Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

A highly sensitive spectrofluorimetric method for the determination of bilastine in human plasma: Application of content uniformity testing

View through CrossRef
AbstractBilastine, a new second generation antihistaminic drug, has been widely used for relieving symptoms of allergic rhinitis and urticaria without a sedative effect. A simple, cost‐effective, and highly sensitive fluorimetric method was developed for the estimation of bilastine in human plasma, in addition to its pure state and tablets. The suggested method depended on binary complex formation of eosin with bilastine in a buffered medium at pH 4.2. The formed complex resulted in quantitative quenching of eosin emission at 538 nm after excitation at 335 nm. This method demonstrates a broad range of linearity, spanning from 200 to 1000 ng/mL, and exhibits exceptional sensitivity, with a limit of detection and quantitation of 30.85 and 93.48 ng/mL, respectively. In addition, this spectrofluorimetric method may be employed to determine the amount of bilastine in human plasma and tablets with satisfactory accuracy and excellent precision. Furthermore, the content uniformity of bilastine in commercially available tablets was successfully tested by this approach. Compared with the reference method, there were no significant variations in terms of precision or accuracy. In conclusion, the proposed protocol is highly recommended to quantitatively estimate bilastine in different quality control settings.
Title: A highly sensitive spectrofluorimetric method for the determination of bilastine in human plasma: Application of content uniformity testing
Description:
AbstractBilastine, a new second generation antihistaminic drug, has been widely used for relieving symptoms of allergic rhinitis and urticaria without a sedative effect.
A simple, cost‐effective, and highly sensitive fluorimetric method was developed for the estimation of bilastine in human plasma, in addition to its pure state and tablets.
The suggested method depended on binary complex formation of eosin with bilastine in a buffered medium at pH 4.
2.
The formed complex resulted in quantitative quenching of eosin emission at 538 nm after excitation at 335 nm.
This method demonstrates a broad range of linearity, spanning from 200 to 1000 ng/mL, and exhibits exceptional sensitivity, with a limit of detection and quantitation of 30.
85 and 93.
48 ng/mL, respectively.
In addition, this spectrofluorimetric method may be employed to determine the amount of bilastine in human plasma and tablets with satisfactory accuracy and excellent precision.
Furthermore, the content uniformity of bilastine in commercially available tablets was successfully tested by this approach.
Compared with the reference method, there were no significant variations in terms of precision or accuracy.
In conclusion, the proposed protocol is highly recommended to quantitatively estimate bilastine in different quality control settings.

Related Results

A Validated Stability Indicating HPTLC Method for Bilastine and Montelukast in Pharmaceutical Dosage Form
A Validated Stability Indicating HPTLC Method for Bilastine and Montelukast in Pharmaceutical Dosage Form
An accurate and precise and robust method has been described for Stability Indicating HPTLC method for development and validation for Bilastine and Montelukast in pharmaceutical do...
Pharmacological profile of antihistamines: focus on unwanted drug interactions
Pharmacological profile of antihistamines: focus on unwanted drug interactions
Differences between individual antihistamines are determined by such pharmacokinetic properties as the rate and completeness of absorption, half-life, the participation of hepatic ...
Photodegradation kinetics of Bilastine in tablets
Photodegradation kinetics of Bilastine in tablets
Photodegradation is the process by which a chemical substance is broken down through exposure to light, typically ultraviolet (UV) radiation. This process is significant in environ...
Efficacy of Bilastine in the Management of Urticaria- A Retrospective Study
Efficacy of Bilastine in the Management of Urticaria- A Retrospective Study
Background: Urticaria or hives is a common skin condition with a lifetime prevalence of 7.8–22.3%, a point prevalence of 0.5- 1.0%. This study focuses to determine the efficacy of ...
Magnetohydrodynamics enhanced radio blackout mitigation system for spacecraft during planetary entries
Magnetohydrodynamics enhanced radio blackout mitigation system for spacecraft during planetary entries
(English) Spacecraft entering planetary atmospheres are enveloped by a plasma layer with high levels of ionization, caused by the extreme temperatures in the shock layer. The charg...
Development and Validation of RP-HPLC Method for the Simultaneous Estimation of Bilastine and Montelukast in Tablet Dosage Form
Development and Validation of RP-HPLC Method for the Simultaneous Estimation of Bilastine and Montelukast in Tablet Dosage Form
Place of Study: Department of Pharmacy, University College of Technology, Osmania University, Hyderabad, Telangana. Aim: The present study is describing about the development of a...
Evolution and effectiveness of HPLC technique for rapid estimation of an antiallergenic agent bilastine
Evolution and effectiveness of HPLC technique for rapid estimation of an antiallergenic agent bilastine
A new, simple, accurate and specific RP-HPLC stability indicating method for determination of bilastine has been developed and validated. The proposed method has been administrated...

Back to Top