Surface-Based vs. Voxel-Based Finite Element Head Models: Comparative Analyses of Strain Responses

View through CrossRef
Abstract Finite element (FE) models of the human head are important injury assessment tools but developing a high-quality, hexahedral-meshed FE head model without compromising geometric accuracy is a challenging task. Important brain features, such as the cortical folds and ventricles, were captured only in a handful of FE head models that were primarily developed from two meshing techniques, i.e., surface-based meshing with conforming elements to capture the interfacial boundaries and voxel-based meshing by converting the segmented voxels into elements with and without mesh smoothing. Despite these advancements, little knowledge existed of how similar the strain responses were between surface- and voxel-based FE head models. This study uniquely addressed this gap by presenting three anatomically detailed models - a surface-based model with conforming meshes to capture the cortical folds-subarachnoid cerebrospinal fluid and brain-ventricle interfaces, and two voxel-based models (with and without mesh smoothing) - derived from the same imaging dataset. All numerical settings in the three models were exactly the same, except for the meshes. These three models were employed to simulate head impacts. The results showed that, when calculating commonly used injury metrics, including the percentile strains below the maximum (e.g., 99 percentile strain) and the volume of brain element with the strain over certain thresholds, the responses of the three models were virtually identical. Different strain patterns existed between the surface- and the voxel-based models at the interfacial boundary (e.g., sulci and gyri in the cortex, regions adjacent to the falx and tentorium) with strain differences exceeding 0.1, but remarkable similarities were noted at the non-interfacial region. The mesh smoothing procedure marginally reduced the strain discrepancies between the voxel- and surface-based model. This study yielded new quantitative insights into the general similarity in the strain responses between the surface- and voxel-based FE head models and underscored that caution should be exercised when using the strain at the interface to predict injury.
Title: Surface-Based vs. Voxel-Based Finite Element Head Models: Comparative Analyses of Strain Responses
Description:
Abstract Finite element (FE) models of the human head are important injury assessment tools but developing a high-quality, hexahedral-meshed FE head model without compromising geometric accuracy is a challenging task.
Important brain features, such as the cortical folds and ventricles, were captured only in a handful of FE head models that were primarily developed from two meshing techniques, i.
e.
, surface-based meshing with conforming elements to capture the interfacial boundaries and voxel-based meshing by converting the segmented voxels into elements with and without mesh smoothing.
Despite these advancements, little knowledge existed of how similar the strain responses were between surface- and voxel-based FE head models.
This study uniquely addressed this gap by presenting three anatomically detailed models - a surface-based model with conforming meshes to capture the cortical folds-subarachnoid cerebrospinal fluid and brain-ventricle interfaces, and two voxel-based models (with and without mesh smoothing) - derived from the same imaging dataset.
All numerical settings in the three models were exactly the same, except for the meshes.
These three models were employed to simulate head impacts.
The results showed that, when calculating commonly used injury metrics, including the percentile strains below the maximum (e.
g.
, 99 percentile strain) and the volume of brain element with the strain over certain thresholds, the responses of the three models were virtually identical.
Different strain patterns existed between the surface- and the voxel-based models at the interfacial boundary (e.
g.
, sulci and gyri in the cortex, regions adjacent to the falx and tentorium) with strain differences exceeding 0.
1, but remarkable similarities were noted at the non-interfacial region.
The mesh smoothing procedure marginally reduced the strain discrepancies between the voxel- and surface-based model.
This study yielded new quantitative insights into the general similarity in the strain responses between the surface- and voxel-based FE head models and underscored that caution should be exercised when using the strain at the interface to predict injury.

Related Results

Primerjalna književnost na prelomu tisočletja
Primerjalna književnost na prelomu tisočletja
In a comprehensive and at times critical manner, this volume seeks to shed light on the development of events in Western (i.e., European and North American) comparative literature ...
A novel contact interaction formulation for voxel-based micro-finite-element models of bone
A novel contact interaction formulation for voxel-based micro-finite-element models of bone
Voxel-based micro-finite-element (μFE) models are used extensively in bone mechanics research. A major disadvantage of voxel-based μFE models is that voxel surface jaggedness cause...
Image-guided modeling, fabrication and micromechanical analysis of bone and heterogeneous structure
Image-guided modeling, fabrication and micromechanical analysis of bone and heterogeneous structure
This research has developed a novel image-based modeling approach and a direct fabrication technique for design and manufacturing of multi-scale, custom designed bone scaffolds and...
Functional-Voxel Modelling of Bezie Curves
Functional-Voxel Modelling of Bezie Curves
The problem of this research is the impossibility of applying parametric functions in theoretical-multiple modeling, that significantly narrows the range of problems solved by anal...
Effect of Pre-Strain and Strain Rate on Deformation and Fracture Behavior of Automotive Grade Interstitial Free Steel Sheets
Effect of Pre-Strain and Strain Rate on Deformation and Fracture Behavior of Automotive Grade Interstitial Free Steel Sheets
The effect of pre-strain and strain rate on deformation behavior of two grades of interstitial free (IF) steel sheets, industrially referred as EIF and HIF, of thickness 0.7 mm hav...
SCF Equations for T/Y and K Square-to-Round Tubular Joint
SCF Equations for T/Y and K Square-to-Round Tubular Joint
Summary A parametric stress analysis of T/Y and K square-to-round tubular joints subjected to axial loads and in-plane and out-of-plane bending moments has been p...
A Review on Biomechanics and Development of Finite Element Models of Human Head Neck System
A Review on Biomechanics and Development of Finite Element Models of Human Head Neck System
Abstract: The biomechanics of human head neck system could be better understood by creating finite element models of the same that accurately represents most of the components of h...