Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

An evaluation of the Periotest® method as a tool for monitoring tooth mobility in dental traumatology

View through CrossRef
Abstract –  Background/aim:  The Periotest® method is a technique for the objective assessment of tooth mobility. The aims of this study were to determine normal Periotest® values in the vertical and horizontal dimensions of periodontally healthy teeth in individuals aged 20–35 years and investigate the reliability of Periotest® in terms of intra‐series and inter‐series reproducibility before and after applying a dental trauma splint in vivo.Materials and methods:  Periotest® values were measured in periodontally healthy dental students (n = 33; mean age 24.7 years) at reproducible measuring points in the vertical and horizontal dimensions, before and after splint insertion. Three readings were taken per series to observe the intra‐series reproducibility; three series were measured to test inter‐series reproducibility (Friedman‐test; P ≤ 0.001). Two different wire‐composite splints, 0.45 mm Dentaflex and 0.8 × 1.8 Strengtheners, were inserted and the Periotest® values were measured.Results:  The median Periotest® values before splinting were: canines ‐2.5, lateral incisors ‐0.9, and central incisors 0.0 for the vertical dimension, and canines 1.1, lateral incisors 3.2, and central incisors 3.6 for the horizontal dimension. The intra‐series and inter‐series Periotest® values were highly reproducible.Conclusion:  The Periotest® method provides highly reproducible results. Focused on dental trauma, the method can be applied diagnostically during the splint and follow‐up period and for evaluating splint rigidity.
Title: An evaluation of the Periotest® method as a tool for monitoring tooth mobility in dental traumatology
Description:
Abstract –  Background/aim:  The Periotest® method is a technique for the objective assessment of tooth mobility.
The aims of this study were to determine normal Periotest® values in the vertical and horizontal dimensions of periodontally healthy teeth in individuals aged 20–35 years and investigate the reliability of Periotest® in terms of intra‐series and inter‐series reproducibility before and after applying a dental trauma splint in vivo.
Materials and methods:  Periotest® values were measured in periodontally healthy dental students (n = 33; mean age 24.
7 years) at reproducible measuring points in the vertical and horizontal dimensions, before and after splint insertion.
Three readings were taken per series to observe the intra‐series reproducibility; three series were measured to test inter‐series reproducibility (Friedman‐test; P ≤ 0.
001).
Two different wire‐composite splints, 0.
45 mm Dentaflex and 0.
8 × 1.
8 Strengtheners, were inserted and the Periotest® values were measured.
Results:  The median Periotest® values before splinting were: canines ‐2.
5, lateral incisors ‐0.
9, and central incisors 0.
0 for the vertical dimension, and canines 1.
1, lateral incisors 3.
2, and central incisors 3.
6 for the horizontal dimension.
The intra‐series and inter‐series Periotest® values were highly reproducible.
Conclusion:  The Periotest® method provides highly reproducible results.
Focused on dental trauma, the method can be applied diagnostically during the splint and follow‐up period and for evaluating splint rigidity.

Related Results

Management of Oblique Root Fracture Using Mineral Trioxide Aggregate: A Case Report
Management of Oblique Root Fracture Using Mineral Trioxide Aggregate: A Case Report
Root fractures are relatively uncommon compared to other types of dental traumas. It is sometimes extremely difficult for practitioners to decide what should be done and which appr...
Awareness of Dental Personnel towards Occupational Injury- A Cross Sectional Study
Awareness of Dental Personnel towards Occupational Injury- A Cross Sectional Study
TITLE: Awareness of dental personnel towards occupational injury- a cross sectional study ABSTRACT Objective: To determine the awareness of dental personnel towards dental occup...
To Evaluate the Reliability of Periotest Device In Assessment Of Implant Stability
To Evaluate the Reliability of Periotest Device In Assessment Of Implant Stability
Background and Aim: Osseointegration has been defined as a direct structural and functional connection between ordered living bone and the surface of a load- carrying implant. Auth...
Guest Editorial
Guest Editorial
Dental caries is one of the major health problems in Indonesia. Data from Indonesian Basic Health Research in 2013, 2015 and 2018 showed a consistent increase in the prevalence of ...
Comparison of prevalence of symptoms of carpal tunnel syndrome between dental students and dental practitioners - A cross-sectional study
Comparison of prevalence of symptoms of carpal tunnel syndrome between dental students and dental practitioners - A cross-sectional study
Background: carpal tunnel syndrome (CTS) arises from compression of the median nerve when it passes through the carpal tunnel in the wrist. Dental professionals use vibratory instr...
A new CAD/CAM tooth mobility simulating model for dental in vitro investigations
A new CAD/CAM tooth mobility simulating model for dental in vitro investigations
Abstract Objectives To validate a new tooth mobility simulating in vitro model for biomechanical tests of dental appliances and restorations. ...
Optimising tool wear and workpiece condition monitoring via cyber-physical systems for smart manufacturing
Optimising tool wear and workpiece condition monitoring via cyber-physical systems for smart manufacturing
Smart manufacturing has been developed since the introduction of Industry 4.0. It consists of resource sharing and networking, predictive engineering, and material and data analyti...

Back to Top