Javascript must be enabled to continue!
Determination of individual values of four-element equivalent circuits elements parameters at technical diagnostics of insulation by absorption methods
View through CrossRef
The aim of this article is to present a methodology of determining of the individual values of the parameters of four-element equivalent circuits for insulation with through conductivity. Methodology. The proposed method consists in the fact that at a time interval of more than 10 s, when the charge indicator no longer contributes to the leakage current, three points t1, t2 and t3 are selected, such that t2 – t1 = t3 – t2. To be able to determine the absorption coefficient R60/R15, it is recommended to take t1 = 15 s, t2 = 37.5 s and t3 = 60 s. At the same time, by subtracting I(t2) – I(t1) and I(t3) – I(t2), the constant component of the absorption curve is excluded and it becomes possible to determine the individual values of the parameters of the generalized equivalent circuit of insulation, additionally using its conductivity in operator form. Results. As calculations show, the correct determination of the parameters of insulation equivalent circuit according to the proposed method is possible only with a certain ratio of these parameters. The charge time of the geometric capacitance Cg(R0+Rd), where R0 and Rd are the resistance that forms the charging exponent, and the resistance of the sensor, should be within 0.2 s <Cg(R0+Rd)<1 s, the time constant CaRa, where Ca and Ra are the capacitance and resistance of the absorption chain, should be more than 3 s, the product of CgRl, where Rl is the leakage resistance, more 0.5 s, the leakage resistance Rl is less than the absorption resistance Ra. Checking the methodology on a model example gives the values of the parameters of the insulation equivalent circuit that match the specified ones with high accuracy. Practical value. The use of individual values of the parameters of insulation equivalent circuits when applying absorption diagnostic methods with considering the time values and dimensional factors, allow to calculate all currently used diagnostic parameters, to determine the conditions of certain insulation types, as well as in more detail, in comparison with the existing approach, to assess the technical condition of the insulation and the reasons of its changes.
National Technical University Kharkiv Polytechnic Institute
Title: Determination of individual values of four-element equivalent circuits elements parameters at technical diagnostics of insulation by absorption methods
Description:
The aim of this article is to present a methodology of determining of the individual values of the parameters of four-element equivalent circuits for insulation with through conductivity.
Methodology.
The proposed method consists in the fact that at a time interval of more than 10 s, when the charge indicator no longer contributes to the leakage current, three points t1, t2 and t3 are selected, such that t2 – t1 = t3 – t2.
To be able to determine the absorption coefficient R60/R15, it is recommended to take t1 = 15 s, t2 = 37.
5 s and t3 = 60 s.
At the same time, by subtracting I(t2) – I(t1) and I(t3) – I(t2), the constant component of the absorption curve is excluded and it becomes possible to determine the individual values of the parameters of the generalized equivalent circuit of insulation, additionally using its conductivity in operator form.
Results.
As calculations show, the correct determination of the parameters of insulation equivalent circuit according to the proposed method is possible only with a certain ratio of these parameters.
The charge time of the geometric capacitance Cg(R0+Rd), where R0 and Rd are the resistance that forms the charging exponent, and the resistance of the sensor, should be within 0.
2 s <Cg(R0+Rd)<1 s, the time constant CaRa, where Ca and Ra are the capacitance and resistance of the absorption chain, should be more than 3 s, the product of CgRl, where Rl is the leakage resistance, more 0.
5 s, the leakage resistance Rl is less than the absorption resistance Ra.
Checking the methodology on a model example gives the values of the parameters of the insulation equivalent circuit that match the specified ones with high accuracy.
Practical value.
The use of individual values of the parameters of insulation equivalent circuits when applying absorption diagnostic methods with considering the time values and dimensional factors, allow to calculate all currently used diagnostic parameters, to determine the conditions of certain insulation types, as well as in more detail, in comparison with the existing approach, to assess the technical condition of the insulation and the reasons of its changes.
Related Results
Reasoning of additional diagnostic parameters for electric insulation diagnostics by absorption methods
Reasoning of additional diagnostic parameters for electric insulation diagnostics by absorption methods
The aim of this work is to analyze the inadequacies of the diagnostic parameters, in particular the absorption and polarization coefficients, which are manifested in their integral...
Thermal Performance and Building Energy Simulation of Precast Insulation Walls in Two Climate Zones
Thermal Performance and Building Energy Simulation of Precast Insulation Walls in Two Climate Zones
Traditional concrete buildings exhibit low energy consumption and high heat loss, which results in a larger environmental problem. Precast insulation walls are proposed for strengt...
ČVRSTA IZOLACIJA ENERGETSKIH TRANSFOMATORA – STRUKTURA, PRIMENSKE OSOBINE I METODE ISPITIVANjA NAKON FABRIČKOG SUŠENjA I TOKOM EKSPLOATACIJE
ČVRSTA IZOLACIJA ENERGETSKIH TRANSFOMATORA – STRUKTURA, PRIMENSKE OSOBINE I METODE ISPITIVANjA NAKON FABRIČKOG SUŠENjA I TOKOM EKSPLOATACIJE
Transformers are vital components in electricity transmission and distribution systems. The lifetime of transformers is limited by the lifetime of solid insulation, which is mostly...
Feasibility of Plasmonic Circuits Merged with Silicon Integrated Circuits
Feasibility of Plasmonic Circuits Merged with Silicon Integrated Circuits
ABSTRACT
Plasmonic signal transmission via nanoscale plasmonic waveguides is a new technique with the potential to increase the information transfer capacity in s...
Technical Analysis in Financial Markets
Technical Analysis in Financial Markets
The efficient markets hypothesis states that in highly competitive and developed markets it is impossible to derive a trading strategy that can generate persistent excess profits a...
Autonomy on Trial
Autonomy on Trial
Photo by CHUTTERSNAP on Unsplash
Abstract
This paper critically examines how US bioethics and health law conceptualize patient autonomy, contrasting the rights-based, individualist...
Corrosion Under Insulation: Detection and Rectification
Corrosion Under Insulation: Detection and Rectification
Abstract
Corrosion Under Insulation (CUI) is a critical issue in the oil and gas sector, specifically in industrial piping systems. The conventional assessment metho...
Decarbonizing Through Building Thermal Insulation - Coconut Fiber Impact
Decarbonizing Through Building Thermal Insulation - Coconut Fiber Impact
One of the major global issues threatening the survival of mankind is the effects of global warming exacerbated by the increasing production of carbon dioxide emissions. The global...