Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Surrounding Tissue Response to Surface-Treated Zirconia Implants

View through CrossRef
Yttria-stabilized tetragonal zirconia polycrystals (Y-TZP), which are partially stabilized zirconia, have been used for fabricating dental implants. This study investigated the soft tissue attachment, the collagen fiber orientation to zirconia at different surface conditions, and the bone response using implantation experiments in animals. The zirconia implant surfaces were treated with ultraviolet irradiation (UV), a combination of large-grit sandblasting and hydrofluoric acid etching (blastedHF), and a combination of blastedHF and UV (blastedHF+UV). The surface treated with blastedHF and blastedHF+UV appeared rough and hydrophilic. The surface treated with blastedHF+UV appeared to be superhydrophilic. Subsequently, tapered cylindrical zirconia implants were placed in the alveolar sockets of the maxillary molars of rats. The bone-to-implant contact ratio of blastedHF and blastedHF+UV implants was significantly higher than that of the non-treated controls and UV-treated implants. The four different surface-treated zirconia implants demonstrated tight soft tissue attachments. Perpendicularly oriented collagen fibers towards zirconia implants were more prominent in blastedHF and blastedHF+UV implants compared to the controls and UV-treated implants. The area of the soft tissue attachment was the greatest with the perpendicularly oriented collagen fibers of blastedHF+UV-treated implants. In conclusion, blastedHF+UV treatment could be beneficial for ensuring greater soft-tissue attachment for zirconia implants.
Title: Surrounding Tissue Response to Surface-Treated Zirconia Implants
Description:
Yttria-stabilized tetragonal zirconia polycrystals (Y-TZP), which are partially stabilized zirconia, have been used for fabricating dental implants.
This study investigated the soft tissue attachment, the collagen fiber orientation to zirconia at different surface conditions, and the bone response using implantation experiments in animals.
The zirconia implant surfaces were treated with ultraviolet irradiation (UV), a combination of large-grit sandblasting and hydrofluoric acid etching (blastedHF), and a combination of blastedHF and UV (blastedHF+UV).
The surface treated with blastedHF and blastedHF+UV appeared rough and hydrophilic.
The surface treated with blastedHF+UV appeared to be superhydrophilic.
Subsequently, tapered cylindrical zirconia implants were placed in the alveolar sockets of the maxillary molars of rats.
The bone-to-implant contact ratio of blastedHF and blastedHF+UV implants was significantly higher than that of the non-treated controls and UV-treated implants.
The four different surface-treated zirconia implants demonstrated tight soft tissue attachments.
Perpendicularly oriented collagen fibers towards zirconia implants were more prominent in blastedHF and blastedHF+UV implants compared to the controls and UV-treated implants.
The area of the soft tissue attachment was the greatest with the perpendicularly oriented collagen fibers of blastedHF+UV-treated implants.
In conclusion, blastedHF+UV treatment could be beneficial for ensuring greater soft-tissue attachment for zirconia implants.

Related Results

Surface modification of zirconia-based bioceramics for orthopedic and dental applications
Surface modification of zirconia-based bioceramics for orthopedic and dental applications
Debido a sus excelentes propiedades mecánicas y una excelente biocompatibilidad, el uso de las cerámicas de base de circona en aplicaciones dentales y ortopédicas ha crecido rápida...
Clinical outcomes of zirconia implants: a systematic review and meta-analysis
Clinical outcomes of zirconia implants: a systematic review and meta-analysis
Abstract Purpose To assess the clinical outcomes of zirconia dental implants based on an updated systematic literature review. ...
Surface roughness and optical characteristics evaluations after chairside adjustment of different zirconia types
Surface roughness and optical characteristics evaluations after chairside adjustment of different zirconia types
AbstractStatement of ProblemLimited evidence is available for the effect of chairside adjustment using rotary cutting instruments on the surface roughness and optical properties of...
The Performance of PEKK vs Zirconia Abutments for Screw-Retained Crowns in Two-Piece Zirconia Implants: An in vitro Study
The Performance of PEKK vs Zirconia Abutments for Screw-Retained Crowns in Two-Piece Zirconia Implants: An in vitro Study
This study aimed to compare the in vitro performance of anterior and posterior crowns with screw-retained polyetherketoneketone (PEKK) or zirconia abutments on two-piece zirconia i...
Synthetization and Characterization of Yttria Stabilized Zirconia Powder from Amang Zircon Sand
Synthetization and Characterization of Yttria Stabilized Zirconia Powder from Amang Zircon Sand
Zirconia is widely used in industry as it exhibits high strength and amazing properties. However, pure zirconia powder is often unstable to be used in high temperature applications...
Assessment of cranial reconstruction utilizing various implant materials: finite element study
Assessment of cranial reconstruction utilizing various implant materials: finite element study
AbstractThe human head can sometimes experience impact loads that result in skull fractures or other injuries, leading to the need for a craniectomy. Cranioplasty is a procedure th...
The digital workflow in implant dentistry
The digital workflow in implant dentistry
Inserting dental implants to replace missing teeth is a well-established treatment concept. New digital developments are being introduced rapidly and are supposed to improve this a...
Marginal Bone Loss and Aesthetics Around Zirconia and Titanium Dental Implants-A Metanalysis
Marginal Bone Loss and Aesthetics Around Zirconia and Titanium Dental Implants-A Metanalysis
AIM: To evaluate and compare the marginal bone loss and aesthetic outcomes of zirconia implants with titanium implants in randomized controlled trials (RCTs). MATERIAL AND METHODS:...

Back to Top