Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

SU‐FF‐I‐53: X‐Ray Scattering and Fluorescence Spectroscopy as a Possible Tool for KVp Monitoring

View through CrossRef
Small changes in the peak voltage of a diagnostic x‐ray tube can cause significant modifications in the absorbed dose or degrade the contrast of an x‐ray image. It has been suggested that kVp should be monitored routinely however a standardized noninvasive technique for kVp monitoring has yet to be developed. A number of x‐ray beam‐related quantities depend upon the endpoint energy including, intensity, penetrability and dosage. However, none of these parameters can be used to determine kVp for x‐ray tubes in general.If a material is irradiated by an x‐ray beam, spectra for Compton scattered photons as well as x‐ray fluorescence lines that are a characteristic of the target material can be simultaneously collected. The ratio of the integral number of Compton scattered photons and the number of fluorescent x‐ray photons is a function of the maximal beam energy and same time independent of the tube current, measurement geometry, and other quantities that are related to the experimental setup.CdTe detectors having sufficient energy resolution to distinguish individual x‐ray fluorescence lines and high efficiency for energies in the 10‐keV region were used in our measurements. Several materials covering a wide range of atomic numbers from Copper (Z=12) to lead (Z=82) were used as the medium for fluorescence and for scattering. A variety of scattering angles and detection geometries were tested.Our measurements have demonstrated that the ratio of the integral number of Compton scattered photons to that of fluorescent photons using a fixed geometry is a sensitive index of kVp (peak tube voltage).
Title: SU‐FF‐I‐53: X‐Ray Scattering and Fluorescence Spectroscopy as a Possible Tool for KVp Monitoring
Description:
Small changes in the peak voltage of a diagnostic x‐ray tube can cause significant modifications in the absorbed dose or degrade the contrast of an x‐ray image.
It has been suggested that kVp should be monitored routinely however a standardized noninvasive technique for kVp monitoring has yet to be developed.
A number of x‐ray beam‐related quantities depend upon the endpoint energy including, intensity, penetrability and dosage.
However, none of these parameters can be used to determine kVp for x‐ray tubes in general.
If a material is irradiated by an x‐ray beam, spectra for Compton scattered photons as well as x‐ray fluorescence lines that are a characteristic of the target material can be simultaneously collected.
The ratio of the integral number of Compton scattered photons and the number of fluorescent x‐ray photons is a function of the maximal beam energy and same time independent of the tube current, measurement geometry, and other quantities that are related to the experimental setup.
CdTe detectors having sufficient energy resolution to distinguish individual x‐ray fluorescence lines and high efficiency for energies in the 10‐keV region were used in our measurements.
Several materials covering a wide range of atomic numbers from Copper (Z=12) to lead (Z=82) were used as the medium for fluorescence and for scattering.
A variety of scattering angles and detection geometries were tested.
Our measurements have demonstrated that the ratio of the integral number of Compton scattered photons to that of fluorescent photons using a fixed geometry is a sensitive index of kVp (peak tube voltage).

Related Results

Validation of kVp measurement using the HVL approach for standard beam qualities for mammography
Validation of kVp measurement using the HVL approach for standard beam qualities for mammography
Abstract In mammography imaging, the most common target material used in mammography machines are Molybdenum (Mo) target with Mo filters. In the publication of Inter...
Estimasi Resiko Radiasi Janin pada Pemeriksaan Radiografi Pelvis
Estimasi Resiko Radiasi Janin pada Pemeriksaan Radiografi Pelvis
Sinar-X merupakan sumber radiasi pengion yang paling banyak digunakan untuk pemeriksaan diagnostik dalam aplikasi klinik. Radiasi pengion memang memberikan manfaat yang besar dalam...
OPTIMIZATION OF RADIATION DOSE AND IMAGE QUALITY IN ABDOMINAL RADIOGRAPHY USING DIGITAL MOBILE X-RAY SYSTEM
OPTIMIZATION OF RADIATION DOSE AND IMAGE QUALITY IN ABDOMINAL RADIOGRAPHY USING DIGITAL MOBILE X-RAY SYSTEM
The abdominal radiography using digital mobile x-ray system is commonly requested for the immobilized patient. The selection of the exposure parameters needs the experience of the ...
Voltage Dependent Effect of Spiral Wound Plasma Discharge on DBC1.2 Cellular Integrity
Voltage Dependent Effect of Spiral Wound Plasma Discharge on DBC1.2 Cellular Integrity
Low temperature plasmas (LTPs) generated at atmospheric pressure and room temperature have gained increasing attention in biomedical research due to their ability to control cellul...
Applications of Total Scanning Fluorescence to Exploration Geochemistry
Applications of Total Scanning Fluorescence to Exploration Geochemistry
ABSTRACT A total scanning fluorescence technique is described for correlation (oil/oil and oil/source rock) and surface geochemical prospecting studies. The fluor...
Optimising tool wear and workpiece condition monitoring via cyber-physical systems for smart manufacturing
Optimising tool wear and workpiece condition monitoring via cyber-physical systems for smart manufacturing
Smart manufacturing has been developed since the introduction of Industry 4.0. It consists of resource sharing and networking, predictive engineering, and material and data analyti...
Measurement of scattering intensity distribution of single microparticles/nanoclusters based on laser levitation
Measurement of scattering intensity distribution of single microparticles/nanoclusters based on laser levitation
The scattering measurement of particulates in gaseous medium is helpful in understanding light transmission, laser detection, combustion radiation and atmospheric environment. In o...

Back to Top