An Experimental Study of the Effects of Crack and Detachment on Insulation Properties of Intumescent Coating
View through CrossRef
AbstractThis paper presents the results of an experimental study to investigate the failure modes of intumescent coatings and their effects on temperatures attained in steel sections and load carrying capacities of steel columns. Primer and intumescent coatings were applied to unloaded steel plates, unloaded I‐shaped short sections and axially loaded I‐shaped long columns. For the axially loaded columns, three different surface treatments were considered. The failure modes of intumescent coatings include distributed fine cracking, discrete wide and deep cracking, and detachment. Distributed fine cracks appeared on the unloaded plate specimens. Discrete crack was the main failure mode on the unloaded steel sections. For the loaded long columns, the intumescent coating failure modes included both discrete crack and detachment. Intumescent coating failure affected the average temperatures attained, with average temperatures of the plate specimens, unloaded steel sections and loaded steel columns being 411°C, 472°C and 543°C respectively after 30 minutes of standard fire exposure. Different surface treatment does not seem to have much effect on fire resistance of the carbon steel columns, the two columns reaching fire resistance times of 38 and 39.5 minutes respectively.
Title: An Experimental Study of the Effects of Crack and Detachment on Insulation Properties of Intumescent Coating
Description:
AbstractThis paper presents the results of an experimental study to investigate the failure modes of intumescent coatings and their effects on temperatures attained in steel sections and load carrying capacities of steel columns.
Primer and intumescent coatings were applied to unloaded steel plates, unloaded I‐shaped short sections and axially loaded I‐shaped long columns.
For the axially loaded columns, three different surface treatments were considered.
The failure modes of intumescent coatings include distributed fine cracking, discrete wide and deep cracking, and detachment.
Distributed fine cracks appeared on the unloaded plate specimens.
Discrete crack was the main failure mode on the unloaded steel sections.
For the loaded long columns, the intumescent coating failure modes included both discrete crack and detachment.
Intumescent coating failure affected the average temperatures attained, with average temperatures of the plate specimens, unloaded steel sections and loaded steel columns being 411°C, 472°C and 543°C respectively after 30 minutes of standard fire exposure.
Different surface treatment does not seem to have much effect on fire resistance of the carbon steel columns, the two columns reaching fire resistance times of 38 and 39.
5 minutes respectively.
Related Results
Coating Processes of Pharmaceutical Applicability: A Glimpse
Coating Processes of Pharmaceutical Applicability: A Glimpse
Presentation of manuscript is aiming to furnish glimpse on coating processes. Coating is process of snugly covering substrate surface with coating materials (CoM). In due course co...
Modelling And Analysis Of Crack Turning On Aeronautical Structures
Modelling And Analysis Of Crack Turning On Aeronautical Structures
La motivació de la tesis deriva en el interès de la indústria aeronàutica a explotar, per mitjà d'un disseny adaptat, la utilització del gir d'esquerda per protegir els reforços si...
Femtosecond laser LenSx–assisted phacoemulsification of mature intumescent cataract
Femtosecond laser LenSx–assisted phacoemulsification of mature intumescent cataract
Background: Phacoemulsification (phaco) of mature intumescent cataract is one of the most difficult to perform anterior eye surgeries. In mature intumescent cataract phaco, the mos...
Effect of graphene on properties of acrylic emulsion intumescent fire retardant coating
Effect of graphene on properties of acrylic emulsion intumescent fire retardant coating
Nowadays, intumescent paint is one of the most popular fireproof paint products and is widely used in buildings. They can be applied to steel, wood, concrete, etc. This study aimed...
Optimisation of a Wet Insulation Coating for Shallow-Water Pipelines
Optimisation of a Wet Insulation Coating for Shallow-Water Pipelines
Abstract
Conventional technologies used for insulation of flowlines in shallow-water fields, based on thermoplastic foams, are over-specified for the conditions. Thi...
Expanded Polystyrene Beads Coated with Intumescent Flame Retardant Material to Achieve Fire Safety Standards
Expanded Polystyrene Beads Coated with Intumescent Flame Retardant Material to Achieve Fire Safety Standards
The compatibility and coating ratio between flame retardant materials and expanded polystyrene (EPS) foam is a major impediment to achieving satisfactory flame retardant performanc...
Thermal Intumescent Characteristics of Heated Sodium Silicate
Thermal Intumescent Characteristics of Heated Sodium Silicate
A fire barrier material is made of a rubber in which intumescent materials are mixed. Sodium silicate is one of the intumescent materials which intumesces at low temperature. In th...