Javascript must be enabled to continue!
Fault Protection Considerations for MVDC Shipboard Power Systems Operating with Pulsed-Power Loads
View through CrossRef
Medium Voltage Direct Current (MVDC) power distribution architectures are of immense interest for various shipboard power applications due to their advantages over classical MVAC distribution systems with respect to power quality, power density, and efficiency. However, MVDC are far away from maturity when compared to MVAC with respect to fault detection and isolation. Currently, there are no standards available for applying MVDC protection systems in shipboard applications. Furthermore, due to the absence of zero crossings in DC waveforms and unique transient fault signatures, it is challenging to design effective protection system schemes to isolate faults via conventional protection systems. This paper investigates and analyses various types of shipboard MVDC dynamic fault behaviours and signatures under different DC bus disturbances such as: bus to ground, bus to bus to ground, and impact of Pulsed-Power Load (PPL) with and without faults on a shipboard MVDC distribution system. Furthermore, a communication-based fault detection and isolation system controller that improves upon a directional ac overcurrent relay protection system is proposed offering additional protection discrimination between faults and PPLs in MVDC systems. To validate the effectiveness of the proposed protection controller, different bus current disturbances are simulated within a time-domain electromagnetic transient simulation of a shipboard power system including a PPL system operating with different ramp rate profiles, pulse widths, peak powers, and fault locations
World Scientific and Engineering Academy and Society (WSEAS)
Title: Fault Protection Considerations for MVDC Shipboard Power Systems Operating with Pulsed-Power Loads
Description:
Medium Voltage Direct Current (MVDC) power distribution architectures are of immense interest for various shipboard power applications due to their advantages over classical MVAC distribution systems with respect to power quality, power density, and efficiency.
However, MVDC are far away from maturity when compared to MVAC with respect to fault detection and isolation.
Currently, there are no standards available for applying MVDC protection systems in shipboard applications.
Furthermore, due to the absence of zero crossings in DC waveforms and unique transient fault signatures, it is challenging to design effective protection system schemes to isolate faults via conventional protection systems.
This paper investigates and analyses various types of shipboard MVDC dynamic fault behaviours and signatures under different DC bus disturbances such as: bus to ground, bus to bus to ground, and impact of Pulsed-Power Load (PPL) with and without faults on a shipboard MVDC distribution system.
Furthermore, a communication-based fault detection and isolation system controller that improves upon a directional ac overcurrent relay protection system is proposed offering additional protection discrimination between faults and PPLs in MVDC systems.
To validate the effectiveness of the proposed protection controller, different bus current disturbances are simulated within a time-domain electromagnetic transient simulation of a shipboard power system including a PPL system operating with different ramp rate profiles, pulse widths, peak powers, and fault locations.
Related Results
Integration Techniques of Fault Detection and Isolation Using Interval Observers
Integration Techniques of Fault Detection and Isolation Using Interval Observers
An interval observer has been illustrated to be a suitable approach to detect and isolate faults affecting complex dynamical industrial systems.
Concerning fault detection, interv...
Deformational Processes Accommodating Slip on an Active Low-Angle Normal Fault, Suckling-Dayman Metamorphic Core Complex, Papua New Guinea
Deformational Processes Accommodating Slip on an Active Low-Angle Normal Fault, Suckling-Dayman Metamorphic Core Complex, Papua New Guinea
<p><b>Detachment faults that can be shown to have slipped at dips <30° in highly extended continental crust are referred to as “Low-Angle Normal Faults” (LANFs). The...
Decomposition and Evolution of Intracontinental Strike‐Slip Faults in Eastern Tibetan Plateau
Decomposition and Evolution of Intracontinental Strike‐Slip Faults in Eastern Tibetan Plateau
Abstract:Little attention had been paid to the intracontinental strike‐slip faults of the Tibetan Plateau. Since the discovery of the Longriba fault using re‐measured GPS data in 2...
Normal Fault Transmissibility Characteristics Under the Transition Condition of Fault Conduction and Sealing Observed in Simulation Experiments
Normal Fault Transmissibility Characteristics Under the Transition Condition of Fault Conduction and Sealing Observed in Simulation Experiments
In rift basins, normal fault conducting and sealing fluids are the main mechanisms for evaluating fault-related reservoirs, and the defined threshold value of fault conduction or s...
Innovative Energy Management System for MVDC Networks with Black-Start Capabilities
Innovative Energy Management System for MVDC Networks with Black-Start Capabilities
Medium voltage DC (MVDC) networks are attracting more attention amid increased renewables penetration. The reliability of these DC systems is critical, especially following grid co...
Chapter 4: Displacement on the southern San Andreas fault
Chapter 4: Displacement on the southern San Andreas fault
The pre-Quaternary geology of the southern Chocolate and Cargo Muchacho mountains correlates with that exposed in San Gorgonio Pass between the Mission Creek and Banning branches o...
Late Quaternary Activity: Kouma Fault
Late Quaternary Activity: Kouma Fault
The Kouma Fault, located at the northern foot of the Mangshan Mountain in Luoyang City, Henan Province, China, is an active fault newly discovered in the field seismic geological s...
Modelling and control of a VSC medium‐voltage DC distribution network with DFIG wind farm
Modelling and control of a VSC medium‐voltage DC distribution network with DFIG wind farm
The voltage source converters (VSC) medium‐voltage DC (MVDC) is the future distribution network for integrating renewable energy sources. The doubly fed induction generator (DFIG) ...