Comparison of Abdominal Aorta Palpation With Ultrasound Imaging Measurements in Healthy Individuals
View through CrossRef
Purpose:
Palpation is a traditional physical exam tool used to screen for abdominal aorta aneurysm. The purpose of this study was to determine agreement and reliability of abdominal aorta palpation measurements compared to point of care ultrasound (POCUS) measurements by novice physical therapy examiners in healthy individuals.
Methods:
Fifty healthy subjects over age 18 participated (age 25.2 ± 3.4). Two novice physical therapy examiners, blinded to each other's findings, measured infrarenal abdominal aorta width using a two-finger palpation technique and with POCUS, using a Vscan Air™ handheld ultrasound device, in randomized order. Bland–Altman analysis and paired t-tests compared agreement between palpation and POCUS measurements. Twenty-five participants returned within a month to assess intrarater reliability.
Results:
POCUS abdominal aorta width measurements averaged 1.54 cm (SD = 0.21), whereas palpation measurements averaged 2.51 cm (SD = 1.07), with a mean difference of 0.97 cm (SD = 1.03; 95% CI [0.67, 1.26]; P < .001). Palpation and POCUS measurements showed a positive correlation of 0.319 (P = .025); however, agreement decreased as aorta size increased. Intrarater reliability for POCUS had an intraclass correlation coefficient (ICC) of 0.58 (95% CI [0.25, 0.79]), and palpation showed intrarater reliability ICC of 0.59 (95% CI [0.25, 0.80]).
Conclusions:
Palpation overestimates infrarenal abdominal aorta width compared to POCUS in healthy individuals when performed by novice physical therapy examiners. While moderate agreement with POCUS exists, palpation accuracy decreases as aorta size increases, showing more variability. Further validation is needed in physical therapy examiners with more experience and in individuals with abdominal aortic aneurysm.
Ovid Technologies (Wolters Kluwer Health)
Title: Comparison of Abdominal Aorta Palpation With Ultrasound Imaging Measurements in Healthy Individuals
Description:
Purpose:
Palpation is a traditional physical exam tool used to screen for abdominal aorta aneurysm.
The purpose of this study was to determine agreement and reliability of abdominal aorta palpation measurements compared to point of care ultrasound (POCUS) measurements by novice physical therapy examiners in healthy individuals.
Methods:
Fifty healthy subjects over age 18 participated (age 25.
2 ± 3.
4).
Two novice physical therapy examiners, blinded to each other's findings, measured infrarenal abdominal aorta width using a two-finger palpation technique and with POCUS, using a Vscan Air™ handheld ultrasound device, in randomized order.
Bland–Altman analysis and paired t-tests compared agreement between palpation and POCUS measurements.
Twenty-five participants returned within a month to assess intrarater reliability.
Results:
POCUS abdominal aorta width measurements averaged 1.
54 cm (SD = 0.
21), whereas palpation measurements averaged 2.
51 cm (SD = 1.
07), with a mean difference of 0.
97 cm (SD = 1.
03; 95% CI [0.
67, 1.
26]; P < .
001).
Palpation and POCUS measurements showed a positive correlation of 0.
319 (P = .
025); however, agreement decreased as aorta size increased.
Intrarater reliability for POCUS had an intraclass correlation coefficient (ICC) of 0.
58 (95% CI [0.
25, 0.
79]), and palpation showed intrarater reliability ICC of 0.
59 (95% CI [0.
25, 0.
80]).
Conclusions:
Palpation overestimates infrarenal abdominal aorta width compared to POCUS in healthy individuals when performed by novice physical therapy examiners.
While moderate agreement with POCUS exists, palpation accuracy decreases as aorta size increases, showing more variability.
Further validation is needed in physical therapy examiners with more experience and in individuals with abdominal aortic aneurysm.
Related Results
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract
Introduction
Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...
Atypical Sigmoid Volvulus in an Adolescent: A Case Report and Literature Review
Atypical Sigmoid Volvulus in an Adolescent: A Case Report and Literature Review
Abstract
Introduction
Sigmoid volvulus is an underrecognized diagnosis with potentially fatal outcomes in adolescents; the current study aims to present an adolescent with mild sym...
Renal Ewing Sarcoma: A Case Report and Literature Review
Renal Ewing Sarcoma: A Case Report and Literature Review
Abstract
Introduction
Primary renal Ewing sarcoma is an extremely rare and aggressive tumor, representing less than 1% of all renal tumors. This case report contributes valuable in...
Assessment of Abdominal Aorta Diameter on Contrast-enhanced Computed Tomography: A MDCT-based Observational Study
Assessment of Abdominal Aorta Diameter on Contrast-enhanced Computed Tomography: A MDCT-based Observational Study
Introduction: Average size of the abdominal aorta is less than 3 cm which variates with time. The increase in abdominal aortic dimensions more than 3 cm can result in the presence ...
Assessment of Normal Diameter of Thoracic Aorta Using Computed Tomography Angiography
Assessment of Normal Diameter of Thoracic Aorta Using Computed Tomography Angiography
ObjectiveThis retrospectiv study aimed to asses normal diameter of the thoracic aorta in the healthy Sudanese population using Computed Tomography AngiographyMaterial and MethodAto...
PLACE DE L’IMAGERIE DANS LE DIAGNOSTIC DES DOULEURS ABDOMINALES AIGUËS DE L’ADULTE AUX URGENCES CHIRURGICALES DE L’HOPITAL ARISTIDE LE DANTEC
PLACE DE L’IMAGERIE DANS LE DIAGNOSTIC DES DOULEURS ABDOMINALES AIGUËS DE L’ADULTE AUX URGENCES CHIRURGICALES DE L’HOPITAL ARISTIDE LE DANTEC
Aim : To report the imaging strategies in the diagnosis of acute non-traumatic acute abdominal pain in adult patient. Patients and methods: We performed aforward-looking study over...
Diagnostic performance of peripheral nerve palpation compared with ultrasonography in leprosy neuropathy: A prospective real-world clinical evaluation
Diagnostic performance of peripheral nerve palpation compared with ultrasonography in leprosy neuropathy: A prospective real-world clinical evaluation
Background
Leprosy frequently causes peripheral neuropathy, and nerve palpation remains a cornerstone of diagnosis in many endemic settings despite its subjecti...
Manajemen Syok Kardiogenik pada Diseksi Aorta
Manajemen Syok Kardiogenik pada Diseksi Aorta
<p>Pendahuluan: Diseksi aorta merupakan kegawat daruratan akibat robekan tunika intima aorta yang menyebabkan perdarahan ke dalam tunika media. Komplikasi syok terjadi pada l...