Javascript must be enabled to continue!
A 3 MHz Low-Error Adaptive Howland Current Source for High-Frequency Bioimpedance Applications
View through CrossRef
Bioimpedance is a diagnostic sensing method used in medical applications, ranging from body composition assessment to detecting skin cancer. Commonly, discrete-component (and at times integrated) circuit variants of the Howland Current Source (HCS) topology are employed for injection of an AC current. Ideally, its amplitude should remain within 1% of its nominal value across a frequency range, and that nominal value should be programmable. However, the method’s applicability and accuracy are hindered due to the current amplitude diminishing at frequencies above 100 kHz, with very few designs accomplishing 1 MHz, and only at a single nominal amplitude. This paper presents the design and implementation of an adaptive current source for bioimpedance applications employing automatic gain control (AGC). The “Adaptive Howland Current Source” (AHCS) was experimentally tested, and the results indicate that the design can achieve less than 1% amplitude error for both 1 mA and 100 µA currents for bandwidths up to 3 MHz. Simulations also indicate that the system can be designed to achieve up to 19% noise reduction relative to the most common HCS design. AHCS addresses the need for high bandwidth AC current sources in bioimpedance spectroscopy, offering automatic output current compensation without constant recalibration. The novel structure of AHCS proves crucial in applications requiring higher β-dispersion frequencies exceeding 1 MHz, where greater penetration depths and better cell status assessment can be achieved, e.g., in the detection of skin or breast cancer.
Title: A 3 MHz Low-Error Adaptive Howland Current Source for High-Frequency Bioimpedance Applications
Description:
Bioimpedance is a diagnostic sensing method used in medical applications, ranging from body composition assessment to detecting skin cancer.
Commonly, discrete-component (and at times integrated) circuit variants of the Howland Current Source (HCS) topology are employed for injection of an AC current.
Ideally, its amplitude should remain within 1% of its nominal value across a frequency range, and that nominal value should be programmable.
However, the method’s applicability and accuracy are hindered due to the current amplitude diminishing at frequencies above 100 kHz, with very few designs accomplishing 1 MHz, and only at a single nominal amplitude.
This paper presents the design and implementation of an adaptive current source for bioimpedance applications employing automatic gain control (AGC).
The “Adaptive Howland Current Source” (AHCS) was experimentally tested, and the results indicate that the design can achieve less than 1% amplitude error for both 1 mA and 100 µA currents for bandwidths up to 3 MHz.
Simulations also indicate that the system can be designed to achieve up to 19% noise reduction relative to the most common HCS design.
AHCS addresses the need for high bandwidth AC current sources in bioimpedance spectroscopy, offering automatic output current compensation without constant recalibration.
The novel structure of AHCS proves crucial in applications requiring higher β-dispersion frequencies exceeding 1 MHz, where greater penetration depths and better cell status assessment can be achieved, e.
g.
, in the detection of skin or breast cancer.
Related Results
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Accuracy of Bioimpedance Modalities for Fluid Assessment in Hemodialysis Patients: A Randomized Observational Study
Accuracy of Bioimpedance Modalities for Fluid Assessment in Hemodialysis Patients: A Randomized Observational Study
Aim Fluid overload is a major contributor to mortality in critically ill patients but is difficult to estimate clinically. Bioimpedance has been used to estimate fluid volumes with...
The effect of heart pulsatile on the measurement of artery bioimpedance
The effect of heart pulsatile on the measurement of artery bioimpedance
Abstract
Bioimpedance is an electrical property, which is measured to indicate related parameters and diagnose several diseases of the body. The heart pulsatile is a...
Strategi Refarming Frekuensi 1800 MHz Untuk Implementasi LTE di Indonesia
Strategi Refarming Frekuensi 1800 MHz Untuk Implementasi LTE di Indonesia
LTE adalah teknologi yang digunakan dalam generasi keempat dengan arsitektur yang lebih sederhana dan semua berbasis IP (Internet Protocol). Teknologi baru ini membutuhkan spektrum...
A Phase Error Correction System for Bioimpedance Measurement Circuits
A Phase Error Correction System for Bioimpedance Measurement Circuits
Bioimpedance sensing is widely used across a spectrum of biomedical applications. Among the different system architectures for measuring tissue impedance, synchronous detection or ...
Determination of Cardiac Output by Peripheral Electrical Bioimpedance
Determination of Cardiac Output by Peripheral Electrical Bioimpedance
This paper presents the noninvasive determination of cardiac output by peripheral electrical bioimpedance. We validate our approach first with small animals and then with human. We...
Ultra-broadband multi-tone frequency measurement based on the recirculating frequency shift of a frequency modulated continuous wave
Ultra-broadband multi-tone frequency measurement based on the recirculating frequency shift of a frequency modulated continuous wave
We proposed an ultra-broadband multi-tone frequency measurement (FM) approach based on frequency modulated continuous wave (FMCW). This work aims to achieve wide-range multi-tone F...
Adaptive Active Disturbance Rejection Control for Vehicle Steer-by-Wire under Communication Time Delays
Adaptive Active Disturbance Rejection Control for Vehicle Steer-by-Wire under Communication Time Delays
In this paper, an adaptive active disturbance rejection control is newly designed for precise angular steering position tracking of the uncertain and nonlinear SBW system with time...

