Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Bioactive and Thermally Compatible Glass Coating on Zirconia Dental Implants

View through CrossRef
The healing time of zirconia implants may be reduced by the use of bioactive glass coatings. Unfortunately, existing glasses are either bioactive like Bioglass 45S5 but thermally incompatible with the zirconia substrate, or they are thermally compatible but exhibit only a very low level of bioactivity. In this study, we hypothesized that a tailored substitution of alkaline earth metals and alkaline metals in 45S5 can lead to a glass composition that is both bioactive and thermally compatible with zirconia implants. A novel glass composition was analyzed using x-ray fluorescence spectroscopy, dilatometry, differential scanning calorimetry, and heating microscopy to investigate its chemical, physical, and thermal properties. Bioactivity was tested in vitro using simulated body fluid (SBF). Smooth and microstructured glass coatings were applied using a tailored spray technique with subsequent thermal treatment. Coating adhesion was tested on implants that were inserted in bovine ribs. The cytocompatibility of the coating was analyzed using L929 mouse fibroblasts. The coefficient of thermal expansion of the novel glass was shown to be slightly lower (11.58·10 –6 K –1 ) than that of the zirconia (11.67·10 –6 K –1 ). After storage in SBF, the glass showed reaction layers almost identical to the bioactive glass gold standard, 45S5. A process window between 800 °C and 910 °C was found to result in densely sintered and amorphous coatings. Microstructured glass coatings on zirconia implants survived a minimum insertion torque of 60 Ncm in the in vitro experiment on bovine ribs. Proliferation and cytotoxicity of the glass coatings was comparable with the controls. The novel glass composition showed a strong adhesion to the zirconia substrate and a significant bioactive behavior in the SBF in vitro experiments. Therefore, it holds great potential to significantly reduce the healing time of zirconia dental implants.
Title: Bioactive and Thermally Compatible Glass Coating on Zirconia Dental Implants
Description:
The healing time of zirconia implants may be reduced by the use of bioactive glass coatings.
Unfortunately, existing glasses are either bioactive like Bioglass 45S5 but thermally incompatible with the zirconia substrate, or they are thermally compatible but exhibit only a very low level of bioactivity.
In this study, we hypothesized that a tailored substitution of alkaline earth metals and alkaline metals in 45S5 can lead to a glass composition that is both bioactive and thermally compatible with zirconia implants.
A novel glass composition was analyzed using x-ray fluorescence spectroscopy, dilatometry, differential scanning calorimetry, and heating microscopy to investigate its chemical, physical, and thermal properties.
Bioactivity was tested in vitro using simulated body fluid (SBF).
Smooth and microstructured glass coatings were applied using a tailored spray technique with subsequent thermal treatment.
Coating adhesion was tested on implants that were inserted in bovine ribs.
The cytocompatibility of the coating was analyzed using L929 mouse fibroblasts.
The coefficient of thermal expansion of the novel glass was shown to be slightly lower (11.
58·10 –6 K –1 ) than that of the zirconia (11.
67·10 –6 K –1 ).
After storage in SBF, the glass showed reaction layers almost identical to the bioactive glass gold standard, 45S5.
A process window between 800 °C and 910 °C was found to result in densely sintered and amorphous coatings.
Microstructured glass coatings on zirconia implants survived a minimum insertion torque of 60 Ncm in the in vitro experiment on bovine ribs.
Proliferation and cytotoxicity of the glass coatings was comparable with the controls.
The novel glass composition showed a strong adhesion to the zirconia substrate and a significant bioactive behavior in the SBF in vitro experiments.
Therefore, it holds great potential to significantly reduce the healing time of zirconia dental implants.

Related Results

Awareness of Dental Personnel towards Occupational Injury- A Cross Sectional Study
Awareness of Dental Personnel towards Occupational Injury- A Cross Sectional Study
TITLE: Awareness of dental personnel towards occupational injury- a cross sectional study ABSTRACT Objective: To determine the awareness of dental personnel towards dental occup...
Unveiling the third dimension of glass
Unveiling the third dimension of glass
Glass as a material has always fascinated architects. Its inherent transparency has given us the ability to create diaphanous barriers between the interior and the exterior that al...
Surrounding Tissue Response to Surface-Treated Zirconia Implants
Surrounding Tissue Response to Surface-Treated Zirconia Implants
Yttria-stabilized tetragonal zirconia polycrystals (Y-TZP), which are partially stabilized zirconia, have been used for fabricating dental implants. This study investigated the sof...
Guest Editorial
Guest Editorial
Dental caries is one of the major health problems in Indonesia. Data from Indonesian Basic Health Research in 2013, 2015 and 2018 showed a consistent increase in the prevalence of ...
Clinical outcomes of zirconia implants: a systematic review and meta-analysis
Clinical outcomes of zirconia implants: a systematic review and meta-analysis
Abstract Purpose To assess the clinical outcomes of zirconia dental implants based on an updated systematic literature review. ...
Comparative Clinical Study of Conventional Dental Implants and Mini Dental Implants for Mandibular Overdentures: A Randomized Clinical Trial
Comparative Clinical Study of Conventional Dental Implants and Mini Dental Implants for Mandibular Overdentures: A Randomized Clinical Trial
AbstractBackgroundDental implant‐retained overdentures have been chosen as the treatment of choice for complete mandibular removable dentures. Dental implants, such as mini dental ...
Coating Processes of Pharmaceutical Applicability: A Glimpse
Coating Processes of Pharmaceutical Applicability: A Glimpse
Presentation of manuscript is aiming to furnish glimpse on coating processes. Coating is process of snugly covering substrate surface with coating materials (CoM). In due course co...
Management of Oblique Root Fracture Using Mineral Trioxide Aggregate: A Case Report
Management of Oblique Root Fracture Using Mineral Trioxide Aggregate: A Case Report
Root fractures are relatively uncommon compared to other types of dental traumas. It is sometimes extremely difficult for practitioners to decide what should be done and which appr...

Back to Top