Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Acute tricuspid valve annulus remodeling after transcatheter edge-to-edge repair with Triclip

View through CrossRef
Abstract Background Right ventricular (RV) adverse remodeling together with RV dysfunction, and not only tricuspid regurgitation (TR) severity, are independently associated with survival in patients with medically treated significant TR. Nevertheless, changes in RV dimensions and function after transcatheter tricuspid valve intervention and their association with outcomes remain largely unexplored, as well as tricuspid valve annulus (TVA) reverse remodeling. Aim of our study is to assess acute remodeling of TVA after tricuspid transcatheter edge-to-edge repair (T-TEER) with the TriClip device (Abbott Vascular, Santa Clara, CA, USA) using intraprocedural trans-esophageal echocardiography (TEE). Materials and methods This prospective, single-center study, conducted at Fondazione Policlinico Universitario Campus Bio-Medico of Rome, enrolled 60 consecutive symptomatic patients referred with the diagnosis of at least severe TR who underwent T-TEER from March 2021 to June 2024 with the TriClip System. Intraprocedural TEE was performed using Siemens Acuson SC2000 (Siemens Medical Systems, Pleasanton, CA, USA) at the beginning, and then using Philips EpiQ CVx (Philips Medical System, Andover, MA). A full-volume 3D echocardiographic data set was acquired during the procedure for each patient before and after the grasping. The following parameters were assessed using a multiplanar reconstruction analysis performed off-line using a 3D dataset: septal-lateral (SL) and antero-posterior (AP) annulus diameters; annulus area; annulus perimeter and eccentricity index. Results The mean age of the study cohort was 77,77 ± 6,18 years, and 77% were female. Twenty-eight patients (46,7%) had severe (3+), twenty-four patients (40%) massive (4+) and eight patients (13,3%) torrential (5+) tricuspid regurgitation. The majority of them had atrial functional tricuspid regurgitation, mostly due to annular dilatation. The acute procedural success was achieved in 82.22%. We observed an acute reduction in SL (from a median of 45 to 38 mm, p<0.0001), AP (from a median of 47.5 to 45.8 mm, p<0.0001), area (from a median of 18.4 to 16.2 cm2, p<0.0001), perimeter (from a median of 149 to 141 mm, p<0.0001) and eccentricity index (from 0.92 to 0.87, p <0.0001). The TV annulus was larger in patients with residual TR >2+. Analysis of the subgroups according to procedural success showed an acute inverse remodeling of the TV annulus independent of residual TR grade. We observed a significative reduction of TVA three-dimensional measurements immediately after the procedure. Conclusions In our study we observed that the reduction of TVA begins immediately after TriClip implantation, proving that T-TEER is effective in reducing TR and in inducing reverse remodeling of the TV apparatus. Concurrently, the baseline TV geometry influences the procedural results. Our data are gathered during T-TEER procedure, follow up data are needed for monitoring right ventricular performance. tva measures using mpr tr grade at baseline and after t-teer
Title: Acute tricuspid valve annulus remodeling after transcatheter edge-to-edge repair with Triclip
Description:
Abstract Background Right ventricular (RV) adverse remodeling together with RV dysfunction, and not only tricuspid regurgitation (TR) severity, are independently associated with survival in patients with medically treated significant TR.
Nevertheless, changes in RV dimensions and function after transcatheter tricuspid valve intervention and their association with outcomes remain largely unexplored, as well as tricuspid valve annulus (TVA) reverse remodeling.
Aim of our study is to assess acute remodeling of TVA after tricuspid transcatheter edge-to-edge repair (T-TEER) with the TriClip device (Abbott Vascular, Santa Clara, CA, USA) using intraprocedural trans-esophageal echocardiography (TEE).
Materials and methods This prospective, single-center study, conducted at Fondazione Policlinico Universitario Campus Bio-Medico of Rome, enrolled 60 consecutive symptomatic patients referred with the diagnosis of at least severe TR who underwent T-TEER from March 2021 to June 2024 with the TriClip System.
Intraprocedural TEE was performed using Siemens Acuson SC2000 (Siemens Medical Systems, Pleasanton, CA, USA) at the beginning, and then using Philips EpiQ CVx (Philips Medical System, Andover, MA).
A full-volume 3D echocardiographic data set was acquired during the procedure for each patient before and after the grasping.
The following parameters were assessed using a multiplanar reconstruction analysis performed off-line using a 3D dataset: septal-lateral (SL) and antero-posterior (AP) annulus diameters; annulus area; annulus perimeter and eccentricity index.
Results The mean age of the study cohort was 77,77 ± 6,18 years, and 77% were female.
Twenty-eight patients (46,7%) had severe (3+), twenty-four patients (40%) massive (4+) and eight patients (13,3%) torrential (5+) tricuspid regurgitation.
The majority of them had atrial functional tricuspid regurgitation, mostly due to annular dilatation.
The acute procedural success was achieved in 82.
22%.
We observed an acute reduction in SL (from a median of 45 to 38 mm, p<0.
0001), AP (from a median of 47.
5 to 45.
8 mm, p<0.
0001), area (from a median of 18.
4 to 16.
2 cm2, p<0.
0001), perimeter (from a median of 149 to 141 mm, p<0.
0001) and eccentricity index (from 0.
92 to 0.
87, p <0.
0001).
The TV annulus was larger in patients with residual TR >2+.
Analysis of the subgroups according to procedural success showed an acute inverse remodeling of the TV annulus independent of residual TR grade.
We observed a significative reduction of TVA three-dimensional measurements immediately after the procedure.
Conclusions In our study we observed that the reduction of TVA begins immediately after TriClip implantation, proving that T-TEER is effective in reducing TR and in inducing reverse remodeling of the TV apparatus.
Concurrently, the baseline TV geometry influences the procedural results.
Our data are gathered during T-TEER procedure, follow up data are needed for monitoring right ventricular performance.
tva measures using mpr tr grade at baseline and after t-teer.

Related Results

One-Year Outcomes of Screen Failures for Transcatheter Tricuspid Valve Repair: Insights From the TriSelect Study
One-Year Outcomes of Screen Failures for Transcatheter Tricuspid Valve Repair: Insights From the TriSelect Study
BACKGROUND: Observational registries have shown improved survival among patients with severe or greater tricuspid regurgitation (TR) undergoing transcatheter tr...
Concomitant tricuspid repair in mitral regurgitation surgery: a systematic review and meta-analysis
Concomitant tricuspid repair in mitral regurgitation surgery: a systematic review and meta-analysis
Abstract Background Tricuspid Regurgitation (TR) is common in patients with severe mitral disease. However, the evidence is insu...
When should the tricuspid valve be repaired during mitral valve repair?
When should the tricuspid valve be repaired during mitral valve repair?
Purpose of review Management of tricuspid regurgitation and annular dilation during mitral valve repair remains controversial. We review the latest evidence on indicati...
A Novel Transcatheter Edge-to-Edge Suturing Technique and Prototype for Repairing Tricuspid Valve Regurgitation
A Novel Transcatheter Edge-to-Edge Suturing Technique and Prototype for Repairing Tricuspid Valve Regurgitation
Abstract Tricuspid valve regurgitation is a major clinical issue that continues to attract interest from interventional cardiologists and medical device designers du...
Acute Impact of Transcatheter Edge‐to‐Edge Repair of Tricuspid Regurgitation on Right Ventricular Hemodynamics
Acute Impact of Transcatheter Edge‐to‐Edge Repair of Tricuspid Regurgitation on Right Ventricular Hemodynamics
Background Tricuspid transcatheter edge‐to‐edge repair is an established therapy for high‐grade tricuspid regurgitation, but its acute impact on right ventricul...

Back to Top