Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Experimental Investigation of Performance Enhancement of a Vapor Compression Refrigeration System by Vortex Tube Cooling

View through CrossRef
This study aimed to analyze the difference in operation of the vapor compression refrigeration (VCR) system with vortex tube cooling. By using varied loads, experiments were conducted on the evaporator section of a vapor compression refrigeration system. In an attempt to improve the use of subcooling for the refrigeration, the effect of subcooling of refrigerant by vortex tube cooling was likewise examined. The test conditions included various loads (25%, 50%, 75% and 100%) and cold mass fractions (25%, 50% and 75%). This research described coefficient of performance (COP) as one of the significant parameters, in addition to heat rejection and refrigerating effect. The ideal efficiency appeared to be with the cold mass fraction of 25% and load of 100%, as identified by the results. Consequently, the COP could be enhanced by 5.16% along with an approximately 4.36% decline in average power use. Improved guidelines for vapor compression refrigeration systems to enhance the operation of the system are an expected benefit of this study.
Title: Experimental Investigation of Performance Enhancement of a Vapor Compression Refrigeration System by Vortex Tube Cooling
Description:
This study aimed to analyze the difference in operation of the vapor compression refrigeration (VCR) system with vortex tube cooling.
By using varied loads, experiments were conducted on the evaporator section of a vapor compression refrigeration system.
In an attempt to improve the use of subcooling for the refrigeration, the effect of subcooling of refrigerant by vortex tube cooling was likewise examined.
The test conditions included various loads (25%, 50%, 75% and 100%) and cold mass fractions (25%, 50% and 75%).
This research described coefficient of performance (COP) as one of the significant parameters, in addition to heat rejection and refrigerating effect.
The ideal efficiency appeared to be with the cold mass fraction of 25% and load of 100%, as identified by the results.
Consequently, the COP could be enhanced by 5.
16% along with an approximately 4.
36% decline in average power use.
Improved guidelines for vapor compression refrigeration systems to enhance the operation of the system are an expected benefit of this study.

Related Results

Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Stability and dynamics of geophysical neutral vortices
Stability and dynamics of geophysical neutral vortices
(English) Mesoscale and submesoscale vortical structures are ubiquitous in the ocean and atmosphere. Most of these vortices are long-lived with a lifetime of several months. They o...
Investigation of vortex in pump sump by V3V measurements
Investigation of vortex in pump sump by V3V measurements
Abstract The aims, scope and conclusions of the paper must be in a self-contained abstract of a single paragraph with 60-120 words. The abstract must be informative ...
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
[RETRACTED] Gro-X Male Enhancement | Safely Grow Your Size, Sex Drive v1
[RETRACTED] Gro-X Male Enhancement | Safely Grow Your Size, Sex Drive v1
[RETRACTED]Gro-X Male Enhancement Reviews - Is It Worth the Money? Scam or Legit? Gro-X Male Enhancement Male health is very important, especially for a couple. Low sperm count an...
The Miniaturization of a Refrigeration Vapor Compression System and Application to the Cooling of High Power Microelectronics
The Miniaturization of a Refrigeration Vapor Compression System and Application to the Cooling of High Power Microelectronics
The study develops an analytical model of an optimized small scale refrigeration system using ejector vapor compression, with application to the cooling of the electronic component...
[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED]Rhino XL Reviews, NY USA: Studies show that testosterone levels in males decrease constantly with growing age. There are also many other problems that males face due ...
Refrigeration
Refrigeration
Abstract This chapter focuses primarily on refrigeration applications, which cover such diverse uses as food processing and storage, supermarket display cases, skating ri...

Back to Top