Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Can Titanium elastic nails deliver a knockout punch against precontoured locking plates in handling displaced middle third clavicle fractures?

View through CrossRef
Background: Plating is the gold standard for displaced middle third clavicle fractures, which holds true at least for comminuted fractures with a fair share of complications. For displaced fractures without comminution, intramedullary titanium elastic nailing system is an emerging option which claims similar success rates with fewer complications. There is a deficit in data pertaining to prospective trials supporting such claims which has propelled us to carry out this study. This study aims to compare the functional outcome and complication rates between precontoured locking plates and titanium elastic nails for displaced clavicle fractures. Materials and Methods: A prospective cohort study carried out on 56 patients with displaced clavicle fractures without comminution treated either by nailing (with open reduction through minimal incision at fracture site) or plating, and the results pertaining to their functional outcome and complication rates were compared. Results: Nottingham clavicle score and Constant Murley score were calculated at 6, 12, and 24 months along with comparison of complication rates. Conclusion: The functional outcome scores recorded significant differences at 6- and 12-month periods between the groups, which minimized at 24 months. Complication rates were significantly different between the groups. These results of functional outcome and complication rates point toward titanium nailing as an attractive alternative to plating for a comminuted displaced middle third clavicle fractures.
Title: Can Titanium elastic nails deliver a knockout punch against precontoured locking plates in handling displaced middle third clavicle fractures?
Description:
Background: Plating is the gold standard for displaced middle third clavicle fractures, which holds true at least for comminuted fractures with a fair share of complications.
For displaced fractures without comminution, intramedullary titanium elastic nailing system is an emerging option which claims similar success rates with fewer complications.
There is a deficit in data pertaining to prospective trials supporting such claims which has propelled us to carry out this study.
This study aims to compare the functional outcome and complication rates between precontoured locking plates and titanium elastic nails for displaced clavicle fractures.
Materials and Methods: A prospective cohort study carried out on 56 patients with displaced clavicle fractures without comminution treated either by nailing (with open reduction through minimal incision at fracture site) or plating, and the results pertaining to their functional outcome and complication rates were compared.
Results: Nottingham clavicle score and Constant Murley score were calculated at 6, 12, and 24 months along with comparison of complication rates.
Conclusion: The functional outcome scores recorded significant differences at 6- and 12-month periods between the groups, which minimized at 24 months.
Complication rates were significantly different between the groups.
These results of functional outcome and complication rates point toward titanium nailing as an attractive alternative to plating for a comminuted displaced middle third clavicle fractures.

Related Results

DIAPHYSEAL FRACTURES OF THE CLAVICLE
DIAPHYSEAL FRACTURES OF THE CLAVICLE
Introduction: clavicle fractures are common, especially in people under 25 years of age involved in sports, falls from heights or traffic accidents. Traditionally they were treated...
Surgical Management of Clavicle Fracture with Precontoured Locking Plate
Surgical Management of Clavicle Fracture with Precontoured Locking Plate
INTRODUCTION Traditionally, displaced midshaft clavicle fractures have been treated by nonoperative methods but had high rates of malunion and prolong pain. Therefore, fixation wit...
Radiological and functional outcome of conservatively managed middle one third clavicle fractures
Radiological and functional outcome of conservatively managed middle one third clavicle fractures
Background: We aim to assess radiological and functional outcome of conservatively managed middle one third clavicle fractures in Indian population. Clavicle fractures represent 2%...
Pathogenic Organisms Associated with Artificial Fingernails Worn by Healthcare Workers
Pathogenic Organisms Associated with Artificial Fingernails Worn by Healthcare Workers
Objective:To determine differences in the identity and quantity of microbial flora from healthcare workers (HCWs) wearing artificial nails compared with control HCWs with native na...
Intramedullary stabilization of dislocated clavicle fractures with a compression rod
Intramedullary stabilization of dislocated clavicle fractures with a compression rod
Despite the favorable prognosis of conservative treatment for clavicle fractures, unsatisfactory consequences reach 10–30 % cases. Surgical methods of treatment for dislocated clav...
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Treatment of midshaft clavicle fracture with anatomical contoured clavicular locking plate
Treatment of midshaft clavicle fracture with anatomical contoured clavicular locking plate
Background: Fracture clavicle is a common fracture around the shoulder joint accounting about 2.6% of all fracture and 44% in shoulder region. Mid shaft clavicle fracture accounts ...

Back to Top