Javascript must be enabled to continue!
Minimizing Pedicle Screw Pullout Risks
View through CrossRef
Study Design:
Detailed biomechanical analysis of the anchorage performance provided by different pedicle screw designs and placement strategies under pullout loading.
Objective:
To biomechanically characterize the specific effects of surgeon-specific pedicle screw design parameters on anchorage performance using a finite element model.
Summary of Background Data:
Pedicle screw fixation is commonly used in the treatment of spinal pathologies. However, there is little consensus on the selection of an optimal screw type, size, and insertion trajectory depending on vertebra dimension and shape.
Methods:
Different screw diameters and lengths, threads, and insertion trajectories were computationally tested using a design of experiment approach. A detailed finite element model of an L3 vertebra was created including elastoplastic bone properties and contact interactions with the screws. Loads and boundary conditions were applied to the screws to simulate axial pullout tests. Force-displacement responses and internal stresses were analyzed to determine the specific effects of each parameter.
Results:
The design of experiment analysis revealed significant effects (P<0.01) for all tested principal parameters along with the interactions between diameter and trajectory. Screw diameter had the greatest impact on anchorage performance. The best insertion trajectory to resist pullout involved placing the screw threads closer to the pedicle walls using the straightforward insertion technique, which showed the importance of the cortical layer grip. The simulated cylindrical single-lead thread screws presented better biomechanical anchorage than the conical dual-lead thread screws in axial loading conditions.
Conclusions:
The model made it possible to quantitatively measure the effects of both screw design characteristics and surgical choices, enabling to recommend strategies to improve single pedicle screw performance under axial loading.
Ovid Technologies (Wolters Kluwer Health)
Title: Minimizing Pedicle Screw Pullout Risks
Description:
Study Design:
Detailed biomechanical analysis of the anchorage performance provided by different pedicle screw designs and placement strategies under pullout loading.
Objective:
To biomechanically characterize the specific effects of surgeon-specific pedicle screw design parameters on anchorage performance using a finite element model.
Summary of Background Data:
Pedicle screw fixation is commonly used in the treatment of spinal pathologies.
However, there is little consensus on the selection of an optimal screw type, size, and insertion trajectory depending on vertebra dimension and shape.
Methods:
Different screw diameters and lengths, threads, and insertion trajectories were computationally tested using a design of experiment approach.
A detailed finite element model of an L3 vertebra was created including elastoplastic bone properties and contact interactions with the screws.
Loads and boundary conditions were applied to the screws to simulate axial pullout tests.
Force-displacement responses and internal stresses were analyzed to determine the specific effects of each parameter.
Results:
The design of experiment analysis revealed significant effects (P<0.
01) for all tested principal parameters along with the interactions between diameter and trajectory.
Screw diameter had the greatest impact on anchorage performance.
The best insertion trajectory to resist pullout involved placing the screw threads closer to the pedicle walls using the straightforward insertion technique, which showed the importance of the cortical layer grip.
The simulated cylindrical single-lead thread screws presented better biomechanical anchorage than the conical dual-lead thread screws in axial loading conditions.
Conclusions:
The model made it possible to quantitatively measure the effects of both screw design characteristics and surgical choices, enabling to recommend strategies to improve single pedicle screw performance under axial loading.
Related Results
The Evaluation of a Novel Three-Dimensional Printed Expandable Pedicle Screw Sleeve Insert
The Evaluation of a Novel Three-Dimensional Printed Expandable Pedicle Screw Sleeve Insert
When used in combination with decompression, spinal fusion is a successful procedure for treating patients with spinal stenosis and degenerative spondylolisthesis. While a number o...
Stiffness Comparisons of SOP Interlocking Plate Configurations in 3D Printed Canine Lumbosacral Vertebrae
Stiffness Comparisons of SOP Interlocking Plate Configurations in 3D Printed Canine Lumbosacral Vertebrae
There are no published biomechanical studies evaluating the effect of stabilization techniques on the stability of the 3D printed models of the canine lumbosacral junction. The p...
Experimental study on the pullout characteristics of toothed warp knitted geogrid in different sand fillers
Experimental study on the pullout characteristics of toothed warp knitted geogrid in different sand fillers
In order to investigate the pullout characteristics of a toothed geogrid, a commercialized warp-knitted geogrid was combined with rigid angle aluminum to form a qualified toothed g...
Influence of Different Fixed System in Osteoporotic Lumbar Vertebrae in Fusion:A 3D Finite Element Analysis
Influence of Different Fixed System in Osteoporotic Lumbar Vertebrae in Fusion:A 3D Finite Element Analysis
Abstract
Background:Posterior lumbar interbody fusion(PLIF) is the most common surgical method for lumbar fusion surgery, and pedicle screws(PS)can provide effective fixati...
Intraoperative triggered electromyographic monitoring of pedicle screw efficiently reduces the lumbar pedicle breach and re-operative rate-a retrospective analysis based on postoperative computed tomography scan
Intraoperative triggered electromyographic monitoring of pedicle screw efficiently reduces the lumbar pedicle breach and re-operative rate-a retrospective analysis based on postoperative computed tomography scan
Abstract
Background
To investigate whether intraoperative triggered electromyographic (T-EMG) monitoring could effectively reduce the breach rate of...
Biomechanical characterization of bilateral pedicle screw internal fixation combinations on lumbar vertebrae
Biomechanical characterization of bilateral pedicle screw internal fixation combinations on lumbar vertebrae
Purpose
Pedicle screw fixation has been considered a suitable surgical intervention for addressing a diverse range of indications involving the lumbar spinal segments, but the...
Biomechanical analysis of pedicle screw placement: a feasibility study
Biomechanical analysis of pedicle screw placement: a feasibility study
In spinal instrumentation surgery, the optimal placement of pedicle screws that takes into account the cortical/cancellous bone quality, geometry and property distribution, and scr...
Plasticating Single-Screw Extrusion
Plasticating Single-Screw Extrusion
There are two types of extruder: (1) single-screw extruders and (2) twin-screw extruders. The single-screw extruder is one of the most important pieces of equipment in the processi...