Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

A Phase Error Correction System for Bioimpedance Measurement Circuits

View through CrossRef
Bioimpedance sensing is widely used across a spectrum of biomedical applications. Among the different system architectures for measuring tissue impedance, synchronous detection or demodulation (SD) stands out for its lock-in amplifier utilising in-phase (I) and quadrature (Q) demodulation signals to derive real and imaginary impedance components. Typically, the current injected into the tissue is controlled by a voltage-controlled current source (VCCS). However, the VCCS can introduce phase shifts leading to discrepancies in real/imaginary outputs, especially at the highest end of the operating frequency bandwidth. Such discrepancies can significantly impact diagnostic accuracy in applications reliant on precise tissue phase profiling, such as cancer and neuromuscular evaluations. In the present work, we propose an automatic phase error compensation stage for bioimpedance measurement systems to minimise this systematic error. Our experimental findings demonstrated a considerable reduction in phase error, with the Phase Error Compensated Synchronous Detection (PECSD) system exhibiting a maximum phase error of 2° (≤5% error) compared with the uncompensated SD system where error exceeded 20%. The improvements made by our proposed SD system hold great potential for enhancing the accuracy of impedance measurements, particularly in clinical diagnosis and disease detection.
Title: A Phase Error Correction System for Bioimpedance Measurement Circuits
Description:
Bioimpedance sensing is widely used across a spectrum of biomedical applications.
Among the different system architectures for measuring tissue impedance, synchronous detection or demodulation (SD) stands out for its lock-in amplifier utilising in-phase (I) and quadrature (Q) demodulation signals to derive real and imaginary impedance components.
Typically, the current injected into the tissue is controlled by a voltage-controlled current source (VCCS).
However, the VCCS can introduce phase shifts leading to discrepancies in real/imaginary outputs, especially at the highest end of the operating frequency bandwidth.
Such discrepancies can significantly impact diagnostic accuracy in applications reliant on precise tissue phase profiling, such as cancer and neuromuscular evaluations.
In the present work, we propose an automatic phase error compensation stage for bioimpedance measurement systems to minimise this systematic error.
Our experimental findings demonstrated a considerable reduction in phase error, with the Phase Error Compensated Synchronous Detection (PECSD) system exhibiting a maximum phase error of 2° (≤5% error) compared with the uncompensated SD system where error exceeded 20%.
The improvements made by our proposed SD system hold great potential for enhancing the accuracy of impedance measurements, particularly in clinical diagnosis and disease detection.

Related Results

Accuracy of Bioimpedance Modalities for Fluid Assessment in Hemodialysis Patients: A Randomized Observational Study
Accuracy of Bioimpedance Modalities for Fluid Assessment in Hemodialysis Patients: A Randomized Observational Study
Aim Fluid overload is a major contributor to mortality in critically ill patients but is difficult to estimate clinically. Bioimpedance has been used to estimate fluid volumes with...
The effect of heart pulsatile on the measurement of artery bioimpedance
The effect of heart pulsatile on the measurement of artery bioimpedance
Abstract Bioimpedance is an electrical property, which is measured to indicate related parameters and diagnose several diseases of the body. The heart pulsatile is a...
Deep Learning Phase Error Correction for Cerebrovascular 4D Flow MRI
Deep Learning Phase Error Correction for Cerebrovascular 4D Flow MRI
Abstract Background and Purpose Background phase errors in 4D Flow MRI may negatively impact blood flow quantification. In this study, we assessed their impact on cerebrov...
New Generation of Electronic Components and How They Influence Printed Circuit Boards
New Generation of Electronic Components and How They Influence Printed Circuit Boards
The approach to reduce the costs of electronic circuits will be the transition of LSI‐circuits to VLSI‐circuits, introducing another order of magnitude to the complexity and densit...
Determination of Cardiac Output by Peripheral Electrical Bioimpedance
Determination of Cardiac Output by Peripheral Electrical Bioimpedance
This paper presents the noninvasive determination of cardiac output by peripheral electrical bioimpedance. We validate our approach first with small animals and then with human. We...
Static structural system identification using observability method
Static structural system identification using observability method
During the construction and operation stages of structures, various factors lead to irreversible degradation that could affect the normal use and the public safety of these structu...
Técnicas de reconstrucción y compensación activa de frentes de onda complejos
Técnicas de reconstrucción y compensación activa de frentes de onda complejos
The continuous improvements of optical design tools and manufacturing technologies of free-form optical elements, allow the creation of new complex-shaped lenses that improve the p...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...

Back to Top