Abstract
Streak Tube Imaging Lidar (STIL), with advantages of non-scanning working mode, small distortion, high image framing rate, high resolution in low contrast environment, compact structure, easy miniaturization and high reliability, has a wide range of applications in military, aerospace, space confrontation, attack and defense, and marine law enforcement. This article introduces the principle of single-slit and multi-slit streak tube imaging lidar. It also introduces a single-slit general streak camera that can be used for imaging lidar. In addition, a multi-slit miniaturized streak tube with a single-lens focusing system with a total length of about 200 mm has been designed. The results of the 3D electromagnetic simulation show that the effective photocathode area of this streak tube reaches 36 mm × 36 mm, the temporal resolution is better than 50 ps, the dynamic spatial resolution can reach 12 lp/mm, and the whole photocathode can accommodate at least 19 slits in the effective detection range. The streak tube has a meshless structure, which is highly reliable. The streak tube can be used to increase the field of view of the imaging lidar system, improve the reliability, and achieve system miniaturization.
Walter de Gruyter GmbH
Title: 3-D Imaging Lidar Based on Miniaturized Streak Tube
Description:
Abstract
Streak Tube Imaging Lidar (STIL), with advantages of non-scanning working mode, small distortion, high image framing rate, high resolution in low contrast environment, compact structure, easy miniaturization and high reliability, has a wide range of applications in military, aerospace, space confrontation, attack and defense, and marine law enforcement.
This article introduces the principle of single-slit and multi-slit streak tube imaging lidar.
It also introduces a single-slit general streak camera that can be used for imaging lidar.
In addition, a multi-slit miniaturized streak tube with a single-lens focusing system with a total length of about 200 mm has been designed.
The results of the 3D electromagnetic simulation show that the effective photocathode area of this streak tube reaches 36 mm × 36 mm, the temporal resolution is better than 50 ps, the dynamic spatial resolution can reach 12 lp/mm, and the whole photocathode can accommodate at least 19 slits in the effective detection range.
The streak tube has a meshless structure, which is highly reliable.
The streak tube can be used to increase the field of view of the imaging lidar system, improve the reliability, and achieve system miniaturization.
Related Results
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Development of a multimodal imaging system based on LIDAR
Development of a multimodal imaging system based on LIDAR
(English) Perception of the environment is an essential requirement for the fields of autonomous vehicles and robotics, that claim for high amounts of data to make reliable decisio...
A compact large-format streak tube for imaging lidar
A compact large-format streak tube for imaging lidar
The streak tubes with a large effective photocathode area, large effective phosphor screen area, and high photocathode radiant sensitivity are essential for improving the field of ...
Airborne LiDAR for DEM generation: some critical issues
Airborne LiDAR for DEM generation: some critical issues
Airborne LiDAR is one of the most effective and reliable means of terrain data collection. Using LiDAR data for digital elevation model (DEM) generation is becoming a standard prac...
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
Improving the ranging performance of chaos LiDAR
Improving the ranging performance of chaos LiDAR
Chaos lidar has gained significant attention due to its high spatial resolution, natural anti-interference capability, and confidentiality. However, constrained by the power of the...
Streak Tube-Based LiDAR for 3D Imaging
Streak Tube-Based LiDAR for 3D Imaging
Streak cameras, essential for ultrahigh temporal resolution diagnostics in laser-driven inertial confinement fusion, underpin the streak tube imaging LiDAR (STIL) system—a flash Li...