Optimal endotracheal cuff pressure in the intensive care setting: A pilot study

View through CrossRef
Abstract Background: Endotracheal tube cuff pressure is clinically measured by “minimal occlusion (MOC) and minimal leak (MLK) techniques” by palpating and auscultating the neck for end-inspiratory “elimination” or “allowance” of subtle air leak, respectively. This study was done to determine the validity and reliability of MOC and MLK techniques, manometric endotracheal tube cuff-pressure measurement of 20–30 cm H2O being reference standard. Materials and Methods: A prospective, observational study was conducted in adult patients requiring positive pressure ventilation in the medical intensive care unit (ICU). Two investigators independently assessed MOC and MLK twice on days 2 and 3 of intubation. ICU registrar, unaware of earlier readings, noted manometric cuff-pressure within 5 min. Inter-observer reliability was calculated using intraclass correlation coeffiient (ICC). Validity of measurement was assessed using accepted reference standard of 20–30 cm H2O by manometer. Results: Sixty patients between 17 and 82 years, on positive pressure ventilation were evaluated twice, by two investigators resulting in 240 observations. Mean manometric pressures were 15.7 + 2.6 and 12.2 + 2.4 cm H2O using MOC and MLK techniques to maintain adequate ventilation. ICC measured for reliability was high at 0.69 and 0.67 for MOC and MLK techniques. Adequate ventilation was maintained in all patients and 57 of 60 (95%) were discharged alive without significant ventilatory complications. Conclusions: Cuff pressures needed to maintain effective positive pressure ventilation was well below the accepted levels of 20–30 cm of H2O in majority patients. MOC and MLK techniques have high reliability. The result of the study has the implications on ICU ventilatory care.
Title: Optimal endotracheal cuff pressure in the intensive care setting: A pilot study
Description:
Abstract Background: Endotracheal tube cuff pressure is clinically measured by “minimal occlusion (MOC) and minimal leak (MLK) techniques” by palpating and auscultating the neck for end-inspiratory “elimination” or “allowance” of subtle air leak, respectively.
This study was done to determine the validity and reliability of MOC and MLK techniques, manometric endotracheal tube cuff-pressure measurement of 20–30 cm H2O being reference standard.
Materials and Methods: A prospective, observational study was conducted in adult patients requiring positive pressure ventilation in the medical intensive care unit (ICU).
Two investigators independently assessed MOC and MLK twice on days 2 and 3 of intubation.
ICU registrar, unaware of earlier readings, noted manometric cuff-pressure within 5 min.
Inter-observer reliability was calculated using intraclass correlation coeffiient (ICC).
Validity of measurement was assessed using accepted reference standard of 20–30 cm H2O by manometer.
Results: Sixty patients between 17 and 82 years, on positive pressure ventilation were evaluated twice, by two investigators resulting in 240 observations.
Mean manometric pressures were 15.
7 + 2.
6 and 12.
2 + 2.
4 cm H2O using MOC and MLK techniques to maintain adequate ventilation.
ICC measured for reliability was high at 0.
69 and 0.
67 for MOC and MLK techniques.
Adequate ventilation was maintained in all patients and 57 of 60 (95%) were discharged alive without significant ventilatory complications.
Conclusions: Cuff pressures needed to maintain effective positive pressure ventilation was well below the accepted levels of 20–30 cm of H2O in majority patients.
MOC and MLK techniques have high reliability.
The result of the study has the implications on ICU ventilatory care.

Related Results

“ENDOTRACHEAL TUBE CUFF PRESSURE MONITORING USING PREFIXED VOLUME AIR VERSUS MANOMETER IN GENERAL ANAESTHESIA”
“ENDOTRACHEAL TUBE CUFF PRESSURE MONITORING USING PREFIXED VOLUME AIR VERSUS MANOMETER IN GENERAL ANAESTHESIA”
Background And Objective: The endotracheal tube (ETT) cuff seals the airway, preventing leakage and aspiration of pharyngeal contents into the trachea during ventilation. The Endot...
Endotracheal tube cuff pressure: need for precise measurement
Endotracheal tube cuff pressure: need for precise measurement
CONTEXT: High compliance endotracheal tubes cuffs are used to prevent gas leak and also pulmonary aspiration in mechanically ventilated patients. However, the use of the usual cuff...
Laboratory Model Study of Single Five-Spot and Single Injection Well Pilot Waterflooding
Laboratory Model Study of Single Five-Spot and Single Injection Well Pilot Waterflooding
Abstract Many full-scale waterflooding operations are preceded by pilot floods, one purpose of which is to provide an estimate of recoverable oil. A laboratory mo...
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Abstract Thoracic outlet syndrome (TOS) is a complex and often overlooked condition caused by the compression of neurovascular structures as they pass through the thoracic outlet. ...

Back to Top