Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Intramedullary stabilization of dislocated clavicle fractures with a compression rod

View through CrossRef
Despite the favorable prognosis of conservative treatment for clavicle fractures, unsatisfactory consequences reach 10–30 % cases. Surgical methods of treatment for dislocated clavicle fractures, such as osteosynthesis with a plate or an elastic titanium rod, are mostly used in practice. The disadvantage of the latter is the possible migration of the implant with perforation of the skin. The purpose was to study the effectiveness of an intramedullary rod, improved by us, for osteosynthesis of dislocated clavicle fractures type OTA 15A and OTA 15B according to the AO/ASIF classification. The essence of the improvement was the possibility of closed minimally invasive intramedullary osteosynthesis of the clavicle body, with a simplified technique of the surgical intervention itself, prevention of implant migration. The latter was achieved by the fact that one of the ends of the rod had a drill, which eliminated the need for predrilling the medullary cavity of the clavicle to insert the rod, and its opposite end had a thread onto which a nut is screwed to achieve compression between the clavicular fragments. Forty-two patients with closed dislocated clavicle fractures were under supervision in the clinic of traumatology and orthopedics of Kyiv City Clinical Hospital 6. They underwent intramedullary osteosynthesis for clavicle fractures with an improved compressing rod (closed in 28 cases, open in 14) under regional anesthesia. In dyna-mics of the postoperative period, a clinical and radiological examination was performed, the severity of the pain syndrome and the function of the upper limb were assessed according to the visual analog scale (VAS), Disability of Arm, Shoulder and Hand (DASH). As shown by the results of X-ray examinations, the average period of clavicle fracture union was 10.1 ± 1.4 weeks (range 8–12 weeks). During the observation of the patients, favorable dynamics on the VAS and DASH were noted; by the end of the study (12 months after the operation), the functional capabilities of the upper limb on the DASH corresponded to 1.54 ± 0.84 points, VAS score was 9.60 ± 2.11 points. The improved construction of the intramedullary rod for osteosynthesis of dislocated clavicle fractures of the OTA 15A and OTA 15B type can be recommended for use in practice, as it has demonstrated favorable clinical, radiological, and functional outcomes.
Title: Intramedullary stabilization of dislocated clavicle fractures with a compression rod
Description:
Despite the favorable prognosis of conservative treatment for clavicle fractures, unsatisfactory consequences reach 10–30 % cases.
Surgical methods of treatment for dislocated clavicle fractures, such as osteosynthesis with a plate or an elastic titanium rod, are mostly used in practice.
The disadvantage of the latter is the possible migration of the implant with perforation of the skin.
The purpose was to study the effectiveness of an intramedullary rod, improved by us, for osteosynthesis of dislocated clavicle fractures type OTA 15A and OTA 15B according to the AO/ASIF classification.
The essence of the improvement was the possibility of closed minimally invasive intramedullary osteosynthesis of the clavicle body, with a simplified technique of the surgical intervention itself, prevention of implant migration.
The latter was achieved by the fact that one of the ends of the rod had a drill, which eliminated the need for predrilling the medullary cavity of the clavicle to insert the rod, and its opposite end had a thread onto which a nut is screwed to achieve compression between the clavicular fragments.
Forty-two patients with closed dislocated clavicle fractures were under supervision in the clinic of traumatology and orthopedics of Kyiv City Clinical Hospital 6.
They underwent intramedullary osteosynthesis for clavicle fractures with an improved compressing rod (closed in 28 cases, open in 14) under regional anesthesia.
In dyna-mics of the postoperative period, a clinical and radiological examination was performed, the severity of the pain syndrome and the function of the upper limb were assessed according to the visual analog scale (VAS), Disability of Arm, Shoulder and Hand (DASH).
As shown by the results of X-ray examinations, the average period of clavicle fracture union was 10.
1 ± 1.
4 weeks (range 8–12 weeks).
During the observation of the patients, favorable dynamics on the VAS and DASH were noted; by the end of the study (12 months after the operation), the functional capabilities of the upper limb on the DASH corresponded to 1.
54 ± 0.
84 points, VAS score was 9.
60 ± 2.
11 points.
The improved construction of the intramedullary rod for osteosynthesis of dislocated clavicle fractures of the OTA 15A and OTA 15B type can be recommended for use in practice, as it has demonstrated favorable clinical, radiological, and functional outcomes.

Related Results

DIAPHYSEAL FRACTURES OF THE CLAVICLE
DIAPHYSEAL FRACTURES OF THE CLAVICLE
Introduction: clavicle fractures are common, especially in people under 25 years of age involved in sports, falls from heights or traffic accidents. Traditionally they were treated...
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Abstract Thoracic outlet syndrome (TOS) is a complex and often overlooked condition caused by the compression of neurovascular structures as they pass through the thoracic outlet. ...
Effects of Criterion Values on Estimation of the Radius of Drainage and Stabilization Time
Effects of Criterion Values on Estimation of the Radius of Drainage and Stabilization Time
Abstract After a well starts flowing, a larger portion of the reservoir contributes to production. At any given time, the radius of the portion of the reservoir t...
Effects of Criterion Values on Estimation of the Radius of Drainage and Stabilization Time
Effects of Criterion Values on Estimation of the Radius of Drainage and Stabilization Time
Abstract After a well starts flowing, a larger and larger portion of the reservoir contributes to production. At any given time, the radius of the portion of the ...
Radiological and functional outcome of conservatively managed middle one third clavicle fractures
Radiological and functional outcome of conservatively managed middle one third clavicle fractures
Background: We aim to assess radiological and functional outcome of conservatively managed middle one third clavicle fractures in Indian population. Clavicle fractures represent 2%...
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Stochastic Propagation of Discrete Fracture Networks
Stochastic Propagation of Discrete Fracture Networks
This reference is for an abstract only. A full paper was not submitted for this conference. Abstract Fractures are ubiquitous st...
Ribbon Rod - Improvement in Sucker Rod Technology Shows Need to Re-Evaluate Current Artificial Lift Installations
Ribbon Rod - Improvement in Sucker Rod Technology Shows Need to Re-Evaluate Current Artificial Lift Installations
Abstract This study describes ribbon rod as a continuous graphite composite material that can be currently used to partially replace a conventional sucker rod str...

Back to Top