Javascript must be enabled to continue!
A novel three-channel endorectal coil for prostate magnetic resonance imaging at 3T
View through CrossRef
We designed and fabricated a novel three-channel endorectal prostate coil and validated its feasibility of high-resolution magnetic resonance imaging (MRI) at 3T. A commercial 3T surface coil was used for comparison. Both phantom imaging and in-vivo prostate imaging show that the 3-channel endorectal coil provides an improved SNR than the external surface coil. Prostate images at resolution of 0.47 mm × 0.47 mm × 4.0 mm are acquired using the 3-channel endorectal coil to demonstrate the performance. With the improved SNR and multichannel design, the proposed endorectal coil could enable parallel imaging based fast imaging in prostate imaging studies.
Title: A novel three-channel endorectal coil for prostate magnetic resonance imaging at 3T
Description:
We designed and fabricated a novel three-channel endorectal prostate coil and validated its feasibility of high-resolution magnetic resonance imaging (MRI) at 3T.
A commercial 3T surface coil was used for comparison.
Both phantom imaging and in-vivo prostate imaging show that the 3-channel endorectal coil provides an improved SNR than the external surface coil.
Prostate images at resolution of 0.
47 mm × 0.
47 mm × 4.
0 mm are acquired using the 3-channel endorectal coil to demonstrate the performance.
With the improved SNR and multichannel design, the proposed endorectal coil could enable parallel imaging based fast imaging in prostate imaging studies.
Related Results
Abstract 5758: Deletions of olfactomedin 4 gene is associated with progression of prostate cancer
Abstract 5758: Deletions of olfactomedin 4 gene is associated with progression of prostate cancer
Abstract
The human olfactomedin 4 gene (OLFM4) encodes an olfactomedin-related glycoprotein, which our group first cloned and characterized in myeloid cells and mapp...
Holmium laser enucleation of the prostate versus bipolar transurethral enucleation of the prostate in management of benign prostatic hyperplasia: A randomized controlled trial
Holmium laser enucleation of the prostate versus bipolar transurethral enucleation of the prostate in management of benign prostatic hyperplasia: A randomized controlled trial
Objective
To evaluate the safety, efficacy and cost‐effectiveness of holmium enucleation of the prostate and bipolar transurethral enucleation of the prostate.
...
En skvatmølle i Ljørring
En skvatmølle i Ljørring
A Horizontal Mill at Ljørring, Jutland.Horizontal water-mills have been in use in Jutland since the beginning of the Christian era 2). But the one here described shows so close a c...
SU‐FF‐J‐30: Simultaneous Use of An Implanted Fiducial System and An Endorectal Balloon for the Treatment of Prostate Cancer
SU‐FF‐J‐30: Simultaneous Use of An Implanted Fiducial System and An Endorectal Balloon for the Treatment of Prostate Cancer
Purpose: To report on our initial experience of using an on‐line implanted fiducial system simultaneously with an endorectal balloon to treat patients with prostate cancer. Method ...
Abstract 4602: Clinicopathological and genetic features of prostate cancer in Algerian patients: First report
Abstract 4602: Clinicopathological and genetic features of prostate cancer in Algerian patients: First report
Abstract
Background: Prostate cancer is the second most frequent malignancy (after lung cancer) in men worldwide. It is the third most common cancer in men in Algeri...
E-019 Novel bioactive coil with modified PGLA
E-019 Novel bioactive coil with modified PGLA
PurposeNovel Bioactive Coil with modified PGLA was developed to further improve biological reaction induced by currently available PGLA coils.MethodPrototype coil materials were pr...
Correlation between Prostate-Specific Antigen Levels and Prostate Imaging Reporting and Data System score: A Retrospective Study
Correlation between Prostate-Specific Antigen Levels and Prostate Imaging Reporting and Data System score: A Retrospective Study
Introduction: Prostate cancer is a prevalent and potentially lethal malignancy affecting men worldwide. To enhance early detection and accurate risk stratification, various diagnos...
Signal-to-Noise Ratio and Contrast-to-Noise Ratio Comparisons Between a Wireless Volume Radiofrequency Coil and a Commercially Available Wired Radiofrequency Coil
Signal-to-Noise Ratio and Contrast-to-Noise Ratio Comparisons Between a Wireless Volume Radiofrequency Coil and a Commercially Available Wired Radiofrequency Coil
The design of magnetic resonance imaging (MRI) radiofrequency (RF) coils plays a critical role in determining image quality, with signal-to-noise ratio (SNR) and contrast-to-noise ...

