Javascript must be enabled to continue!
Are Magnesium Screws Proper for Mandibular Condyle Head Osteosynthesis?
View through CrossRef
Recently, magnesium alloys have gained a significant amount of recognition as potential biomaterials for degradable implants for craniofacial bone screws. Purpose: The aim of this work was to compare screws made specifically for mandibular head osteosynthesis from different materials. Materials and Methods: Screws measuring 14 mm made by one manufacturer specifically for mandibular head osteosynthesis out of the following materials were selected: magnesium (MgYREZr), titanium (Ti6Al7Nb), and polymer (PLGA). The axial pull-out strength and torsional properties were investigated. Results: Each type of screw presented different pull-out forces (Kruskal–Wallis test, p < 0.001). The magnesium screw had the highest pull-out force of 399 N (cracked without the screw out being pulled out), followed by the titanium screw, with a force of 340 N, and the PLGA screw, with a force of 138 N (always cracked at the base of the screw head without the screw being pulled out). ANOVA was performed for the maximal torques before damage to the screw (torsional properties), revealing that the maximal torque of the magnesium screw was 16 N·cm, while that of the titanium screw was 19 N·cm. The magnesium screw was significantly weaker than the titanium screw (p < 0.05). The measured torque and pull-out force were not related to each other (p > 0.05). Conclusion: Among the screws compared, the metal biodegradable magnesium screw seems to be the most suitable material for multiscrew mandibular head osteosynthesis, considering the condition of the fragile screwdriver socket.
Title: Are Magnesium Screws Proper for Mandibular Condyle Head Osteosynthesis?
Description:
Recently, magnesium alloys have gained a significant amount of recognition as potential biomaterials for degradable implants for craniofacial bone screws.
Purpose: The aim of this work was to compare screws made specifically for mandibular head osteosynthesis from different materials.
Materials and Methods: Screws measuring 14 mm made by one manufacturer specifically for mandibular head osteosynthesis out of the following materials were selected: magnesium (MgYREZr), titanium (Ti6Al7Nb), and polymer (PLGA).
The axial pull-out strength and torsional properties were investigated.
Results: Each type of screw presented different pull-out forces (Kruskal–Wallis test, p < 0.
001).
The magnesium screw had the highest pull-out force of 399 N (cracked without the screw out being pulled out), followed by the titanium screw, with a force of 340 N, and the PLGA screw, with a force of 138 N (always cracked at the base of the screw head without the screw being pulled out).
ANOVA was performed for the maximal torques before damage to the screw (torsional properties), revealing that the maximal torque of the magnesium screw was 16 N·cm, while that of the titanium screw was 19 N·cm.
The magnesium screw was significantly weaker than the titanium screw (p < 0.
05).
The measured torque and pull-out force were not related to each other (p > 0.
05).
Conclusion: Among the screws compared, the metal biodegradable magnesium screw seems to be the most suitable material for multiscrew mandibular head osteosynthesis, considering the condition of the fragile screwdriver socket.
Related Results
Three Dimensional Evaluation of Changes in Mandibular Condyle Position After Orthognathic Surgery
Three Dimensional Evaluation of Changes in Mandibular Condyle Position After Orthognathic Surgery
Abstract
Background: This study aims to examine the changes in both mandibular condyle positions before and after surgery to evaluate manual temporomandibular joint (TMJ) p...
Bilateral bifid condyle mandibula features in panoramic radiography: a case report
Bilateral bifid condyle mandibula features in panoramic radiography: a case report
Objectives: The aim of this case report is to describe radiographically the specific features of bifid mandibular condyle that frequently found incidentally on panoramic radiograph...
Strategies of Osteosynthesis: Problems and Perspectives
Strategies of Osteosynthesis: Problems and Perspectives
Background. Urgent osteosynthesis requires number of organizational, material, technical and staff resources.
Aim of the study to determine advantages and disadvantages of existi...
Resource-efficient technology for the utilization of serpentine technogenic waste with the production of magnesium oxide
Resource-efficient technology for the utilization of serpentine technogenic waste with the production of magnesium oxide
The article discusses the possibility of using serpentine and serpentine waste from Zhitikara deposit for the production of inorganic magnesium compounds: MgSO4, Mg(OH)2 and MgO. T...
The influence of wisdom tooth impaction and occlusal support on mandibular angle and condyle fractures
The influence of wisdom tooth impaction and occlusal support on mandibular angle and condyle fractures
Abstract
This study aimed to analyze the relationship of the occlusal support together with the lower third molars to the mandibular fractures of the angle and co...
Variables Associated With Loss of Fixation of Retrograde Rami Screws in Minimally Displaced Lateral Compression Type 1 Pelvic Ring Injuries
Variables Associated With Loss of Fixation of Retrograde Rami Screws in Minimally Displaced Lateral Compression Type 1 Pelvic Ring Injuries
OBJECTIVES:
To evaluate variables associated with loss of fixation of retrograde rami screws in the treatment of stress-positive minimally displaced lateral compression...
Pullout strength of monocortical and bicortical screws in meta -physeal and diaphyseal regions of the canine humerus
Pullout strength of monocortical and bicortical screws in meta -physeal and diaphyseal regions of the canine humerus
Summary
Objective: Monocortical screws are commonly employed in locking plate fixation, but specific recommendations for their placement are lacking and use of short mono...
What is the Proper Composition of the Dialysate Magnesium and How Much Magnesium is Removed During Pre-Dilution Online Hemodiafiltration?
What is the Proper Composition of the Dialysate Magnesium and How Much Magnesium is Removed During Pre-Dilution Online Hemodiafiltration?
Aim: The aim of the study was to determine the ideal dialysate magnesium during hemodialysis, knowing that the
solution used is not satisfactory and is often associated with low se...

