Measurement of blood pressure using automatic monitors in patients with atrial fibrillation: a comparative analysis
View through CrossRef
Aim: to specify indications for use of distinct types of blood pressure monitors (mechanical, automatic with arrhythmia detector and upper arm cuff, and automatic with arrhythmia detector and wrist cuff) in patients with atrial fibrillation (AFib). Patients and Methods: 202 patients (mean age 61.8 ± 1.3 years) with paroxysmal AFib of any origin occurred no more than 1 month ago and atrial tachysystole were enrolled. All patients had a history of hypertension of various severity. This study was conducted in three units, i.e., ICU, ED, and therapeutic department. Blood pressure (BP) measurements were performed at 8 a.m., 12 p.m., and 4 p.m. using various types of BP monitors in turn, i.e., mechanical BP monitor (whose readings were considered reference values), automatic BP monitor OMRON M2 BASIC HEM-7121-ALRU (OMRON M2 BASIC) with upper arm cuff, automatic BP monitor OMRON RS2 HEM-6121-Ru (OMRON RS2) with wrist cuff, and automatic BP monitors of other manufacturers with upper arm cuff (B1 and A1) or wrist cuff (B2 and A2). Results: in patients with AFib of any severity, BP readings measured by automatic BP monitors OMRON M2 BASIC and OMRON RS2 demonstrate no significant differences compared to BP readings measured by mechanical BP monitor. Meanwhile, BP readings measured by BP monitors of other manufacturers (A1, A2, B1, and B2) were significantly different from reference values. The more severe was arrhythmia, the more significant the differences were. Conclusions: automatic BP monitors OMRON M2 BASIC and OMRON RS2 that provide as accurate as possible BP readings can be recommended for measuring BP in patients with AFib of any severity in ED, outpatient wards, and at home (self-control). KEYWORDS: hypertension, atrial fibrillation, blood pressure measurement, blood pressure variability, blood pressure monitor. FOR CITATION: Vertkin A.L., Sycheva A.S., Kebina A.L. et al. Measurement of blood pressure using automatic monitors in patients with atrial fibrillation: a comparative analysis. Russian Medical Inquiry. 2021;5(4):189–195 (in Russ.). DOI: 10.32364/2587-6821-2021-5-4-189-195.
LLC Russian Medical Journal
Title: Measurement of blood pressure using automatic monitors in patients with atrial fibrillation: a comparative analysis
Description:
Aim: to specify indications for use of distinct types of blood pressure monitors (mechanical, automatic with arrhythmia detector and upper arm cuff, and automatic with arrhythmia detector and wrist cuff) in patients with atrial fibrillation (AFib).
Patients and Methods: 202 patients (mean age 61.
8 ± 1.
3 years) with paroxysmal AFib of any origin occurred no more than 1 month ago and atrial tachysystole were enrolled.
All patients had a history of hypertension of various severity.
This study was conducted in three units, i.
e.
, ICU, ED, and therapeutic department.
Blood pressure (BP) measurements were performed at 8 a.
m.
, 12 p.
m.
, and 4 p.
m.
using various types of BP monitors in turn, i.
e.
, mechanical BP monitor (whose readings were considered reference values), automatic BP monitor OMRON M2 BASIC HEM-7121-ALRU (OMRON M2 BASIC) with upper arm cuff, automatic BP monitor OMRON RS2 HEM-6121-Ru (OMRON RS2) with wrist cuff, and automatic BP monitors of other manufacturers with upper arm cuff (B1 and A1) or wrist cuff (B2 and A2).
Results: in patients with AFib of any severity, BP readings measured by automatic BP monitors OMRON M2 BASIC and OMRON RS2 demonstrate no significant differences compared to BP readings measured by mechanical BP monitor.
Meanwhile, BP readings measured by BP monitors of other manufacturers (A1, A2, B1, and B2) were significantly different from reference values.
The more severe was arrhythmia, the more significant the differences were.
Conclusions: automatic BP monitors OMRON M2 BASIC and OMRON RS2 that provide as accurate as possible BP readings can be recommended for measuring BP in patients with AFib of any severity in ED, outpatient wards, and at home (self-control).
KEYWORDS: hypertension, atrial fibrillation, blood pressure measurement, blood pressure variability, blood pressure monitor.
FOR CITATION: Vertkin A.
L.
, Sycheva A.
S.
, Kebina A.
L.
et al.
Measurement of blood pressure using automatic monitors in patients with atrial fibrillation: a comparative analysis.
Russian Medical Inquiry.
2021;5(4):189–195 (in Russ.
).
DOI: 10.
32364/2587-6821-2021-5-4-189-195.
Related Results
Rethinking Anticoagulation in Kidney Disease and Kidney Transplantation
Rethinking Anticoagulation in Kidney Disease and Kidney Transplantation
BackgroundA clinical dilemma exists in patients with CKD, ESKD, and after kidney transplantation, as they face concurrent risks of both thromboembolic and hemorrhagic complications...
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED]Guardian Blood Balance Reviews (Works Or Hoax) Does Guardian Botanicals Blood Balance AU Really Works? Read Updated Report! Diabetes and Hypertension is such a health p...
Inter‐Relationships Between Atrial Flutter and Atrial Fibrillation
Inter‐Relationships Between Atrial Flutter and Atrial Fibrillation
It has been appreciated for a long time that atrial flutter and atrial fibrillation have a clinical relationship. Now, with the technological advances that permit more sophisticate...
Adiponectin and Lone atrial fibrillation
Adiponectin and Lone atrial fibrillation
Objective: Lone atrial fibrillation is an idiopathic arrhythmia seen in younger individuals without any secondary disease. Adiponectin is an endogenous adipocytokine that increases...
Beyond Coronary Risk: Clinical Scores as Predictors of Atrial Fibrillation in Chronic Coronary Syndrome
Beyond Coronary Risk: Clinical Scores as Predictors of Atrial Fibrillation in Chronic Coronary Syndrome
Atrial fibrillation frequently coexists with chronic coronary syndrome, sharing common cardiovascular risk factors and pathophysiological mechanisms. Identifying patients with chro...
ASSA13-03-9 Decreased Expression of Small-Conductance Ca2+-Activated K+ Channels SK1, SK2, and SK3 in Patients with Persistent Atrial Fibrillation
ASSA13-03-9 Decreased Expression of Small-Conductance Ca2+-Activated K+ Channels SK1, SK2, and SK3 in Patients with Persistent Atrial Fibrillation
Background
Small-conductance Ca2+-activated K+ channels (SK channels) have been reported involved in atrial fibrillation (AF) as a new ion channel candidates, as ...
RELATIONSHIP BETWEEN ATRIAL FIBRILLATION CARDIOVERSION AND F
RELATIONSHIP BETWEEN ATRIAL FIBRILLATION CARDIOVERSION AND F
Objectives
To investigate the relationship between atrial fibrillation cardioversion and f wave in electrocardiogram, providing an ordinary and noninvasive method...
Left atrial appendage anatomy and function: short term response to sustained atrial fibrillation
Left atrial appendage anatomy and function: short term response to sustained atrial fibrillation
OBJECTIVE
To determine whether there is significant atrial or atrial appendage enlargement or functional remodelling as a result of one to two months of sustained...