Seismic Response of Reinforced-Concrete One-Storey Precast Industrial Buildings with Horizontal Cladding Panels

View through CrossRef
An extensive parametric study of the seismic response of one-storey precast buildings with horizontal cladding panels frequently used in Central Europe was conducted to analyse the panels’ influence on the overall response of buildings and to find out if the panels can be considered non-structural elements when they are attached to the main building with the connections typically used in practice in Central Europe. The studied structural system consisted of reinforced concrete columns and beams connected by dowels. Horizontal cladding panels were attached to columns using one of the most frequently used isostatic fastening systems. The top connections provided out-of-plane stability, and the bottom connections supported the panel in the vertical direction. The parametric study was preceded by extensive experimental research, including cyclic tests on connections and full-scale shaking table tests of whole buildings. The results of experiments were used to reveal the basic response mechanisms of panels and connections and to develop, validate and calibrate numerical models employed in the parametric study presented herein. Fifteen generalised structures with different masses and heights were subjected to 30 accelerograms with two peak ground acceleration (PGA) intensities of 0.3 g and 0.5 g, corresponding to significant damage and near-collapse limit states. The effects of the construction imperfections in connections, the silicon sealant panel-to-panel connections and different types of connections of the bottom panel to the foundation were analysed. The crucial parameter influencing the response was the displacement capacity of the connections, which was considerably affected by the construction imperfections and, consequently, difficult to estimate. It has been observed that in some buildings, particularly in shorter structures with smaller mass, cladding panels can have a somewhat more notable influence on the overall response. However, in general, when the considered types of connections are used, the panels can be considered as non-structural elements, which do not importantly influence the response of the main building. Owing to structural imperfections and relatively short available gaps, the failure of the considered top connections and falling of the panels is very likely in the high seismicity regions. In the most adverse cases, it can occur even in the moderate seismicity regions.
Title: Seismic Response of Reinforced-Concrete One-Storey Precast Industrial Buildings with Horizontal Cladding Panels
Description:
An extensive parametric study of the seismic response of one-storey precast buildings with horizontal cladding panels frequently used in Central Europe was conducted to analyse the panels’ influence on the overall response of buildings and to find out if the panels can be considered non-structural elements when they are attached to the main building with the connections typically used in practice in Central Europe.
The studied structural system consisted of reinforced concrete columns and beams connected by dowels.
Horizontal cladding panels were attached to columns using one of the most frequently used isostatic fastening systems.
The top connections provided out-of-plane stability, and the bottom connections supported the panel in the vertical direction.
The parametric study was preceded by extensive experimental research, including cyclic tests on connections and full-scale shaking table tests of whole buildings.
The results of experiments were used to reveal the basic response mechanisms of panels and connections and to develop, validate and calibrate numerical models employed in the parametric study presented herein.
Fifteen generalised structures with different masses and heights were subjected to 30 accelerograms with two peak ground acceleration (PGA) intensities of 0.
3 g and 0.
5 g, corresponding to significant damage and near-collapse limit states.
The effects of the construction imperfections in connections, the silicon sealant panel-to-panel connections and different types of connections of the bottom panel to the foundation were analysed.
The crucial parameter influencing the response was the displacement capacity of the connections, which was considerably affected by the construction imperfections and, consequently, difficult to estimate.
It has been observed that in some buildings, particularly in shorter structures with smaller mass, cladding panels can have a somewhat more notable influence on the overall response.
However, in general, when the considered types of connections are used, the panels can be considered as non-structural elements, which do not importantly influence the response of the main building.
Owing to structural imperfections and relatively short available gaps, the failure of the considered top connections and falling of the panels is very likely in the high seismicity regions.
In the most adverse cases, it can occur even in the moderate seismicity regions.

Related Results

Optimum Location of Soft Storey in Multi-Storeyed Building
Optimum Location of Soft Storey in Multi-Storeyed Building
The present study is focus on 11-storey reinforced concrete buildings to optimize the location of soft storey under seismic zone-v. The plan of building 40m x 40m is considered. In...
CALCULATION OF THE STRESS-STRAIN STATE OF THE CLADDING LAYER DURING CLADDING (WELDING) BY EXPLOSION
CALCULATION OF THE STRESS-STRAIN STATE OF THE CLADDING LAYER DURING CLADDING (WELDING) BY EXPLOSION
Purpose. Development of a mathematical model of the process of elastoplastic deformation of the cladding layer of a layered workpiece during welding (cladding) by explosion with th...
Seismic Behavior of Mid-Rise Precast Reinforced Concrete Building with Effect of Joints and Supports
Seismic Behavior of Mid-Rise Precast Reinforced Concrete Building with Effect of Joints and Supports
Precast concrete structures are widely used in construction. It consists of prefabricated elements casted in industry and connected to each other to form a homogeneous structure. C...
Research progress on effect of laser cladding process on metal surface properties: a review
Research progress on effect of laser cladding process on metal surface properties: a review
Abstract Laser cladding has been widely used in surface modification, material repair, and additive manufacturing due to its high precision, high efficiency, and ...
Effects of Ni-Ti Content on Mechanical Properties of Laser Cladding A100-(Ni-Ti) Coatings
Effects of Ni-Ti Content on Mechanical Properties of Laser Cladding A100-(Ni-Ti) Coatings
Among many methods to enhance the crack resistance of laser cladding coatings, adjusting the composition of laser cladding material is the most simple, feasible, and effective meth...
He found use for reinforced concrete where, it would seem, this material has no place
He found use for reinforced concrete where, it would seem, this material has no place
Introduction. The article is devoted to an employee of the Research Institute of Reinforced Concrete, Doctor of Technical Sciences, Professor I.G. Ludkovsky, a specialist in the fi...
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Reinforced masonry constitutes about 10% of all low-rise construction in the US. Most of these structures are commercial and school buildings. It may also be used for multi-story h...
Laser Cladded Surface Hardening Coating With Gradient of Mechanical Properties
Laser Cladded Surface Hardening Coating With Gradient of Mechanical Properties
The present dissertation “Laser Cladded Surface Hardening Coating with Gradient of Mechanical Properties” is devoted to the research of laser cladding process for obtaining high qu...