Javascript must be enabled to continue!
Experimental Study on Flow Behavior and Heat Transfer Enhancement With Distinct Dimpled Gas Turbine Blade Internal Cooling Channel
View through CrossRef
AbstractThe study presents the investigation on heat transfer distribution along a gas turbine blade internal cooling channel. Six different cases were considered in this study, using the smooth surface channel as a baseline. Three different dimples depth-to-diameter ratios with 0.1, 0.25, and 0.50 were considered. Different combinations of partial spherical and leaf dimples were also studied with the Reynolds numbers of 6,000, 20,000, 30,000, 40,000, and 50,000. In addition to the experimental investigation, the numerical study was conducted using a large eddy simulation (LES) to validate the data. It was found that the highest depth-to-diameter ratio showed the highest heat transfer rate. However, the deepest dimpled channel shows the highest pressure drop, which affects the overall thermal performance of the cooling channel. The results showed that the leaf dimpled surface is the best cooling channel based on the highest Reynolds number's heat transfer enhancement and friction factor. However, at the lowest Reynolds number, partial spherical dimples with a 0.25 depth-to-diameter ratio showed the highest thermal performance.
Title: Experimental Study on Flow Behavior and Heat Transfer Enhancement With Distinct Dimpled Gas Turbine Blade Internal Cooling Channel
Description:
AbstractThe study presents the investigation on heat transfer distribution along a gas turbine blade internal cooling channel.
Six different cases were considered in this study, using the smooth surface channel as a baseline.
Three different dimples depth-to-diameter ratios with 0.
1, 0.
25, and 0.
50 were considered.
Different combinations of partial spherical and leaf dimples were also studied with the Reynolds numbers of 6,000, 20,000, 30,000, 40,000, and 50,000.
In addition to the experimental investigation, the numerical study was conducted using a large eddy simulation (LES) to validate the data.
It was found that the highest depth-to-diameter ratio showed the highest heat transfer rate.
However, the deepest dimpled channel shows the highest pressure drop, which affects the overall thermal performance of the cooling channel.
The results showed that the leaf dimpled surface is the best cooling channel based on the highest Reynolds number's heat transfer enhancement and friction factor.
However, at the lowest Reynolds number, partial spherical dimples with a 0.
25 depth-to-diameter ratio showed the highest thermal performance.
Related Results
Film Cooling Calculations With an Iterative Conjugate Heat Transfer Approach Using Empirical Heat Transfer Coefficient Corrections
Film Cooling Calculations With an Iterative Conjugate Heat Transfer Approach Using Empirical Heat Transfer Coefficient Corrections
An iterative conjugate heat transfer technique has been developed to predict the temperatures on film cooled surfaces such as flat plates and turbine blades. Conventional approache...
Heat Transfer and Flow Studies of Different Cooling Configurations for Gas Turbine Rotor Blade
Heat Transfer and Flow Studies of Different Cooling Configurations for Gas Turbine Rotor Blade
Military gas turbine engine operates at turbine entry temperatures (TET) of the order of 2000K. Increase in TET improves thermal efficiency and power output. The gas temperature is...
Heat Transfer Augmentation With Multiple Jet Impingement Cooling on Dimpled Surface for Gas Turbine Blades
Heat Transfer Augmentation With Multiple Jet Impingement Cooling on Dimpled Surface for Gas Turbine Blades
Abstract
Multiple jet impingement cooling plays a significant role in the leading-edge cooling of the gas turbine blade. The heat transfer enhancement with this meth...
[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED]Rhino XL Reviews, NY USA: Studies show that testosterone levels in males decrease constantly with growing age. There are also many other problems that males face due ...
Application of conjugate heat transfer and fluid network analysis to improvement design of turbine blade with integrated cooling structures
Application of conjugate heat transfer and fluid network analysis to improvement design of turbine blade with integrated cooling structures
A combination of fluid network analysis method with conjugate heat transfer are applied to the improvement design of the integrated cooling structures in a high-performance turbine...
Air-Conditioning Using Waste Heat Energy
Air-Conditioning Using Waste Heat Energy
Abstract
All oil & gas building facilities such as control room, electrical room, substation and personal accommodation etc., require a comfortable indoor condit...
Heat Transfer and Film Cooling of Blade Tips and Endwalls
Heat Transfer and Film Cooling of Blade Tips and Endwalls
This paper investigates the flow, heat transfer and film cooling effectiveness of advanced high-pressure turbine blade tips and endwall. Two blade tip configurations have been stud...
En skvatmølle i Ljørring
En skvatmølle i Ljørring
A Horizontal Mill at Ljørring, Jutland.Horizontal water-mills have been in use in Jutland since the beginning of the Christian era 2). But the one here described shows so close a c...

