On electromagnetic head-surface digitization in MEG and EEG
View through CrossRef
Abstract
In magnetoencephalographic (MEG) and electroencephalographic (EEG) studies, the accuracy of the head digitization impacts the co-registration between MEG/EEG and structural magnetic resonance imaging (MRI) data. The co-registration accuracy in turn affects the spatial accuracy in neural source imaging. Precisely digitized head-surface (scalp) points do not only improve the co-registration but can also be used to deform a template MRI to create an individualized-template MRI that can be used for conductivity modeling in MEG/EEG source imaging if the individual’s structural MRI is unavailable. Although optical scanners have been introduced for digitization, especially for dense EEG electrode sets, electromagnetic tracking (EMT) systems (particularly Fastrak®, Polhemus Inc., Colchester, VT, USA) have been the most often applied solution for digitization in MEG and EEG acquisition. EMT systems may occasionally suffer from ambient electromagnetic interference which makes it challenging to achieve (sub-)millimeter digitization accuracy. The current study i) evaluated the performance of the Fastrak® EMT system under different conditions in MEG/EEG digitization, and ii) explores the usability of two alternative EMT systems (Aurora®, NDI, Waterloo, ON, Canada; Fastrak® with a short-range transmitter) for digitization. Tracking fluctuation, digitization accuracy, and robustness of the systems were evaluated in several test cases using test frames and human head models. The digitization performance of the two alternative systems was compared against the Fastrak® system. The results showed that the Fastrak® system is accurate and robust for MEG/EEG digitization if the recommended operating conditions are met. The Fastrak® with the short-range transmitter shows comparatively higher digitization error if digitization is not carried out very close to the transmitter. The study also evinces that the Aurora® system can be used for MEG/EEG digitization. Its real-time error estimation feature can potentially improve digitization accuracy, albeit some modifications would be required to make the system a practical and easy-to-use digitizer.
Title: On electromagnetic head-surface digitization in MEG and EEG
Description:
Abstract
In magnetoencephalographic (MEG) and electroencephalographic (EEG) studies, the accuracy of the head digitization impacts the co-registration between MEG/EEG and structural magnetic resonance imaging (MRI) data.
The co-registration accuracy in turn affects the spatial accuracy in neural source imaging.
Precisely digitized head-surface (scalp) points do not only improve the co-registration but can also be used to deform a template MRI to create an individualized-template MRI that can be used for conductivity modeling in MEG/EEG source imaging if the individual’s structural MRI is unavailable.
Although optical scanners have been introduced for digitization, especially for dense EEG electrode sets, electromagnetic tracking (EMT) systems (particularly Fastrak®, Polhemus Inc.
, Colchester, VT, USA) have been the most often applied solution for digitization in MEG and EEG acquisition.
EMT systems may occasionally suffer from ambient electromagnetic interference which makes it challenging to achieve (sub-)millimeter digitization accuracy.
The current study i) evaluated the performance of the Fastrak® EMT system under different conditions in MEG/EEG digitization, and ii) explores the usability of two alternative EMT systems (Aurora®, NDI, Waterloo, ON, Canada; Fastrak® with a short-range transmitter) for digitization.
Tracking fluctuation, digitization accuracy, and robustness of the systems were evaluated in several test cases using test frames and human head models.
The digitization performance of the two alternative systems was compared against the Fastrak® system.
The results showed that the Fastrak® system is accurate and robust for MEG/EEG digitization if the recommended operating conditions are met.
The Fastrak® with the short-range transmitter shows comparatively higher digitization error if digitization is not carried out very close to the transmitter.
The study also evinces that the Aurora® system can be used for MEG/EEG digitization.
Its real-time error estimation feature can potentially improve digitization accuracy, albeit some modifications would be required to make the system a practical and easy-to-use digitizer.
Related Results
Event-Wise Stability of Patient-Specific EEG-MEG Deep Learning Spike Detection in Clinical MEG
Event-Wise Stability of Patient-Specific EEG-MEG Deep Learning Spike Detection in Clinical MEG
Abstract
Objective
Computational magnetoencephalography (MEG) interictal epileptiform discharge (IED) detectors have mainly use...
Emergence of synchronous EEG spindles from asynchronous MEG spindles
Emergence of synchronous EEG spindles from asynchronous MEG spindles
AbstractSleep spindles are bursts of rhythmic 10–15 Hz activity, lasting ∼0.5–2 s, that occur during Stage 2 sleep. They are coherent across multiple cortical and thalamic location...
Platform Session B: Clinical Neurophysiology/Clinical Epilepsy
3:00 p.m.–6:00 p.m.
Platform Session B: Clinical Neurophysiology/Clinical Epilepsy
3:00 p.m.–6:00 p.m.
1
Jose F.
Tellez‐Zenteno,
1
Scott B.
Patten, and
1
Samuel
Wiebe
...
THE EFFECT OF PETHIDINE ON THE NEONATAL EEG
THE EFFECT OF PETHIDINE ON THE NEONATAL EEG
SUMMARYThirty‐two preterm infants were monitored with an on‐line cotside EEG system for periods of up to nine days. Changes in the normal pattern of discontinuity of the EEG were s...
Pharmaco-EEG Studies in Animals: A History-Based Introduction to Contemporary Translational Applications
Pharmaco-EEG Studies in Animals: A History-Based Introduction to Contemporary Translational Applications
Current research on the effects of pharmacological agents on human neurophysiology finds its roots in animal research, which is also reflected in contemporary animal pharmaco-elect...
Comparing MEG and EEG measurement set-ups for a brain–computer interface based on selective auditory attention
Comparing MEG and EEG measurement set-ups for a brain–computer interface based on selective auditory attention
Abstract
Auditory attention modulates auditory evoked responses to target vs. non-target sounds in electro- and magnetoencephalographic (EEG/MEG) recordings. Employ...
Computation of the electroencephalogram (EEG) from network models of point neurons
Computation of the electroencephalogram (EEG) from network models of point neurons
Abstract
The electroencephalogram (EEG) is one of the main tools for non-invasively studying brain function and dysfunction. To better interpret EEGs in terms of ne...
Insights Into Thrombopoiesis From Infused Human Megakaryocytes Into Mice
Insights Into Thrombopoiesis From Infused Human Megakaryocytes Into Mice
Abstract
Thrombopoiesis is the process by which megakaryocytes (Megs) release platelets (Plts), but issues remain as to the detailed in vivo mechanisms underlying th...