Thallium SPECT-Based Stereotactic Targeting for Brain Tumor Biopsies
View through CrossRef
MR or CT images acquired under stereotactic conditions are often used to plan and guide brain tumor biopsies. The objective of this study was to design and test a methodology to increase target selection reliability by acquiring stereotactic <sup>201</sup>Tl-SPECT data and by integrating them into the surgical planning. The three-headed Philips gamma camera system (Prism 3000) was adapted to stereotactic acquisitions (patient pallet, headholder). A software was developed for the stereotactic target determination based on SPECT images (pixel with the highest metabolic activity inside the tumor). The whole system accuracy was tested with the Elekta phantom adapted to SPECT imaging. The methodology was applied to one brain tumor biopsy. Comparison of the specific phantom coordinates evaluated in SPECT with the theoretical ones did not reveal any significant difference. In this way, our methodology including our homemade software (identification of the stereotactic frame, determination of the pixel with highest metabolic activity within the tumor in the stereotactic coordinate system) was validated. No significant geometric deformations were detected. Clinical feasibility was confirmed in 1 patient with a brain glioma. This study illustrates the feasibility and the accuracy of SPECT acquisitions with the stereotactic Leksell G-frame. The clinical relevance of this methodology is under evaluation. This definition of the target, based on the point with the highest metabolic activity within the tumor, might lead to improved diagnosis in biopsies and patient management. Furthermore, it might prepare the future for therapy aimed at delivering a therapeutic agent within a tumor.
Title: Thallium SPECT-Based Stereotactic Targeting for Brain Tumor Biopsies
Description:
MR or CT images acquired under stereotactic conditions are often used to plan and guide brain tumor biopsies.
The objective of this study was to design and test a methodology to increase target selection reliability by acquiring stereotactic <sup>201</sup>Tl-SPECT data and by integrating them into the surgical planning.
The three-headed Philips gamma camera system (Prism 3000) was adapted to stereotactic acquisitions (patient pallet, headholder).
A software was developed for the stereotactic target determination based on SPECT images (pixel with the highest metabolic activity inside the tumor).
The whole system accuracy was tested with the Elekta phantom adapted to SPECT imaging.
The methodology was applied to one brain tumor biopsy.
Comparison of the specific phantom coordinates evaluated in SPECT with the theoretical ones did not reveal any significant difference.
In this way, our methodology including our homemade software (identification of the stereotactic frame, determination of the pixel with highest metabolic activity within the tumor in the stereotactic coordinate system) was validated.
No significant geometric deformations were detected.
Clinical feasibility was confirmed in 1 patient with a brain glioma.
This study illustrates the feasibility and the accuracy of SPECT acquisitions with the stereotactic Leksell G-frame.
The clinical relevance of this methodology is under evaluation.
This definition of the target, based on the point with the highest metabolic activity within the tumor, might lead to improved diagnosis in biopsies and patient management.
Furthermore, it might prepare the future for therapy aimed at delivering a therapeutic agent within a tumor.
Related Results
Absolute quantification in brain SPECT imaging
Absolute quantification in brain SPECT imaging
Certes malalties neurològiques estan associades amb problemes en els sistemes de neurotransmissió. Una aproximació a l'estudi d'aquests sistemes és la tomografia d'emissió SPECT (S...
Complex Collision Tumors: A Systematic Review
Complex Collision Tumors: A Systematic Review
Abstract
Introduction: A collision tumor consists of two distinct neoplastic components located within the same organ, separated by stromal tissue, without histological intermixing...
Indeterminate solitary vertebral lesions on planar scintigraphy
Indeterminate solitary vertebral lesions on planar scintigraphy
Summary
Objective: This study aims to evaluate the added value of hybrid SPECT-CT in differential diagnosis of indeterminate solitary vertebral lesion (SVL) on planar sci...
[RETRACTED] Gro-X Brain Reviews - Is Gro-X Brain A Scam? v1
[RETRACTED] Gro-X Brain Reviews - Is Gro-X Brain A Scam? v1
[RETRACTED]➢Item Name - Gro-X Brain➢ Creation - Natural Organic Compound➢ Incidental Effects - NA➢ Accessibility - Online➢ Rating - ⭐⭐⭐⭐⭐➢ Click Here To Visit - Official Website - ...
Radiation Dose Reduction Strategy for SPECT/CT Bone Scan
Radiation Dose Reduction Strategy for SPECT/CT Bone Scan
Abstract
Purpose: The aim of this study is to introduce the optimization method of CT parameters to reduce patient radiation exposure in bone SPECT/CT while maintaining ima...
Are Cervical Ribs Indicators of Childhood Cancer? A Narrative Review
Are Cervical Ribs Indicators of Childhood Cancer? A Narrative Review
Abstract
A cervical rib (CR), also known as a supernumerary or extra rib, is an additional rib that forms above the first rib, resulting from the overgrowth of the transverse proce...
The Clinical Outcome of Hypofractionated Stereotactic Radiotherapy With CyberKnife Robotic Radiosurgery for Perioptic Pituitary Adenoma
The Clinical Outcome of Hypofractionated Stereotactic Radiotherapy With CyberKnife Robotic Radiosurgery for Perioptic Pituitary Adenoma
Stereotactic radiation technique including single fraction radiosurgery and conventional fractionated stereotactic radiotherapy is widely reported as an effective treatment of pitu...
Stereotactic breast biopsies: Radiological-pathological concordance in a South African referral unit
Stereotactic breast biopsies: Radiological-pathological concordance in a South African referral unit
Background: Stereotactic breast biopsies have become the gold standard for tissue diagnosis in non-palpable, sonographically occult breast abnormalities seen on mammogram. Only lim...