Javascript must be enabled to continue!
Utility of cardiovascular magnetic resonance in patients with stable troponin elevation
View through CrossRef
Abstract
Aims
Cardiovascular magnetic resonance (CMR) imaging has a potential role in the evaluation of symptomatic patients with stable troponin elevation; however, its utility remains unexplored. We sought to determine the incremental diagnostic value of CMR in this unique cohort and assess the long-term clinical outcomes.
Methods and results
Two hundred twenty-five consecutive patients presenting with cardiac chest pain/dyspnoea, stable troponin elevation, and undergoing CMR assessment were identified retrospectively from registry database. The study cohort was prospectively followed for major adverse cardiac events (MACEs) (defined as composite of all-cause mortality and cardiovascular readmissions). The primary outcome measure was the diagnostic utility of CMR, i.e. percentage of patients for whom CMR identified the cause of stable troponin elevation. Secondary outcome measures included the incremental value of CMR and occurrence of MACE. CMR was able to identify the cause for stable troponin elevation in 160 (71%) patients. A normal CMR was identified in 17% and an inconclusive CMR in 12% of the patients. CMR changed the referral diagnosis in 59 (26%) patients. Utilizing a baseline prediction model (pre-CMR referral diagnosis), the net reclassification index was 0.11 and integrated discriminatory improvement index measured 0.33 following CMR. Over a median follow-up of 4.3 years (interquartile range 2.8–6.3), 72 (32%) patients experienced MACE.
Conclusion
CMR identified a cause for stable troponin elevation in 7 of 10 cases, and a new diagnosis was evident in 1 of 4 cases. CMR improved the net reclassification of patients with stable troponin elevation.
Title: Utility of cardiovascular magnetic resonance in patients with stable troponin elevation
Description:
Abstract
Aims
Cardiovascular magnetic resonance (CMR) imaging has a potential role in the evaluation of symptomatic patients with stable troponin elevation; however, its utility remains unexplored.
We sought to determine the incremental diagnostic value of CMR in this unique cohort and assess the long-term clinical outcomes.
Methods and results
Two hundred twenty-five consecutive patients presenting with cardiac chest pain/dyspnoea, stable troponin elevation, and undergoing CMR assessment were identified retrospectively from registry database.
The study cohort was prospectively followed for major adverse cardiac events (MACEs) (defined as composite of all-cause mortality and cardiovascular readmissions).
The primary outcome measure was the diagnostic utility of CMR, i.
e.
percentage of patients for whom CMR identified the cause of stable troponin elevation.
Secondary outcome measures included the incremental value of CMR and occurrence of MACE.
CMR was able to identify the cause for stable troponin elevation in 160 (71%) patients.
A normal CMR was identified in 17% and an inconclusive CMR in 12% of the patients.
CMR changed the referral diagnosis in 59 (26%) patients.
Utilizing a baseline prediction model (pre-CMR referral diagnosis), the net reclassification index was 0.
11 and integrated discriminatory improvement index measured 0.
33 following CMR.
Over a median follow-up of 4.
3 years (interquartile range 2.
8–6.
3), 72 (32%) patients experienced MACE.
Conclusion
CMR identified a cause for stable troponin elevation in 7 of 10 cases, and a new diagnosis was evident in 1 of 4 cases.
CMR improved the net reclassification of patients with stable troponin elevation.
Related Results
Detectable troponin below the 99th percentile predicts survival in patients with cardiovascular disease
Detectable troponin below the 99th percentile predicts survival in patients with cardiovascular disease
Abstract
Background
Patients with cardiovascular disease and elevated troponin above the 99th percentile of the upper reference ...
Prevalence and Outcomes of Cardiovascular Diseases in Patients with COVID-19: A Research Letter
Prevalence and Outcomes of Cardiovascular Diseases in Patients with COVID-19: A Research Letter
Introduction
A higher prevalence of cardiovascular diseases among COVID-19 with positive troponin levels was initially observed in China beginning of the pandemic era. We are tryin...
Additional PKA phosphorylation sites in human cardiac troponin I
Additional PKA phosphorylation sites in human cardiac troponin I
We used mass spectrometry to monitor cAMP‐dependent protein kinase catalysed phosphorylation of human cardiac troponin I in vitro. Phosphorylation of isolated troponin I by cAMP‐de...
Structural dynamics of the intrinsically disordered linker region of cardiac troponin T
Structural dynamics of the intrinsically disordered linker region of cardiac troponin T
ABSTRACT
The cardiac troponin complex, composed of troponins I, T, and C, plays a central role in regulating the calcium-dependent interactions between myosin and t...
Phosphorylation of troponin and the effects of interactions between the components of the complex
Phosphorylation of troponin and the effects of interactions between the components of the complex
1. The troponin complex from skeletal muscle contains approximately 1 mol of phosphate/80000g of complex, covalently bound to the troponin T component. 2. On prolonged incubation o...
Frequency and outcome of elevated troponin level in patients presenting with acute ischemic stroke at a tertiary care hospital, Karachi
Frequency and outcome of elevated troponin level in patients presenting with acute ischemic stroke at a tertiary care hospital, Karachi
Background: Heart troponin has been observed to be raised in patients with acute ischemic stroke (AIS); its prognosis is controversial. The aim of this study was to review the inci...
The phosphorylation of troponin I from cardiac muscle
The phosphorylation of troponin I from cardiac muscle
1. Troponin I isolated from fresh cardiac muscle by affinity chromatography contains about 1.9 mol of covalently bound phosphate/mol. Similar preparations of white-skeletal-muscle ...
Analysis of the causes of discrepancies in troponin I concentrations as measured by ARCHITECT High-Sensitive Troponin I ST and STACIA CLEIA cTnI
Analysis of the causes of discrepancies in troponin I concentrations as measured by ARCHITECT High-Sensitive Troponin I ST and STACIA CLEIA cTnI
Background
Recently developed reagents for the highly sensitive measurement of cardiac troponin I are useful for early diagnosis of acute coronary syndrome. How...

