Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

The Use of EDTA As a Mechanistic Probe of Magnesium Corrosion in Chloride Containing Electrolyte

View through CrossRef
Despite recent developments which have led to a better understanding of the localized corrosion behavior of magnesium (Mg) in chloride electrolyte, there are certain characteristics which remain unclear. One such aspect is the enhanced electro-catalytic activity of the dark corroded Mg surface to cathodic hydrogen evolution, previously demonstrated in several recent publications. It has also been shown that in many instances, the time-dependent Mg corrosion rate increases in proportion to the area of cathodically- activated dark surface produced in the early stages of localized corrosion propagation. It has been proposed that the effect is due to enrichment in transition metal impurity phases on the anodically attacked Mg surface. However, direct evidence of such enrichment has proved difficult, although recent reports have located iron-rich particles within the corrosion product layer (1) and interfacial Fe enrichment on a corroded Mg by Rutherford backscattering spectroscopy (2). In this work the localized corrosion of commercial purity Mg, comprising a 280 ppm Fe impurity level, is investigated in the presence and absence of ethylene diamine tetra-acetic acid (EDTA), at different concentrations and pH values, when immersed in aqueous sodium chloride electrolyte. The aim of the investigation is to exploit the ability of EDTA to act as a chelating agent for Mg2+ and transition metal ions such as Fe2+, so that the principal influencing factors causing the propagation of cathodically activated dark regions on corroding Mg may be identified.  The presence of EDTA in 1 mol dm-3 NaCl (aq) at pH 6 is shown to markedly decrease the rate of Mg corrosion in freely corroding conditions, as shown by the plots of time dependent hydrogen evolution (HE) given in Figure 1. Increasing the concentration of EDTA progressively reduces the rate of HE and produces a change in kinetics, where a monotonic increase in the quantity of hydrogen evolved with time is observed. This is in contrast to the exponential relationship seen over the first 60 min immersion for the control experiment and at a lower EDTA concentration.  The decrease in corrosion rate is accompanied by a significant change in the visual appearance of the corroding surface. Although dark, expanding circular corrosion features propagate in the presence of 10-3 mol dm-3EDTA, no such behavior is observed when the concentration is increased by an order of magnitude, and the exposed surface remains covered by a cloudy white film. In-situ SVET shows no evidence of localized corrosion patterns characteristic of the un-inhibited case even over protracted immersion times of several hours. Similar observations are observed at higher pH although the influence of EDTA on bulk rates of HE are not as marked when compared to the control case. In separate experiments, where localized corrosion is allowed to propagate before EDTA addition to the corrosive electrolyte, significant changes in current density patterns are observed at the point of addition. This is shown in Figure 2, where EDTA halts propagation and the intense local anodic activity observed at the perimeter of the corroded area becomes displaced to the remaining intact (uncorroded) surface, although at significantly lower current density values. The observations of a strongly mitigated HE rate seem to be inconsistent with a scenario where EDTA complexation of Mg2+ ions prevents deposition of surface corrosion product. A theory is proposed to explain the action of EDTA in terms of its ability to strongly chelate Fe2+, possibly present in the direct vicinity of the corroding Mg surface, in a situation where Fe-rich impurity phases become detached from the matrix and corrode independently of the matrix. The possibility of subsequent re-plating of Fe onto the corroding Mg to produce an electro-catalytically activated surface is considered. The acceleration of HE rates from corroding Mg surfaces on which iron re-plating has taken place is confirmed by experimentation.  References 1. M. Taheri, J. R. Kish, N. Birbilis, M. Danaie, E. A. McNally, and J. R. McDermid, Electrochim Acta, 116, 396 (2014). 2. T. Cain, S. B. Madden, N. Birbilis and J. R. Scully, J. Electrochem. Soc., 162, C228 (2015). Figure 1: Time-dependent hydrogen evolution observed for CP-Mg (280 ppm Fe) immersed in 1 mol dm-3 NaCl at pH 6, in the absence (i) and presence of EDTA additions at concentrations of (ii) 10-3 and (iii) 10-2 mol dm-3. Figure 2: SVET derived current density distribution maps obtained for freely-corroding CP-Mg in 1 mol dm-3 NaCl (aq) at pH10 after immersion for (i) 1h and (ii) immediately after the addition of 0.1 mol dm-3 EDTA to the electrolyte. Figure 1
Title: The Use of EDTA As a Mechanistic Probe of Magnesium Corrosion in Chloride Containing Electrolyte
Description:
Despite recent developments which have led to a better understanding of the localized corrosion behavior of magnesium (Mg) in chloride electrolyte, there are certain characteristics which remain unclear.
One such aspect is the enhanced electro-catalytic activity of the dark corroded Mg surface to cathodic hydrogen evolution, previously demonstrated in several recent publications.
It has also been shown that in many instances, the time-dependent Mg corrosion rate increases in proportion to the area of cathodically- activated dark surface produced in the early stages of localized corrosion propagation.
It has been proposed that the effect is due to enrichment in transition metal impurity phases on the anodically attacked Mg surface.
However, direct evidence of such enrichment has proved difficult, although recent reports have located iron-rich particles within the corrosion product layer (1) and interfacial Fe enrichment on a corroded Mg by Rutherford backscattering spectroscopy (2).
In this work the localized corrosion of commercial purity Mg, comprising a 280 ppm Fe impurity level, is investigated in the presence and absence of ethylene diamine tetra-acetic acid (EDTA), at different concentrations and pH values, when immersed in aqueous sodium chloride electrolyte.
The aim of the investigation is to exploit the ability of EDTA to act as a chelating agent for Mg2+ and transition metal ions such as Fe2+, so that the principal influencing factors causing the propagation of cathodically activated dark regions on corroding Mg may be identified.
 The presence of EDTA in 1 mol dm-3 NaCl (aq) at pH 6 is shown to markedly decrease the rate of Mg corrosion in freely corroding conditions, as shown by the plots of time dependent hydrogen evolution (HE) given in Figure 1.
Increasing the concentration of EDTA progressively reduces the rate of HE and produces a change in kinetics, where a monotonic increase in the quantity of hydrogen evolved with time is observed.
This is in contrast to the exponential relationship seen over the first 60 min immersion for the control experiment and at a lower EDTA concentration.
 The decrease in corrosion rate is accompanied by a significant change in the visual appearance of the corroding surface.
Although dark, expanding circular corrosion features propagate in the presence of 10-3 mol dm-3EDTA, no such behavior is observed when the concentration is increased by an order of magnitude, and the exposed surface remains covered by a cloudy white film.
In-situ SVET shows no evidence of localized corrosion patterns characteristic of the un-inhibited case even over protracted immersion times of several hours.
Similar observations are observed at higher pH although the influence of EDTA on bulk rates of HE are not as marked when compared to the control case.
In separate experiments, where localized corrosion is allowed to propagate before EDTA addition to the corrosive electrolyte, significant changes in current density patterns are observed at the point of addition.
This is shown in Figure 2, where EDTA halts propagation and the intense local anodic activity observed at the perimeter of the corroded area becomes displaced to the remaining intact (uncorroded) surface, although at significantly lower current density values.
The observations of a strongly mitigated HE rate seem to be inconsistent with a scenario where EDTA complexation of Mg2+ ions prevents deposition of surface corrosion product.
A theory is proposed to explain the action of EDTA in terms of its ability to strongly chelate Fe2+, possibly present in the direct vicinity of the corroding Mg surface, in a situation where Fe-rich impurity phases become detached from the matrix and corrode independently of the matrix.
The possibility of subsequent re-plating of Fe onto the corroding Mg to produce an electro-catalytically activated surface is considered.
The acceleration of HE rates from corroding Mg surfaces on which iron re-plating has taken place is confirmed by experimentation.
 References 1.
M.
Taheri, J.
R.
Kish, N.
Birbilis, M.
Danaie, E.
A.
McNally, and J.
R.
McDermid, Electrochim Acta, 116, 396 (2014).
2.
T.
Cain, S.
B.
Madden, N.
Birbilis and J.
R.
Scully, J.
Electrochem.
Soc.
, 162, C228 (2015).
Figure 1: Time-dependent hydrogen evolution observed for CP-Mg (280 ppm Fe) immersed in 1 mol dm-3 NaCl at pH 6, in the absence (i) and presence of EDTA additions at concentrations of (ii) 10-3 and (iii) 10-2 mol dm-3.
Figure 2: SVET derived current density distribution maps obtained for freely-corroding CP-Mg in 1 mol dm-3 NaCl (aq) at pH10 after immersion for (i) 1h and (ii) immediately after the addition of 0.
1 mol dm-3 EDTA to the electrolyte.
Figure 1.

Related Results

Investigating the Effect of High Pressures and Temperatures on Corrosion Inhibition for Water-Based Muds
Investigating the Effect of High Pressures and Temperatures on Corrosion Inhibition for Water-Based Muds
Corrosion is defined as gradual degradation of metal caused by a chemical or electrochemical reaction with its environment. In oil and gas sector, components can corrode at any sta...
ผลของตัวคีเลตต่อการสะสมแคดเมียมของทานตะวัน Helianthus annuus Linn.
ผลของตัวคีเลตต่อการสะสมแคดเมียมของทานตะวัน Helianthus annuus Linn.
การศึกษาผลของคีเลตต่อการสะสมแคดเมียมของทานตะวัน (Helianthus annuus Linn.) โดยการปลูกทานตะวันในกระถางทดลองที่เติมสารละลายแคดเมียมไนเตรต (Cd(NO[subscript 3])[subscript 2]4H[subscript...
PROTECTIVE ABILITY OF TIN-NICKEL COATINGS
PROTECTIVE ABILITY OF TIN-NICKEL COATINGS
The calculation of the corrosion current of the steel – plating allowed us to estimate the protective properties and the porosity of the Tin-Nickel coatings. Measured in 3% NaCl so...
Resource-efficient technology for the utilization of serpentine technogenic waste with the production of magnesium oxide
Resource-efficient technology for the utilization of serpentine technogenic waste with the production of magnesium oxide
The article discusses the possibility of using serpentine and serpentine waste from Zhitikara deposit for the production of inorganic magnesium compounds: MgSO4, Mg(OH)2 and MgO. T...
Improved organic coating delamination resistance using physical vapour deposited Zn-Mg layers on strip steel
Improved organic coating delamination resistance using physical vapour deposited Zn-Mg layers on strip steel
Physical vapour deposition (PVD) of zinc alloy coatings was investigated as a potential substitute process for commercially available hot dip galvanising (HDG) of strip steel. Ther...
Impact of Common Anticoagulants on Complete Blood Count Parameters Among Humans
Impact of Common Anticoagulants on Complete Blood Count Parameters Among Humans
Abstract Introduction Among the most frequently used anticoagulants in hematological testing are tetra-acetic acid (EDTA), sodium citrate, and sodium heparin. However, there is a n...
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
What is the Proper Composition of the Dialysate Magnesium and How Much Magnesium is Removed During Pre-Dilution Online Hemodiafiltration?
What is the Proper Composition of the Dialysate Magnesium and How Much Magnesium is Removed During Pre-Dilution Online Hemodiafiltration?
Aim: The aim of the study was to determine the ideal dialysate magnesium during hemodialysis, knowing that the solution used is not satisfactory and is often associated with low se...

Back to Top