Retinoscopy in Infants Using a Near Noncycloplegic Technique, Cycloplegia with Tropicamide 1%, and Cycloplegia with Cyclopentolate 1%
View through CrossRef
Purpose.
This study compares retinoscopy in infants using a near noncycloplegic technique, cycloplegia with tropicamide 1%, and cycloplegia with cyclopentolate 1%. The study sample included 29 healthy, nonstrabismic infants 4 to 7 months of age (mean 5.71 months).
Methods.
Each study subject was examined at two separate visits an average of 2 weeks apart (mean [±SD] 14 ± 9 days). The examiner completed a case history, iris color grading, confrontation tests, and noncycloplegic near retinoscopy in a dark room and then instilled a drop of topical anesthetic in each eye followed by 2 drops of cycloplegic agent separated by 5 min. Retinoscopy was performed 25 to 30 min after the first drops were instilled. The bottles were masked, and the drop administered at the first visit was randomly assigned.
Results.
On a scale of 0 to 4.9, the median iris grade was 4.0, which corresponds to a brown or darkly pigmented iris. All reported retinoscopy results are for the horizontal meridian of the right eye. The mean refractive error using noncycloplegic near retinoscopy was +0.94 D (±1.19 D). The mean refractive error was +1.81 D (±1.19 D) with tropicamide and +1.88 D (±1.45 D) with cyclopentolate. There was no statistically or clinically significant difference between the two cycloplegic measurements using different diagnostic agents (t = −0.46, p = 0.65). The mean difference between noncycloplegic and cycloplegic retinoscopy was 0.89 D (±0.66 D) with tropicamide (t = −6.57, p < 0.0001) and 1.04 D (±0.94 D) with cyclopentolate (t = −5.38, p < 0.0001; all two‐sided paired t‐tests). There were no serious adverse reactions with either agent, although one infant temporarily developed redder than normal cheeks after instillation of cyclopentolate.
Conclusion.
Our results suggest that tropicamide is as effective as cyclopentolate for the measurement of refractive error in most healthy, nonstrabismic infants.
Title: Retinoscopy in Infants Using a Near Noncycloplegic Technique, Cycloplegia with Tropicamide 1%, and Cycloplegia with Cyclopentolate 1%
Description:
Purpose.
This study compares retinoscopy in infants using a near noncycloplegic technique, cycloplegia with tropicamide 1%, and cycloplegia with cyclopentolate 1%.
The study sample included 29 healthy, nonstrabismic infants 4 to 7 months of age (mean 5.
71 months).
Methods.
Each study subject was examined at two separate visits an average of 2 weeks apart (mean [±SD] 14 ± 9 days).
The examiner completed a case history, iris color grading, confrontation tests, and noncycloplegic near retinoscopy in a dark room and then instilled a drop of topical anesthetic in each eye followed by 2 drops of cycloplegic agent separated by 5 min.
Retinoscopy was performed 25 to 30 min after the first drops were instilled.
The bottles were masked, and the drop administered at the first visit was randomly assigned.
Results.
On a scale of 0 to 4.
9, the median iris grade was 4.
0, which corresponds to a brown or darkly pigmented iris.
All reported retinoscopy results are for the horizontal meridian of the right eye.
The mean refractive error using noncycloplegic near retinoscopy was +0.
94 D (±1.
19 D).
The mean refractive error was +1.
81 D (±1.
19 D) with tropicamide and +1.
88 D (±1.
45 D) with cyclopentolate.
There was no statistically or clinically significant difference between the two cycloplegic measurements using different diagnostic agents (t = −0.
46, p = 0.
65).
The mean difference between noncycloplegic and cycloplegic retinoscopy was 0.
89 D (±0.
66 D) with tropicamide (t = −6.
57, p < 0.
0001) and 1.
04 D (±0.
94 D) with cyclopentolate (t = −5.
38, p < 0.
0001; all two‐sided paired t‐tests).
There were no serious adverse reactions with either agent, although one infant temporarily developed redder than normal cheeks after instillation of cyclopentolate.
Conclusion.
Our results suggest that tropicamide is as effective as cyclopentolate for the measurement of refractive error in most healthy, nonstrabismic infants.
Related Results
COMPARISON OF ACUTE EFFECT OF CYCLOPENTOLATE AND TROPICAMIDE ON INTRAOCULAR PRESSURE ON ALBINO RABBITS
COMPARISON OF ACUTE EFFECT OF CYCLOPENTOLATE AND TROPICAMIDE ON INTRAOCULAR PRESSURE ON ALBINO RABBITS
Cycloplegic agents like cyclopentolate and tropicamide eyedrops are broadly used in optometric exams to dilate pupils and temporarily stop accommodation. However, they can cause sl...
CYCLOPENTOLATE VERSUS TROPICAMIDE AND CYCLOPENTOLATE IN LIBYAN CHILDREN
CYCLOPENTOLATE VERSUS TROPICAMIDE AND CYCLOPENTOLATE IN LIBYAN CHILDREN
The young children have very strong ciliary muscle tone, that need cycloplegic agents to paralyze it, which done by instilling of cycloplegic eye drop. As eye drop usage in young i...
Cardiovascular Malformations Among Preterm Infants
Cardiovascular Malformations Among Preterm Infants
Objective. Preterm birth and cardiovascular malformations are the 2 most common causes of neonatal and infant death, but there are no published population-based reports on the rela...
Pediatric cycloplegic refraction
Pediatric cycloplegic refraction
Background: Cycloplegic refraction is an essential part of the pediatric ophthalmic assessment and is the cornerstone of strabismus evaluation. This narrative review aimed to ascer...
COMPARISON BETWEEN AUTOREFRACTION AND RETINOSCOPY FOR SUBJECTIVE CORRECTION IN CHILDREN
COMPARISON BETWEEN AUTOREFRACTION AND RETINOSCOPY FOR SUBJECTIVE CORRECTION IN CHILDREN
The study's objective was to compare the accuracy of retinoscopy and autorefraction for subjective correction in children. The study was conducted in the Department of Ophthalmolog...
The impact of accommodation function on the difference between noncycloplegic and cycloplegic refraction in adult myopes
The impact of accommodation function on the difference between noncycloplegic and cycloplegic refraction in adult myopes
AbstractPurposeTo investigate the impact of accommodation function on the difference between cycloplegic and noncycloplegic subjective and automatic refraction in adult myopes.Meth...
Accuracy of Concave Sleeve in Comparison with Plano Sleeve While Doing Retinoscopy
Accuracy of Concave Sleeve in Comparison with Plano Sleeve While Doing Retinoscopy
Background: One of the main reasons for a reduction in visual acuity is refractive error. It can either be determined by using different devices or by placing corrective lenses in ...