Javascript must be enabled to continue!
The effect of heart pulsatile on the measurement of artery bioimpedance
View through CrossRef
Abstract
Bioimpedance is an electrical property, which is measured to indicate related parameters and diagnose several diseases of the body. The heart pulsatile is a blood flow with periodic variations as a result of heart beats. The main objective of this article is studying the effect of the heart pulsatile on the measurements of artery bioimpedance. However, neglecting the heart pulsatile leads to error in calculations of many applications based on artery bioimpedance measurement such as glucose monitoring, stenosis, and cholesterol detection. Furthermore, the studying of the heart pulsatile effect could be developed to measure the heart rate as a novel method based on bioimpedance phenomena. A simple model of electrodes and composite layers (skin, fat, muscle, and artery) is simulated using COMSOL. In this work, a model of noninvasive electrodes for measuring an artery bioimpedance is described to show the best method to take into consideration the effect of heart pulsatile.
Walter de Gruyter GmbH
Title: The effect of heart pulsatile on the measurement of artery bioimpedance
Description:
Abstract
Bioimpedance is an electrical property, which is measured to indicate related parameters and diagnose several diseases of the body.
The heart pulsatile is a blood flow with periodic variations as a result of heart beats.
The main objective of this article is studying the effect of the heart pulsatile on the measurements of artery bioimpedance.
However, neglecting the heart pulsatile leads to error in calculations of many applications based on artery bioimpedance measurement such as glucose monitoring, stenosis, and cholesterol detection.
Furthermore, the studying of the heart pulsatile effect could be developed to measure the heart rate as a novel method based on bioimpedance phenomena.
A simple model of electrodes and composite layers (skin, fat, muscle, and artery) is simulated using COMSOL.
In this work, a model of noninvasive electrodes for measuring an artery bioimpedance is described to show the best method to take into consideration the effect of heart pulsatile.
Related Results
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Abstract
Introduction
Coronary subclavian steal syndrome (CSSS) is a rare phenomenon that often goes undiagnosed and causes severe complications, including death. This report prese...
Multilinear Regression Analysis between Local Bioimpedance Spectroscopy and Fish Morphological Parameters
Multilinear Regression Analysis between Local Bioimpedance Spectroscopy and Fish Morphological Parameters
Repeated fish handling may cause stress, which biases experiments and so affects the results. In order to reduce this, the present study investigates the benefit of using bioimpeda...
A rare case report of subscapular artery
A rare case report of subscapular artery
Axillary artery is one of the most important arteries of the upper limb, which is a continua- tion of the subclavian artery. It begins at the lateral border of the first rib and en...
Accuracy of Bioimpedance Modalities for Fluid Assessment in Hemodialysis Patients: A Randomized Observational Study
Accuracy of Bioimpedance Modalities for Fluid Assessment in Hemodialysis Patients: A Randomized Observational Study
Aim Fluid overload is a major contributor to mortality in critically ill patients but is difficult to estimate clinically. Bioimpedance has been used to estimate fluid volumes with...
Pulsatile Right Ventricle to Pulmonary Artery Extracorporeal Membrane Oxygenation in a Pigs
Pulsatile Right Ventricle to Pulmonary Artery Extracorporeal Membrane Oxygenation in a Pigs
Background: We investigated the impact of right ventricle to pulmonary artery extracorporeal membrane oxygenation in acute respiratory dysfunction with or without pulsatile flow. ...
Pulsatile Tinnitus and the Intrameatal Vascular Loop: Why Do We Not Hear Our Carotids?
Pulsatile Tinnitus and the Intrameatal Vascular Loop: Why Do We Not Hear Our Carotids?
Abstract
OBJECTIVE:
Pulsatile tinnitus is characterized by hearing the heart beat or respiration in one or both ears. In 15% of ...
Absence of Steroid-Dependent, Endogenous Opioid Peptide Suppression of Pulsatile Luteinizing Hormone Release between Diestrus 1 and Diestrus 2 in the Rat Estrous Cycle
Absence of Steroid-Dependent, Endogenous Opioid Peptide Suppression of Pulsatile Luteinizing Hormone Release between Diestrus 1 and Diestrus 2 in the Rat Estrous Cycle
The objective of this study was to determine whether the negative feedback action of ovarian steroids on pulsatile luteinizing hormone (LH) release in the diestrous 1 (Dl)-diestrou...
Comparison between Ethylcellulose Aqueous Colloidal Dispersion and Ethylcellulose Ethanolic Solution as Rupturable Coating Materials for Pulsatile Release Tablets
Comparison between Ethylcellulose Aqueous Colloidal Dispersion and Ethylcellulose Ethanolic Solution as Rupturable Coating Materials for Pulsatile Release Tablets
Pulsatile release dosage forms which time of drug release can be determined have shown advantages for various drugs such as chronopharmacological drugs and drugs with high first pa...

