Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Symmetrization of the Blood Glucose Measurement Scale and Its Applications

View through CrossRef
OBJECTIVE To introduce a data transformation that enhances the power of blood glucose data analyses. RESEARCH DESIGN AND METHODS In the standard blood glucose scale, hypoglycemia (blood glucose, <3.9 mmol/l) and hyperglycemia (blood glucose, >10 mmol/l) have very different ranges, and euglycemia is not central in the entire blood glucose range (1.1–33.3 mmol/l). Consequently, the scale is not symmetric and its clinical center (blood glucose, 6–7 mmol/l) is distant from its numerical center (blood glucose, 17 mmol/l). As a result, when blood glucose readings are analyzed, the assumptions of many parametric statistics are routinely violated. We propose a logarithmic data transformation that matches the clinical and numerical center of the blood glucose scale, thus making the transformed data symmetric. RESULTS The transformation normalized 203 out of 205 data samples containing 13,584 blood glucose readings of 127 type 1 diabetic individuals. An example illustrates that the mean and standard deviation based on transformed, rather than on raw, data better described subject's blood glucose distribution. Based on transformed data: 1) the low blood glucose index predicted the occurrence of severe hypoglycemia, while the raw blood glucose data (and glycosylated hemoglobin levels) did not; 2) the high blood glucose index correlated with the subjects' glycosylated hemoglobin (r = 0.63, P <0.001); and 3) the low plus high blood glucose index was more sensitive than the raw data to a treatment (blood glucose awareness training) designed to reduce the range of blood glucose fluctuations. CONCLUSIONS Using symmetrized, instead of raw, blood glucose data strengthens the existing data analysis procedures and allows for the development of new statistical techniques. It is proposed that raw blood glucose data should be routinely transformed to a symmetric distribution before using parametric statistics.
Title: Symmetrization of the Blood Glucose Measurement Scale and Its Applications
Description:
OBJECTIVE To introduce a data transformation that enhances the power of blood glucose data analyses.
RESEARCH DESIGN AND METHODS In the standard blood glucose scale, hypoglycemia (blood glucose, <3.
9 mmol/l) and hyperglycemia (blood glucose, >10 mmol/l) have very different ranges, and euglycemia is not central in the entire blood glucose range (1.
1–33.
3 mmol/l).
Consequently, the scale is not symmetric and its clinical center (blood glucose, 6–7 mmol/l) is distant from its numerical center (blood glucose, 17 mmol/l).
As a result, when blood glucose readings are analyzed, the assumptions of many parametric statistics are routinely violated.
We propose a logarithmic data transformation that matches the clinical and numerical center of the blood glucose scale, thus making the transformed data symmetric.
RESULTS The transformation normalized 203 out of 205 data samples containing 13,584 blood glucose readings of 127 type 1 diabetic individuals.
An example illustrates that the mean and standard deviation based on transformed, rather than on raw, data better described subject's blood glucose distribution.
Based on transformed data: 1) the low blood glucose index predicted the occurrence of severe hypoglycemia, while the raw blood glucose data (and glycosylated hemoglobin levels) did not; 2) the high blood glucose index correlated with the subjects' glycosylated hemoglobin (r = 0.
63, P <0.
001); and 3) the low plus high blood glucose index was more sensitive than the raw data to a treatment (blood glucose awareness training) designed to reduce the range of blood glucose fluctuations.
CONCLUSIONS Using symmetrized, instead of raw, blood glucose data strengthens the existing data analysis procedures and allows for the development of new statistical techniques.
It is proposed that raw blood glucose data should be routinely transformed to a symmetric distribution before using parametric statistics.

Related Results

[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED]Guardian Blood Balance Reviews (Works Or Hoax) Does Guardian Botanicals Blood Balance AU Really Works? Read Updated Report! Diabetes and Hypertension is such a health p...
ANALISIS PERTIMBANGAN MAHKAMAH AGUNG DALAM MENGABULKAN KASASI TERDAKWA (STUDI PUTUSAN NOMOR 2959/K/PID.SUS/2022)
ANALISIS PERTIMBANGAN MAHKAMAH AGUNG DALAM MENGABULKAN KASASI TERDAKWA (STUDI PUTUSAN NOMOR 2959/K/PID.SUS/2022)
<p><em><span class="markedContent"><span style="left: calc(var(--scale-factor)*195.53px); top: calc(var(--scale-factor)*496.87px); font-size: calc(var(--scale-...
Glucose intolerance is associated with resting heart rate among individuals without diabetes
Glucose intolerance is associated with resting heart rate among individuals without diabetes
Elevated resting heart rate is associated with cardiovascular diseases and all-cause mortality. Unmanaged diabetes is associated with high blood pressure and high resting heart rat...
KEDUDUKAN AHLI BAHASA DALAM PEMBUKTIAN PERKARA PENCEMARAN NAMA BAIK (STUDI PUTUSAN NOMOR: 47/PID.SUS/2019/PN. MGT)
KEDUDUKAN AHLI BAHASA DALAM PEMBUKTIAN PERKARA PENCEMARAN NAMA BAIK (STUDI PUTUSAN NOMOR: 47/PID.SUS/2019/PN. MGT)
<em><span id="page3R_mcid52" class="markedContent"><span style="left: calc(var(--scale-factor)*125.30px); top: calc(var(--scale-factor)*539.11px); font-size: calc(va...
Effects of herbal tea (Platostoma palustre) on blood glucose regulation in vivo
Effects of herbal tea (Platostoma palustre) on blood glucose regulation in vivo
Platostoma palustre jelly is a traditional food. Platostoma palustre has been used as folk medicine and is effective against heat-shock, hypertension and diabetes. Therefore, the a...
Twenty‐four‐hour variations in blood glucose level in Japanese type 2 diabetes patients based on continuous glucose monitoring
Twenty‐four‐hour variations in blood glucose level in Japanese type 2 diabetes patients based on continuous glucose monitoring
AbstractAims/IntroductionHigh fluctuations in blood glucose are associated with various complications. The correlation between glycated hemoglobin (HbA1c) level and fluctuations in...

Back to Top