Javascript must be enabled to continue!
Methodological determinants of signal quality in electrobulbogram recordings
View through CrossRef
Abstract
The electrobulbogram (EBG) is a new, non-invasive method for measuring the functional activity of the human olfactory bulb (OB). To date, the EBG has been used to assess how the OB process odor identity, valence, intensity, and it has shown promise as an early biomarker for Parkinson’s disease. However, current implementation of the EBG method depends on several methodological components, including subject specific co-registration of electrode positions through neuronavigation and EEG source reconstruction, which may limit accessibility for many research groups. In this study, we test the quality and reliability of the OB signal under different configurations to potentially remedy this. Specifically, we compare six EBG setups that vary in the use of subject-specific T1 scans versus a template head model, co-registered versus template electrode positions, and individualized versus template-based OB location. Our results indicate that strongest EBG signals are obtained when using subject-specific T1 scans in combination with co-registered electrode positions. However, we obtained significant EBG activity even when using a fully template-based configuration. Our anatomical analysis of OB location of 941 individuals reveals that in 86% of cases, the OB is centered within the spatial resolution bounds of the EEG source dipole, supporting the feasibility of detecting olfactory bulb signals without precise individual anatomical mapping using template coordinates. These findings suggest that while subject-specific configurations enhance signal quality, the EBG method remains robust enough to yield meaningful results even with less complex setups. This enables a broader adoption of the EBG method in both clinical and research settings.
Title: Methodological determinants of signal quality in electrobulbogram recordings
Description:
Abstract
The electrobulbogram (EBG) is a new, non-invasive method for measuring the functional activity of the human olfactory bulb (OB).
To date, the EBG has been used to assess how the OB process odor identity, valence, intensity, and it has shown promise as an early biomarker for Parkinson’s disease.
However, current implementation of the EBG method depends on several methodological components, including subject specific co-registration of electrode positions through neuronavigation and EEG source reconstruction, which may limit accessibility for many research groups.
In this study, we test the quality and reliability of the OB signal under different configurations to potentially remedy this.
Specifically, we compare six EBG setups that vary in the use of subject-specific T1 scans versus a template head model, co-registered versus template electrode positions, and individualized versus template-based OB location.
Our results indicate that strongest EBG signals are obtained when using subject-specific T1 scans in combination with co-registered electrode positions.
However, we obtained significant EBG activity even when using a fully template-based configuration.
Our anatomical analysis of OB location of 941 individuals reveals that in 86% of cases, the OB is centered within the spatial resolution bounds of the EEG source dipole, supporting the feasibility of detecting olfactory bulb signals without precise individual anatomical mapping using template coordinates.
These findings suggest that while subject-specific configurations enhance signal quality, the EBG method remains robust enough to yield meaningful results even with less complex setups.
This enables a broader adoption of the EBG method in both clinical and research settings.
Related Results
If I Had Possession over Judgment Day: Augmenting Robert Johnson
If I Had Possession over Judgment Day: Augmenting Robert Johnson
augmentvb [ɔːgˈmɛnt]1. to make or become greater in number, amount, strength, etc.; increase2. Music: to increase (a major or perfect interval) by a semitone (Collins English Dicti...
Insufficient quality of public automated external defibrillator recordings in the greater Paris area, a descriptive study
Insufficient quality of public automated external defibrillator recordings in the greater Paris area, a descriptive study
BackgroundWestern countries report a significant increase in the proportion of patients who experience out-of-hospital cardiac arrests (OHCAs) and benefit from a public automated e...
Extractraction of non-stationary harmonic from chaotic background based on synchrosqueezed wavelet transform
Extractraction of non-stationary harmonic from chaotic background based on synchrosqueezed wavelet transform
The signal detection in chaotic background has gradually become one of the research focuses in recent years. Previous research showed that the measured signals were often unavoidab...
Playing in the Manner of Ricardo Viñes
Playing in the Manner of Ricardo Viñes
Playing in the Manner of Ricardo Viñes is an artistic research project undertaken at the Norwegian University of Science and Technology (NTNU) for the degree of Philosophiae Doctor...
Potable Water Sources, Household Hygiene, and Sanitation Practices in Ikpoba Okha LGA, Edo State: Implications for Public Health and Sustainable Water Management
Omoregie, Andrew Edosa.1 Omoregie Abieyuwa Peace2 Okoro, Enyinnaya Okoro.3
1 College of Medi
Potable Water Sources, Household Hygiene, and Sanitation Practices in Ikpoba Okha LGA, Edo State: Implications for Public Health and Sustainable Water Management
Omoregie, Andrew Edosa.1 Omoregie Abieyuwa Peace2 Okoro, Enyinnaya Okoro.3
1 College of Medi
BACKGROUND
Access to potable drinking water and sufficient sanitation continues to be an urgent global concern, particularly in developing regions where con...
Double resonant sum-frequency generation in an external-cavity under high-efficiency frequency conversion
Double resonant sum-frequency generation in an external-cavity under high-efficiency frequency conversion
In recent years, more than 90% of the signal laser power can be up-converted based on the high-efficiency double resonant external cavity sum-frequency generation (SFG), especially...
A qualitative exploration of the determinants of youth violence using participatory action research: a Sri Lankan study
A qualitative exploration of the determinants of youth violence using participatory action research: a Sri Lankan study
Abstract
Background
Youth violence is a significant health issue mainly in low and middle-income countries (LMICs). Violence is growing among Sri Lankan youth, yet research...
SongBeam: an automated recorder using beamforming to make high-quality recordings
SongBeam: an automated recorder using beamforming to make high-quality recordings
Recording bird song can provide information about birds’ presence, behaviour and ecology. As such, automated recording units are excellent data collection tools for bioacousticians...

