Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

DESIGN AND SIMULATION OF MULTICHANNEL QCM DEVICES

View through CrossRef
QCM (Quartz Crystal Microbalance) is a widely used biosensor in multiple industries and fields including medical, food safety and environmental health. However, its advances are predominantly focused on utilizing single channel on a QCM substrate. This limits the active area on QCM limited to the single channel and wastes the potential of the surface area of the substrate. The data received from a single channel QCM also lacks certainty where there is no other sensor that can verify or do cross-checking on its data real-time. The existing quartz thickness of 168μm does produce a high resonance frequency, however the QCM device is prone to break because of its extremely thin substrate, making it hard to handle. The aim of this study is to investigate, design and simulate the most significant parameters that contribute to the performance of multichannel QCM devices. The study examines the suitable quartz thickness and electrode sensor radius for single channel QCM, then proceeds to vary the c2c distance for multichannel QCM design. The study found that 1.5mm is the optimal radius of electrode sensor for quartz thickness of 168μm single channel QCM with a resonance frequency of 6.17MHz. 4mm is the optimal c2c distance for 2-channel, 3-channel and 4-channel QCM. Future improvements on the multichannel QCM device should include introducing a sensing layer to detect certain compounds and using multiple channels on a single substrate to detect multiple compounds simultaneously.
Title: DESIGN AND SIMULATION OF MULTICHANNEL QCM DEVICES
Description:
QCM (Quartz Crystal Microbalance) is a widely used biosensor in multiple industries and fields including medical, food safety and environmental health.
However, its advances are predominantly focused on utilizing single channel on a QCM substrate.
This limits the active area on QCM limited to the single channel and wastes the potential of the surface area of the substrate.
The data received from a single channel QCM also lacks certainty where there is no other sensor that can verify or do cross-checking on its data real-time.
The existing quartz thickness of 168μm does produce a high resonance frequency, however the QCM device is prone to break because of its extremely thin substrate, making it hard to handle.
The aim of this study is to investigate, design and simulate the most significant parameters that contribute to the performance of multichannel QCM devices.
The study examines the suitable quartz thickness and electrode sensor radius for single channel QCM, then proceeds to vary the c2c distance for multichannel QCM design.
The study found that 1.
5mm is the optimal radius of electrode sensor for quartz thickness of 168μm single channel QCM with a resonance frequency of 6.
17MHz.
4mm is the optimal c2c distance for 2-channel, 3-channel and 4-channel QCM.
Future improvements on the multichannel QCM device should include introducing a sensing layer to detect certain compounds and using multiple channels on a single substrate to detect multiple compounds simultaneously.

Related Results

Shortened 'Thrombin Time' Monitoring on QCM-D: A Better Substitute of 'Gold Standard'
Shortened 'Thrombin Time' Monitoring on QCM-D: A Better Substitute of 'Gold Standard'
Thrombin is the central enzyme in the coagulation cascade. Recently, modern technologies for thrombin generation measurement have shown a multidisciplinary interest in methods and ...
Adsorption of Saliva Related Protein on Denture Materials: An X-Ray Photoelectron Spectroscopy and Quartz Crystal Microbalance Study
Adsorption of Saliva Related Protein on Denture Materials: An X-Ray Photoelectron Spectroscopy and Quartz Crystal Microbalance Study
The aim of this study was to evaluate the difference in the adsorption behavior of different types of bovine salivary proteins on the PMMA and Ti QCM sensors are fabricated by spin...
A Simultaneous Monitoring of Coagulation Time and Fibrinogen via PiCT on QCM-D
A Simultaneous Monitoring of Coagulation Time and Fibrinogen via PiCT on QCM-D
‘Prothrombinase induced Clotting Time’ (PiCT) has potential to detect all anticoagulants in clinics. In the present study, PiCT has been used as a tool for anticoagulant detection ...
QCM Biosensors for pathogen detection in water and food: review of published literature
QCM Biosensors for pathogen detection in water and food: review of published literature
Introduction:This article is the result of the review “QCM Biosensors for the Detection of Pathogens in Water and Food: A Review,’ conducted during the years 2023 and 2024 at the U...
Prothrombin Time (PT) for Human Plasma on QCM-D Platform: A Better Alternative to 'Gold Standard'
Prothrombin Time (PT) for Human Plasma on QCM-D Platform: A Better Alternative to 'Gold Standard'
Measurements of hemostasis parameters such as Prothrombin time (PT) are substantial in various clinical cases of extensive surgery, dialysis or innate hemostasis disorders. This is...
Design
Design
Conventional definitions of design rarely capture its reach into our everyday lives. The Design Council, for example, estimates that more than 2.5 million people use design-related...
SPATIO-TEMPORAL CHARACTERISTICS OF MULTICHANNEL ELCTROMYOGRAPHY
SPATIO-TEMPORAL CHARACTERISTICS OF MULTICHANNEL ELCTROMYOGRAPHY
This paper discusses the spatio-temporal properties of multichannel electromyographic (EMG) signals and investigates muscle force estimates obtained by multichannel myoprocessor. T...
aPTT: 1st Recognition for Human Whole Blood on QCM-D Platform
aPTT: 1st Recognition for Human Whole Blood on QCM-D Platform
Activated partial thromboplastin time (aPTT) assay for whole blood on quartz crystal microbalance with dissipation (QCM-D) platform has been recognized for the first time. QCM-D pl...

Back to Top