Javascript must be enabled to continue!
Enhancing Rigless Intervention Efficiency in Bi-Lateral Oil Producer Through Coiled Tubing Optical Telemetry, Multilateral Tool, and Single-Phase Retarded Inorganic Acid: A Case Study from South Kuwait
View through CrossRef
Abstract
Developments in horizontal drilling and completion techniques have enabled drilling an increasing number of wells. In the pursuit of cost optimization and enhanced recovery through maximized reservoir contact, operators are placing special interest on multilateral completions. However, multilateral wells add complexity to rigless intervention and production enhancement work as those activities are heavily dependent on lateral accessibility.
An advanced rigless intervention in a multilateral well relied on coiled tubing (CT) equipped with optical fiber and real-time downhole measurements and a multilateral entry tool (MLT). Downhole readings included casing collar locator (CCL), gamma ray, CT internal pressure, annulus pressure, annulus temperature, and axial force. Optical telemetry was used for lateral identification and for optimal actuation of the orienting and bent sub-components of the MLT while profiling and accessing the lateral. Throughout the stimulation treatment, optical telemetry was instrumental to understanding changing downhole conditions and keeping injection rates below fracturing pressure.
The candidate well was a carbonate bi-lateral oil producer completed through 6 1/8-in. uncased horizontal sections. Both laterals exhibited average length of 2,400 ft, and the reservoir featured a bottomhole temperature near 140°F and bottomhole pressure close to 3,050 psi. Because of real-time optical telemetry, profiling of the lateral was completed in less than 3 hours, which represents 50% reduction of the average profiling time in similar wells. Both laterals were stimulated via CT with a total of 4,000 bbl of single-phase retarded inorganic acid system (SPRIAS), which enables carbonate stimulation with better wormholing performance than emulsified acid while eliminating its drawbacks, such as high CT friction pressure and potential emulsion issues. In comparison with emulsified acid, the pumping time with SPRIAS was 35% lower, bringing additional efficiency to the intervention. The ability to make fast, informed decisions based on optical telemetry was the cornerstone of this intervention approach.
This paper documents a value case study for CT rigless intervention in South Kuwait, where the combination of an array of technologies, such as CT optical telemetry, MLT, and SPRIAS, enhanced rigless intervention efficiency, reducing total operation time by 30%, when compared to conventional CT stimulation approach in multilateral wells.
Title: Enhancing Rigless Intervention Efficiency in Bi-Lateral Oil Producer Through Coiled Tubing Optical Telemetry, Multilateral Tool, and Single-Phase Retarded Inorganic Acid: A Case Study from South Kuwait
Description:
Abstract
Developments in horizontal drilling and completion techniques have enabled drilling an increasing number of wells.
In the pursuit of cost optimization and enhanced recovery through maximized reservoir contact, operators are placing special interest on multilateral completions.
However, multilateral wells add complexity to rigless intervention and production enhancement work as those activities are heavily dependent on lateral accessibility.
An advanced rigless intervention in a multilateral well relied on coiled tubing (CT) equipped with optical fiber and real-time downhole measurements and a multilateral entry tool (MLT).
Downhole readings included casing collar locator (CCL), gamma ray, CT internal pressure, annulus pressure, annulus temperature, and axial force.
Optical telemetry was used for lateral identification and for optimal actuation of the orienting and bent sub-components of the MLT while profiling and accessing the lateral.
Throughout the stimulation treatment, optical telemetry was instrumental to understanding changing downhole conditions and keeping injection rates below fracturing pressure.
The candidate well was a carbonate bi-lateral oil producer completed through 6 1/8-in.
uncased horizontal sections.
Both laterals exhibited average length of 2,400 ft, and the reservoir featured a bottomhole temperature near 140°F and bottomhole pressure close to 3,050 psi.
Because of real-time optical telemetry, profiling of the lateral was completed in less than 3 hours, which represents 50% reduction of the average profiling time in similar wells.
Both laterals were stimulated via CT with a total of 4,000 bbl of single-phase retarded inorganic acid system (SPRIAS), which enables carbonate stimulation with better wormholing performance than emulsified acid while eliminating its drawbacks, such as high CT friction pressure and potential emulsion issues.
In comparison with emulsified acid, the pumping time with SPRIAS was 35% lower, bringing additional efficiency to the intervention.
The ability to make fast, informed decisions based on optical telemetry was the cornerstone of this intervention approach.
This paper documents a value case study for CT rigless intervention in South Kuwait, where the combination of an array of technologies, such as CT optical telemetry, MLT, and SPRIAS, enhanced rigless intervention efficiency, reducing total operation time by 30%, when compared to conventional CT stimulation approach in multilateral wells.
Related Results
Offshore Rigless Coiled Tubing Operations Drives a Paradigm Shift of Cost-Effective Interventions in Gulf of Suez, Egypt
Offshore Rigless Coiled Tubing Operations Drives a Paradigm Shift of Cost-Effective Interventions in Gulf of Suez, Egypt
Abstract
Gulf of Suez is one of the prolific Oil & gas areas in the world. Oil Production in this area started as early as 1960s when Giant Morgan Field was disc...
Rigless Well Intervention Using Tubing Patch Technology Helps Restore Inactive Wells
Rigless Well Intervention Using Tubing Patch Technology Helps Restore Inactive Wells
Abstract
This paper provides in-depth analysis of a low-cost solution to economically sustain production and avoid high workover costs. This paper conducts the techn...
Prebending Coiled Tubing and Its Fatigue Life Prediction
Prebending Coiled Tubing and Its Fatigue Life Prediction
Coiled tubing is widely used in oil drilling and production operations. However, extreme high stress variation of coiled tubing during the processes of pulling out, rolling in the ...
Abstract 173: Simple Guidance Improves Appropriate Telemetry Utilization
Abstract 173: Simple Guidance Improves Appropriate Telemetry Utilization
Introduction:
Cardiac telemetry is an in-hospital monitoring tool intended for ischemia surveillance, monitor QT-interval prolongation, and detect arrhythmias. It is a ...
Innovative Coiled Tubing Technology to Improve Performance in Horizontal Completions
Innovative Coiled Tubing Technology to Improve Performance in Horizontal Completions
Abstract
Recent technological innovations in seismic imaging, directional drilling and hydraulic fracturing and other completion techniques have made development of ...
Metal-Polymer Coiled Tubing
Metal-Polymer Coiled Tubing
Abstract
Metal-polymer coiled tubing (MCT) are flexible pipes based on a copolymer reinforced with steel tape, wires and ropes. During the research was proposed and ...
Improving Efficiency of Coiled Tubing Operations on Vankor Field
Improving Efficiency of Coiled Tubing Operations on Vankor Field
Abstract
Coiled tubing is commonly used as an intervention tool for treatment delivery in long horizontal wells. As with any intervention tool, however, coiled tubin...
Production Optimization in Bonga Deepwater Through Rigless Intervention
Production Optimization in Bonga Deepwater Through Rigless Intervention
Abstract
Maximizing oil recovery and production remains paramount in Deepwater operations. This paper focuses on enhanced oil recovery and production optimization in...

