Javascript must be enabled to continue!
Accuracy of Concave Sleeve in Comparison with Plano Sleeve While Doing Retinoscopy
View through CrossRef
Background: One of the main reasons for a reduction in visual acuity is refractive error. It can either be determined by using different devices or by placing corrective lenses in front of the eye and asking questions. Objective: To evaluate the accuracy of the concave sleeve in comparison with the plano sleeve while performing retinoscopy. Methodology: This was a cross-sectional comparative study in which 43 patients visiting Mayo Hospital for ocular examination were recruited. Patients above 15 years of either sex were included. Patients with any other external ocular disease were excluded from the study. Data was collected by using a self-designed proforma which included information about patient profile, previous ocular history, type of refractive error, and concave sleeve reading and plano sleeve reading of retinoscopy. College of Ophthalmology and Allied Vision Sciences, Lahore. The study was conducted from September to December 2021. All the data was entered and analysed by using the statistical package for the social sciences (SPSS version 25.00). Descriptive statistics were used for quantitative data, such as standard deviation and mean. Interclass correlation was applied to compare both groups. Paired sample T-test was applied for the mean value. Retinoscopy with plano and concave sleeves was performed in each individual. Results of both techniques were analysed by the interclass correlation method. Plano sleeve retinoscopy was performed first in a dark room, and a distance target was given to the patient. After performing plano sleeve retinoscopy, concave sleeve retinoscopy was performed. The final prescription was adjusted by subtracting the working distance of 1.5D. Results: Results were taken from a self-designed proforma using the Interclass Correlation method. Interclass correlation value of spherical equivalent of concave and plano sleeve was strong and positive (ICC = 0.863). Concave and Plano sleeve of retinoscopy were performed in each individual. There was no significant difference between the accuracy of the two sleeves. (p-value=0.26). Conclusion: Concave sleeve and plano sleeve have the same accuracy in measuring refractive error with retinoscopy, and there is no significant difference between the accuracy of both sleeves.
Physio Rehab and Research Center Pvt Ltd
Title: Accuracy of Concave Sleeve in Comparison with Plano Sleeve While Doing Retinoscopy
Description:
Background: One of the main reasons for a reduction in visual acuity is refractive error.
It can either be determined by using different devices or by placing corrective lenses in front of the eye and asking questions.
Objective: To evaluate the accuracy of the concave sleeve in comparison with the plano sleeve while performing retinoscopy.
Methodology: This was a cross-sectional comparative study in which 43 patients visiting Mayo Hospital for ocular examination were recruited.
Patients above 15 years of either sex were included.
Patients with any other external ocular disease were excluded from the study.
Data was collected by using a self-designed proforma which included information about patient profile, previous ocular history, type of refractive error, and concave sleeve reading and plano sleeve reading of retinoscopy.
College of Ophthalmology and Allied Vision Sciences, Lahore.
The study was conducted from September to December 2021.
All the data was entered and analysed by using the statistical package for the social sciences (SPSS version 25.
00).
Descriptive statistics were used for quantitative data, such as standard deviation and mean.
Interclass correlation was applied to compare both groups.
Paired sample T-test was applied for the mean value.
Retinoscopy with plano and concave sleeves was performed in each individual.
Results of both techniques were analysed by the interclass correlation method.
Plano sleeve retinoscopy was performed first in a dark room, and a distance target was given to the patient.
After performing plano sleeve retinoscopy, concave sleeve retinoscopy was performed.
The final prescription was adjusted by subtracting the working distance of 1.
5D.
Results: Results were taken from a self-designed proforma using the Interclass Correlation method.
Interclass correlation value of spherical equivalent of concave and plano sleeve was strong and positive (ICC = 0.
863).
Concave and Plano sleeve of retinoscopy were performed in each individual.
There was no significant difference between the accuracy of the two sleeves.
(p-value=0.
26).
Conclusion: Concave sleeve and plano sleeve have the same accuracy in measuring refractive error with retinoscopy, and there is no significant difference between the accuracy of both sleeves.
.
Related Results
COMPARISON BETWEEN AUTOREFRACTION AND RETINOSCOPY FOR SUBJECTIVE CORRECTION IN CHILDREN
COMPARISON BETWEEN AUTOREFRACTION AND RETINOSCOPY FOR SUBJECTIVE CORRECTION IN CHILDREN
The study's objective was to compare the accuracy of retinoscopy and autorefraction for subjective correction in children. The study was conducted in the Department of Ophthalmolog...
Determination of effective riser sleeve thermophysical properties for simulation and analysis of riser sleeve performance
Determination of effective riser sleeve thermophysical properties for simulation and analysis of riser sleeve performance
<p>Riser sleeve thermophysical properties for simulation are developed using an inverse modeling technique. Casting experiments using riser sleeves are performed in order to ...
Technology of preparation of sleeve ends before pilgrims rolling
Technology of preparation of sleeve ends before pilgrims rolling
The paper considers the issues of improvement of hot pilgrim rolling of pipes by means of preparation of front and rear ends of sleeves. The presence of a gap between the sleeve an...
Retinoscopy in Infants Using a Near Noncycloplegic Technique, Cycloplegia with Tropicamide 1%, and Cycloplegia with Cyclopentolate 1%
Retinoscopy in Infants Using a Near Noncycloplegic Technique, Cycloplegia with Tropicamide 1%, and Cycloplegia with Cyclopentolate 1%
Purpose.
This study compares retinoscopy in infants using a near noncycloplegic technique, cycloplegia with tropicamide 1%, and cycloplegia with cyclopentolate ...
L-(resp. concave) down-directed convergence relation spaces and L-(resp. concave) filter convergence spaces
L-(resp. concave) down-directed convergence relation spaces and L-(resp. concave) filter convergence spaces
Convergence structure and relation are useful tools in interpreting many
mathematical structures such as topological spaces and convex spaces. The
aim of this paper is to stu...
Comparison of the accuracy of implant placement between using sleeve-in-sleeve and integrated sleeve-on-drill drilling systems for static computer-assisted implant surgery: a simulation-based experimental study
Comparison of the accuracy of implant placement between using sleeve-in-sleeve and integrated sleeve-on-drill drilling systems for static computer-assisted implant surgery: a simulation-based experimental study
Objective: To investigate precision of implant placement with sleeve-in-sleeve and sleeve-on-drill static Computer Assisted Implant Surgery (sCAIS) designs.
Materials and Methods:...
A Comprehensive New Look at Type B Sleeves
A Comprehensive New Look at Type B Sleeves
Abstract
Type B full encirclement steel sleeves have been used for the past fifty-plus years as a viable repair method for most, if not all, features encountered on ...
Comparative evaluation on wear resistance of metal sleeve, sleeve-free resin, and reinforced sleeve-free resin implant guide: An in vitro study
Comparative evaluation on wear resistance of metal sleeve, sleeve-free resin, and reinforced sleeve-free resin implant guide: An in vitro study
Background:
In-office three-dimensional (3D) printers and metal sleeveless surgical guides are becoming a major trend recently. However, metal sleeve-free designs are r...