Versus Electrocautery Incision in Rural Indian Population
The scalpel was considered a gold standard for making skin incisions until the inception of diathermy. Nowadays, electrodes used in making diathermy incisions generate a pure sinus...
Bikini Incision Modification of the Direct Anterior Approach
Bikini Incision Modification of the Direct Anterior Approach
Background:
Although the direct anterior approach (DAA) represents an intermuscular and internervous approach to total hip arthroplasty (THA), it did not reach global a...
Abdominal Wound Problem after Hysterectomy using Scalpel Versus Electrocautery for Skin and Subcutaneous Dissection
Abdominal Wound Problem after Hysterectomy using Scalpel Versus Electrocautery for Skin and Subcutaneous Dissection
Objective: To evaluate the postoperative abdominal wound problem after hysterectomy with scalpel versus electrocautery for skin and subcutaneous dissection. Material and Methods: A...
Safety and Efficacy of Atezolizumab in Ovarian Cancer
Safety and Efficacy of Atezolizumab in Ovarian Cancer
Abstract
Introduction
Although the efficacy of PD-L1 blockade has been evaluated in analyses that combine pharmacologically distinct antibodies, the specific efficacy and safety of...

