Javascript must be enabled to continue!
High-Throughput Solid Phase Extraction for Targeted and Non-Targeted Exposomics
View through CrossRef
Characterizing the chemical exposome relies on advanced instrumentation including tandem mass spectrometry coupled to liquid chromatography (LC-MS/MS), and non-targeted analysis (NTA) using high-resolution MS. How-ever, proper sample pretreatment, balancing broad analyte coverage, method robustness, and throughput remain a major bottleneck in exposomics. Here, we developed a robust and scalable solid phase extraction (SPE) proto-col in 96-well format for human urine and plasma and optimized it for a panel of 94 highly diverse environmen-tal and food-related contaminants (LogP -0.7 ~ 6.8). Extraction recoveries (RE) and signal suppression and en-hancement (SSE) were determined using targeted LC-MS/MS. Acceptable REs (60% - 140%) were achieved for >70% of all analytes, and acceptable SSE values (60% -140%) for 86% and 90% in urine and plasma, respective-ly. Subsequently, the method was transferred to 96-well format, significantly improving throughput to meet the capacity requirements needed for exposome-wide association studies (ExWAS). The established workflow is approximately 10× faster than routinely used metabolomics-based protein precipitation approaches when com-paring the estimated total analysis time for 1000 samples. The method’s applicability for NTA and suspect screening was tested and compared to a generic protein precipitation protocol using NIST standard reference materials for urine (SRM 3672) and plasma (SRM 1950). Favorable performance was shown for the protein pre-cipitation workflow while the SPE protocol demonstrated promising results. The developed workflow is thus not only superior for future high-throughput targeted exposomics but also offers an option for NTA applications. The presented well-balanced approach is scalable and also applicable to research in the fields of pharmacology, food safety, or systems toxicology.
Title: High-Throughput Solid Phase Extraction for Targeted and Non-Targeted Exposomics
Description:
Characterizing the chemical exposome relies on advanced instrumentation including tandem mass spectrometry coupled to liquid chromatography (LC-MS/MS), and non-targeted analysis (NTA) using high-resolution MS.
How-ever, proper sample pretreatment, balancing broad analyte coverage, method robustness, and throughput remain a major bottleneck in exposomics.
Here, we developed a robust and scalable solid phase extraction (SPE) proto-col in 96-well format for human urine and plasma and optimized it for a panel of 94 highly diverse environmen-tal and food-related contaminants (LogP -0.
7 ~ 6.
8).
Extraction recoveries (RE) and signal suppression and en-hancement (SSE) were determined using targeted LC-MS/MS.
Acceptable REs (60% - 140%) were achieved for >70% of all analytes, and acceptable SSE values (60% -140%) for 86% and 90% in urine and plasma, respective-ly.
Subsequently, the method was transferred to 96-well format, significantly improving throughput to meet the capacity requirements needed for exposome-wide association studies (ExWAS).
The established workflow is approximately 10× faster than routinely used metabolomics-based protein precipitation approaches when com-paring the estimated total analysis time for 1000 samples.
The method’s applicability for NTA and suspect screening was tested and compared to a generic protein precipitation protocol using NIST standard reference materials for urine (SRM 3672) and plasma (SRM 1950).
Favorable performance was shown for the protein pre-cipitation workflow while the SPE protocol demonstrated promising results.
The developed workflow is thus not only superior for future high-throughput targeted exposomics but also offers an option for NTA applications.
The presented well-balanced approach is scalable and also applicable to research in the fields of pharmacology, food safety, or systems toxicology.
Related Results
A data-centric perspective on exposomics data analysis
A data-centric perspective on exposomics data analysis
Abstract
Exposomics represents a systematic approach to investigate the etiology of diseases by formally integrating individuals’ entire environmental exposures and ...
7
th
International Symposium on Enabling Technologies for Life Sciences (ETP)
7
th
International Symposium on Enabling Technologies for Life Sciences (ETP)
The seventh in the series of ETP Symposia (see
Rapid Communications in Mass Spectrometry
2012,
26
, ...
The Development of High-Throughput Methods in the Study of All-Solid Li-Electrolytes
The Development of High-Throughput Methods in the Study of All-Solid Li-Electrolytes
High-throughput experimentation is a fast and efficient methodology for materials discovery, screening, and optimization. It has, therefore, garnered a lot of attention from batter...
The Development of High-Throughput Methods in the Study of Solid State Li-Electrolytes
The Development of High-Throughput Methods in the Study of Solid State Li-Electrolytes
High-throughput experimentation is a fast and efficient methodology for materials discovery, screening, and optimization. It has, therefore, garnered a lot of attention from batter...
Advancing AI/ML-driven chemical exposomics to identify biologically relevant environmental exposures
Advancing AI/ML-driven chemical exposomics to identify biologically relevant environmental exposures
Exposomics aims to systematically measure environmental exposures that an individual experiences across all stages of life, from conception to death, and link them to health and di...
High resolution mass spectrometry to investigate the human exposome: Where are We?
High resolution mass spectrometry to investigate the human exposome: Where are We?
Abstract
Despite the significant role of the environment in health and disease, the accurate assessment of environmental exposures remains underdeveloped compared...
Fabrication of Ruthenium-Based Cathode Material/Solid Electrolyte Composites
Fabrication of Ruthenium-Based Cathode Material/Solid Electrolyte Composites
Introduction
Oxide-based all-solid-state batteries (ASSBs) are considered safe due to their chemical stability and are attracting attention as a pow...
An integrated model for process parameter adjustment to recover throughput shortage in semiconductor assembly: A case study
An integrated model for process parameter adjustment to recover throughput shortage in semiconductor assembly: A case study
Purpose: Existing productivity improvements activities such as inventory buffer, overall equipment effectiveness (OEE) and total productive maintenance (TPM) do not analytically as...

