Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

3DμF - Interactive Design Environment for Continuous Flow Microfluidic Devices

View through CrossRef
Abstract The design of microfluidic Lab on a Chip (LoC) systems is an onerous task requiring specialized skills in fluid dynamics, mechanical design drafting, and manufacturing. Engineers face significant challenges during the labor-intensive process of designing microfluidic devices, with very few specialized tools that help automate the process. Typical design iterations require the engineer to research the architecture, manually draft the device layout, optimize for manufacturing processes, and manually calculate and program the valve sequences that operate the microfluidic device. The problem compounds when engineers not only have to test the functionality of the chip but are also expected to optimize them for the robust execution of biological assays. In this paper, we present an interactive tool for designing continuous flow microfluidic devices. 3D μ F is the first completely open source interactive microfluidic system designer that readily supports state of the art design automation algorithms. Through various case studies, we show 3D μ F can be used to reproduce designs from literature, provide metrics for evaluating microfluidic design complexity and showcase how 3D μ F is a platform for integrating a wide assortment of engineering techniques used in the design of microfluidic devices as a part of the standard design workflow.
Title: 3DμF - Interactive Design Environment for Continuous Flow Microfluidic Devices
Description:
Abstract The design of microfluidic Lab on a Chip (LoC) systems is an onerous task requiring specialized skills in fluid dynamics, mechanical design drafting, and manufacturing.
Engineers face significant challenges during the labor-intensive process of designing microfluidic devices, with very few specialized tools that help automate the process.
Typical design iterations require the engineer to research the architecture, manually draft the device layout, optimize for manufacturing processes, and manually calculate and program the valve sequences that operate the microfluidic device.
The problem compounds when engineers not only have to test the functionality of the chip but are also expected to optimize them for the robust execution of biological assays.
In this paper, we present an interactive tool for designing continuous flow microfluidic devices.
3D μ F is the first completely open source interactive microfluidic system designer that readily supports state of the art design automation algorithms.
Through various case studies, we show 3D μ F can be used to reproduce designs from literature, provide metrics for evaluating microfluidic design complexity and showcase how 3D μ F is a platform for integrating a wide assortment of engineering techniques used in the design of microfluidic devices as a part of the standard design workflow.

Related Results

Design
Design
Conventional definitions of design rarely capture its reach into our everyday lives. The Design Council, for example, estimates that more than 2.5 million people use design-related...
Flow Cytometry, Beads, and Microchannels
Flow Cytometry, Beads, and Microchannels
Microfluidic devices generally consume microliter to submicroliter volumes of sample and are thus well suited for use when the required reagents are scarce or expensive. Because mi...
Microfluidic Devices: Useful Tools for Bioprocess Intensification
Microfluidic Devices: Useful Tools for Bioprocess Intensification
The dawn of the new millennium saw a trend towards the dedicated use of microfluidic devices for process intensification in biotechnology. As the last decade went by, it became evi...
Microfluidic Devices: Applications and Role of Surface Wettability in Its Fabrication
Microfluidic Devices: Applications and Role of Surface Wettability in Its Fabrication
Microfluidic devices are based upon the behavior of fluids at the microenvironment level. They offer innumerable applications in the field of science and technology. Their scope is...
Implantable Microfluidic Device: An Epoch of Technology
Implantable Microfluidic Device: An Epoch of Technology
:Implantable microfluidic devices are milestones in developing devices that can measure parameters like ocular pressure and blood glucose level or deliver various components for th...
Microfluidic Acoustic Metamaterial SAW Based Sensor
Microfluidic Acoustic Metamaterial SAW Based Sensor
Introduction. Microacoustic sensors based on surface acoustic wave (SAW) devices allow the sensor integration into a wafer based microfluidic analytical platforms such as lab-on-a-...
Electrical contactless microfluidic flow quantification
Electrical contactless microfluidic flow quantification
Precise sensing of microfluidic flow is essential to advancing lab-on-a-chip development and the downstream medical applications. Contactless microfluidic flow interrogation is non...
Fabrication of Transparent and Flexible Digital Microfluidics Devices
Fabrication of Transparent and Flexible Digital Microfluidics Devices
This study proposed a fabrication method for thin, film-based, transparent, and flexible digital microfluidic devices. A series of characterizations were also conducted with the fa...

Back to Top