Javascript must be enabled to continue!
Deciding When to Omit Repeat Transurethral Resection of Superficial Bladder Cancer: Do Photodynamic Diagnostics help?
View through CrossRef
BACKGROUND:
Repeat transurethral resection of bladder tumor is recommended when certain risk constellations are present on initial resection. Current evidence is conflicting, leading to dissenting recommendations in multinational guidelines around the world. Photodynamic diagnostics (PDD) is a tool which has been shown to increase diagnostic accuracy, but evidence is still lacking if this may permit omission of repeat resections in certain cases.
OBJECTIVE:
To evaluate whether the use of photodynamic diagnostics has an impact on resection quality and residual tumor rate, and to explore which parameters may have an impact on the necessity of repeat transurethral resections.
METHODS:
We retrospectively evaluated 373 patients in the timeframe of ten years, in whom a repeat transurethral resection of bladder tumor has been performed following initial resection at our department. About half of those resections were performed using photodynamic diagnostics.
RESULTS:
When PDD was used, more tumor mass was revealed and resected, but the shown trend toward a lower residual tumor rate was non-significant. Muscularis was shown more often on PDD resections. While being a rare occurrence, upstaging on repeat resection happened significantly less often after initial PDD use. Furthermore, tumor size and multifocality significantly influenced residual tumor rate in Ta high-grade stage.
CONCLUSIONS:
PDD use may lead to a more accurate initial staging but this may not have an impact on short-term residual tumor rate. Tumor size and multifocality should be granted more weight in the decision-making process as when to perform a repeat resection.
Title: Deciding When to Omit Repeat Transurethral Resection of Superficial Bladder Cancer: Do Photodynamic Diagnostics help?
Description:
BACKGROUND:
Repeat transurethral resection of bladder tumor is recommended when certain risk constellations are present on initial resection.
Current evidence is conflicting, leading to dissenting recommendations in multinational guidelines around the world.
Photodynamic diagnostics (PDD) is a tool which has been shown to increase diagnostic accuracy, but evidence is still lacking if this may permit omission of repeat resections in certain cases.
OBJECTIVE:
To evaluate whether the use of photodynamic diagnostics has an impact on resection quality and residual tumor rate, and to explore which parameters may have an impact on the necessity of repeat transurethral resections.
METHODS:
We retrospectively evaluated 373 patients in the timeframe of ten years, in whom a repeat transurethral resection of bladder tumor has been performed following initial resection at our department.
About half of those resections were performed using photodynamic diagnostics.
RESULTS:
When PDD was used, more tumor mass was revealed and resected, but the shown trend toward a lower residual tumor rate was non-significant.
Muscularis was shown more often on PDD resections.
While being a rare occurrence, upstaging on repeat resection happened significantly less often after initial PDD use.
Furthermore, tumor size and multifocality significantly influenced residual tumor rate in Ta high-grade stage.
CONCLUSIONS:
PDD use may lead to a more accurate initial staging but this may not have an impact on short-term residual tumor rate.
Tumor size and multifocality should be granted more weight in the decision-making process as when to perform a repeat resection.
Related Results
Transurethral incision of the bladder neck in recurrent bladder neck stenosis
Transurethral incision of the bladder neck in recurrent bladder neck stenosis
BACKGROUND: Transurethral incision of the bladder neck is one of the main methods of correction of bladder neck stenosis that occurred after treatment of patients with benign prost...
RECURRENCE RATE AFTER REPEAT TRANSURETHRAL RESECTION AMONG PATIENTS WITH NEWLY DIAGNOSED T1 BLADDER CANCER
RECURRENCE RATE AFTER REPEAT TRANSURETHRAL RESECTION AMONG PATIENTS WITH NEWLY DIAGNOSED T1 BLADDER CANCER
Background: Transurethral resection of the bladder tumor (TURBT) is the cornerstone of diagnosis and TURBT
followed by selective adjuvant intravesical chemotherapy or immunotherapy...
<b>PATTERN AND BURDEN OF COMPLICATIONS OF INTRAVESICAL BACILLUS CALMETTE-GUERIN AFTER TRANSURETHRAL RESECTION OF BLADDER TUMOR IN NON-MUSCLE INVASIVE BLADDER TUMOR</b>
<b>PATTERN AND BURDEN OF COMPLICATIONS OF INTRAVESICAL BACILLUS CALMETTE-GUERIN AFTER TRANSURETHRAL RESECTION OF BLADDER TUMOR IN NON-MUSCLE INVASIVE BLADDER TUMOR</b>
Objective: To determine pattern and burden of complications of Intravesical Bacillus Calmette-Guerin after transurethral resection of bladder tumor in non-muscle invasive bladder t...
One-stage laparoscopy combined with resectoscope in the treatment of huge bladder diverticulum, multiple stones in diverticulum, multiple stones in bladder and benign prostatic hyperplasia: A case report
One-stage laparoscopy combined with resectoscope in the treatment of huge bladder diverticulum, multiple stones in diverticulum, multiple stones in bladder and benign prostatic hyperplasia: A case report
BackgroundBladder diverticulum is due to the abnormal arrangement of congenital bladder wall muscle fibers, weak limitations, combined with lower urinary tract obstruction, increas...
Comparison of holmium laser, bipolar and conventional monopolar transurethral resection of bladder tumour in primary non-muscle invasive bladder cancer
Comparison of holmium laser, bipolar and conventional monopolar transurethral resection of bladder tumour in primary non-muscle invasive bladder cancer
Objective: To compare the efficiency and safety profile of conventional monopolar, bipolar plasmakinetic and holmium laser techniques for transurethral resection of bladder tumour....
Purines modulate urinary bladder arteriolar tone
Purines modulate urinary bladder arteriolar tone
Bladder dysfunction affects millions of people, but few effective treatments are available. In humans, changes in bladder function correlate to changes in blood flow. In rodent mod...
Construct validity of UroSim® simulator for learning transurethral resection of bladder tumor
Construct validity of UroSim® simulator for learning transurethral resection of bladder tumor
Objective: There is an increasing trend to incorporate Simulator-based training in urology residency programs. The study was designed to determine the construct validity of UroSim®...
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...

