Rapid Assessment of Relative Hemolysis Amidst Input Uncertainties in Laminar Flow
View through CrossRef
Predicting absolute values of hemolysis using the power-law model to guide medical device design is hampered by uncertainties stemming from four sources of model inputs: incoming/upstream velocity profiles, blood viscosity model, power law hemolysis coefficients, and obtaining accurate stress exposure times. Amidst all these uncertainties, enabling rapid assessments and predictions of relative hemolysis would still be valuable towards evaluating device design prototypes. Towards achieving this objective, hemolysis data from Eulerian modeling framework was first generated from computational fluid dynamic simulations encompassing: five blood viscosity models, four sets of hemolysis power law coefficients, fully developed as well as developing velocity flow conditions, wide range of shear stresses (1 – 600 Pa), strain rates (1 – 10,000 s-1) and stress exposure times (5 – 400 milliseconds). Corresponding hemolysis predictions were also made in a Lagrangian framework via numerical integration of shear stress and residence time spatial variations under the assumption of fully developed Newtonian fluid flow. Absolute hemolysis predictions (from both frameworks) were proportional to each other and independent of the blood viscosity model. Further, relative hemolysis trends were not dependent on the hemolysis power law coefficients. However, accuracy in wall shear stresses in developing flow conditions are necessary for accurate relative hemolysis assessments.
Title: Rapid Assessment of Relative Hemolysis Amidst Input Uncertainties in Laminar Flow
Description:
Predicting absolute values of hemolysis using the power-law model to guide medical device design is hampered by uncertainties stemming from four sources of model inputs: incoming/upstream velocity profiles, blood viscosity model, power law hemolysis coefficients, and obtaining accurate stress exposure times.
Amidst all these uncertainties, enabling rapid assessments and predictions of relative hemolysis would still be valuable towards evaluating device design prototypes.
Towards achieving this objective, hemolysis data from Eulerian modeling framework was first generated from computational fluid dynamic simulations encompassing: five blood viscosity models, four sets of hemolysis power law coefficients, fully developed as well as developing velocity flow conditions, wide range of shear stresses (1 – 600 Pa), strain rates (1 – 10,000 s-1) and stress exposure times (5 – 400 milliseconds).
Corresponding hemolysis predictions were also made in a Lagrangian framework via numerical integration of shear stress and residence time spatial variations under the assumption of fully developed Newtonian fluid flow.
Absolute hemolysis predictions (from both frameworks) were proportional to each other and independent of the blood viscosity model.
Further, relative hemolysis trends were not dependent on the hemolysis power law coefficients.
However, accuracy in wall shear stresses in developing flow conditions are necessary for accurate relative hemolysis assessments.
Related Results
A-345 Effect of Hemolysis on Routine Blood Gas Analytes
A-345 Effect of Hemolysis on Routine Blood Gas Analytes
Abstract
Background
Hemolysis is a major pre-analytical concern for most laboratory analytes. Detection of hemolysis and mitigat...
Isolation And Characterization Of Biosurfactant Producing Bacteria From Different Environmental Soil Samples
Isolation And Characterization Of Biosurfactant Producing Bacteria From Different Environmental Soil Samples
Biosurfactants are natural substances produced by several bacterial and fungal organisms that are amphiphilic and are extracellular (a part of the cell membrane). Biosurfactants ca...
Ghost cells as a two-phase blood analog fluid —fluorescent mechanical hemolysis detection
Ghost cells as a two-phase blood analog fluid —fluorescent mechanical hemolysis detection
Abstract
Background
This study investigated fluorescent hemolysis detection as an optical method to detect local hemolysis in mechanical circulatory support systems, addres...
Three in One: Systemic Lupus Erythematosus, HELLP Syndrome, and Antiphospholipid Syndrome: A Case Report and Literature Review
Three in One: Systemic Lupus Erythematosus, HELLP Syndrome, and Antiphospholipid Syndrome: A Case Report and Literature Review
Abstract
Introduction
Systemic lupus erythematosus (SLE) is a multisystem autoimmune disease commonly affecting women of reproductive age. Its overlap with HELLP syndrome (Hemolysi...
Association between inflammatory and hemolysis markers in children with sickle cell disease
Association between inflammatory and hemolysis markers in children with sickle cell disease
Abstract
Background: Sickle cell disease (SCD) is a severe hemoglobin disorder characterized by recurrent vaso-occlusive...
Red cell serological characterization of autoimmune hemolytic anemia in systemic lupus erythematosus patients
Red cell serological characterization of autoimmune hemolytic anemia in systemic lupus erythematosus patients
Abstract:
INTRODUCTION:
Autoimmune hemolytic anemia (AIHA) is a clinical condition with increased red cell destruction or decreased red cell surv...
Hemolysis and Renal Dysfunction in Hemodialysis A Bilirubin-Based Study with Hepatic Confounding
Hemolysis and Renal Dysfunction in Hemodialysis A Bilirubin-Based Study with Hepatic Confounding
Abstract
Background:
Hemolysis is a common complication in patients with renal failure undergoing hemodialysis, resulting from ...
Hemolysis of red blood cells during processing and storage
Hemolysis of red blood cells during processing and storage
BACKGROUND: During processing and storage, red blood cells (RBCs) undergo changes and cell injury resulting in hemolysis. Mostly, the separation of whole blood in top‐and‐bottom qu...