Activation Time Determination by High‐Resolution Electrograms. Introduction: To identify the optimal criteria for activation time (AT) determination of bipolar electrograms from normal hearts, a high‐resolution cross electrode array comprising 128 unipolar electrodes of 500‐μm spacing was used to record extracellular potentials from the left ventricular epicardium of 12 dog hearts. Methods and Results: Recordings were made during broad wavefront propagation (B wave) local elliptical wavefront propagation (E wave). Characteristics of 863 bipolar electrograms (1‐mm spacing) were constructed from unipolar data standardized for differences in polarity, then classified morphologically. Features for bipolar AT determination were compared to the time of the negative peak of the firrst temporal derivative of a unipolar electrogram situated mid‐way between the bipoles. During B wave, three distinct morphologies were observed: unipbasic (61%), biphasic (23%), and triphasic (16%). Peak voltage of uniphasic and triphasic signals was the best predictor of AT (error: 0.6 ± 0.6 msec and 0.6 ± 0.8 msec, respectively). During E wave, parallel orientation of the bipoles with respect to the direction of impulse propagation wavefront resulted in uniphasic signals (> 99%), while for perpendicular orientation of the bipoles, electrogram morphology was variable. For parallel orientation of the bipoles, peak negative voltage was the best predictor of AT for both longitudinal and transverse propagation, while for perpendicular bipole orientation, peak negative voltage was a less reliable predictor for propagation along both fiber axes. Increasing interpolar distance resulted in a degradation in AT accuracy for B wave (from 0.6 ± 0.6 msec at 1 mm to 1.1 ± 1.2 msec at 7 mm) and for E wave (from 0.4 ± 0.3 msec at 1 mm to 3.1 ± 2.9 msec at 7 mm). Conclusions: (1) The accuracy of bipolar electrograms is sensitive to wavefront direction, bipole orientation, and interpolar distance; (2) peak negative voltage of uniphasic and triphasic signals is a reliable predictor of AT, but only for B wave; (3) a maximum interpolar distance of 2 mm and bipole orientation parallel to the direction of the impulse wavefront are minimally required for accurate determination of AT during impulse propagation initiated near the recording electrodes; and (4) for impulses initiated near the recording site in normal tissue, a bipbasic or triphasic morphology almost certainly indicates that the bipolar electrode is oriented perpendicular to the wavefront direction, irrespective of fiber orientation.
Title: Activation Time Determination by High‐Resolution Unipolar and Bipolar Extracellular Electrograms in the Canine Heart
Description:
Activation Time Determination by High‐Resolution Electrograms.
Introduction: To identify the optimal criteria for activation time (AT) determination of bipolar electrograms from normal hearts, a high‐resolution cross electrode array comprising 128 unipolar electrodes of 500‐μm spacing was used to record extracellular potentials from the left ventricular epicardium of 12 dog hearts.
Methods and Results: Recordings were made during broad wavefront propagation (B wave) local elliptical wavefront propagation (E wave).
Characteristics of 863 bipolar electrograms (1‐mm spacing) were constructed from unipolar data standardized for differences in polarity, then classified morphologically.
Features for bipolar AT determination were compared to the time of the negative peak of the firrst temporal derivative of a unipolar electrogram situated mid‐way between the bipoles.
During B wave, three distinct morphologies were observed: unipbasic (61%), biphasic (23%), and triphasic (16%).
Peak voltage of uniphasic and triphasic signals was the best predictor of AT (error: 0.
6 ± 0.
6 msec and 0.
6 ± 0.
8 msec, respectively).
During E wave, parallel orientation of the bipoles with respect to the direction of impulse propagation wavefront resulted in uniphasic signals (> 99%), while for perpendicular orientation of the bipoles, electrogram morphology was variable.
For parallel orientation of the bipoles, peak negative voltage was the best predictor of AT for both longitudinal and transverse propagation, while for perpendicular bipole orientation, peak negative voltage was a less reliable predictor for propagation along both fiber axes.
Increasing interpolar distance resulted in a degradation in AT accuracy for B wave (from 0.
6 ± 0.
6 msec at 1 mm to 1.
1 ± 1.
2 msec at 7 mm) and for E wave (from 0.
4 ± 0.
3 msec at 1 mm to 3.
1 ± 2.
9 msec at 7 mm).
Conclusions: (1) The accuracy of bipolar electrograms is sensitive to wavefront direction, bipole orientation, and interpolar distance; (2) peak negative voltage of uniphasic and triphasic signals is a reliable predictor of AT, but only for B wave; (3) a maximum interpolar distance of 2 mm and bipole orientation parallel to the direction of the impulse wavefront are minimally required for accurate determination of AT during impulse propagation initiated near the recording electrodes; and (4) for impulses initiated near the recording site in normal tissue, a bipbasic or triphasic morphology almost certainly indicates that the bipolar electrode is oriented perpendicular to the wavefront direction, irrespective of fiber orientation.

Related Results

Relation of High‐Pass Filtered Unipolar Electrograms to Bipolar Electrograms during Ventricular Mapping
Relation of High‐Pass Filtered Unipolar Electrograms to Bipolar Electrograms during Ventricular Mapping
Background : A filtered bipolar electrogram (EG) amplitude <1.5 mV is a robust indicator of relatively dense scar, but is influenced by the wavefront direction. Unipol...
A comparison of unipolar and bipolar electrograms for cardiac pacemaker sensing.
A comparison of unipolar and bipolar electrograms for cardiac pacemaker sensing.
Simultaneous unipolar and bipolar electrograms were recorded and compared from 49 pacemaker patients with bipolar endocardial electrodes. Average bipolar depolarization signal volt...
The effects of aging on atrial endocardial electrograms in patients with paroxysmal atrial fibrillation
The effects of aging on atrial endocardial electrograms in patients with paroxysmal atrial fibrillation
AbstractBackground: The prevalence of atrial fibrillation (AF) has been reported to increase with advancing age. Histologic studies in AF have demonstrated that the percentage of f...
Bipolar disorders and suicidal behaviour
Bipolar disorders and suicidal behaviour
Rihmer Z, Kiss K. Bipolar disorders and suicidal behaviour. 
Bipolar Disord 2002: 4(Suppl. 1): 21–25. © Blackwell Munksgaard, 2002Major depressive disorder is the leading cause of ...
Epicardial Mapping: How to Measure Local Activation?
Epicardial Mapping: How to Measure Local Activation?
Epicardial ventricular mapping was performed in 5 dogs during sinus rhythm with a sock array containing 41 electrodes. Maps were generated with a computer‐assisted mapping system u...
Analisis Penyalahgunaan Zat sebagai Faktor Risiko Kejadian Gangguan Bipolar pada Orang Dewasa
Analisis Penyalahgunaan Zat sebagai Faktor Risiko Kejadian Gangguan Bipolar pada Orang Dewasa
Abstract. Bipolar disorder is an emotional disorder with recurrent episodes of mood swings and depression, followed by changes in activity or energy and associated with characteris...
Abstract 1772: A naturally occurring canine model of peripheral T-cell lymphoma, not otherwise specified
Abstract 1772: A naturally occurring canine model of peripheral T-cell lymphoma, not otherwise specified
Abstract Despite being the most common subtype of human peripheral T-cell lymphoma (PTCL), PTCL-not otherwise specified (PTCL-NOS) remains a poorly understood diagno...

Back to Top