Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Fracture resistance and mode of failure of modified Polyether-ether-ketone versus lithium disilicate endocrowns

View through CrossRef
Abstract Purpose The current study aimed to compare modified Polyether-ether-ketone's fracture resistance and failure mode versus lithium disilicate glass–ceramic endocrowns. Materials and methods A total of 16 butt-joint endocrown specimens on mandibular second molar teeth were fabricated and divided into two equivalent groups; Pressable modified Polyether-ether-ketone (PEEK) (BioHPP®) and Pressable lithium disilicate glass ceramic (IPS e.max® Press). A computer-aided design/computer-aided manufacturing system was used to digitally create and milled wax patterns. Final restorations were cemented each to its corresponding prepared tooth. Thermomechanical cycling loading representing one year of clinical service was done in a chewing simulator. Fracture resistance was evaluated utilizing a universal testing machine. The failure mode was evaluated by inspecting fractured surfaces using a Stereomicroscope and further examined by a Scanning Electron Microscope (SEM) amongst both groups. Results A statistically significant variation in fracture resistance was recorded with a mean load of (2762.96 ± 216.15 N) for modified PEEK and (2175.91 ± 267.72 N) for lithium disilicate glass–ceramic endocrowns. Conclusion Modified PEEK endocrowns have higher fracture resistance than lithium disilicate glass–ceramic endocrowns. Moreover, the likeliness of catastrophic fracture in molars receiving endodontic treatment restored by modified PEEK is less than teeth restored with lithium disilicate glass ceramics.
Title: Fracture resistance and mode of failure of modified Polyether-ether-ketone versus lithium disilicate endocrowns
Description:
Abstract Purpose The current study aimed to compare modified Polyether-ether-ketone's fracture resistance and failure mode versus lithium disilicate glass–ceramic endocrowns.
Materials and methods A total of 16 butt-joint endocrown specimens on mandibular second molar teeth were fabricated and divided into two equivalent groups; Pressable modified Polyether-ether-ketone (PEEK) (BioHPP®) and Pressable lithium disilicate glass ceramic (IPS e.
max® Press).
A computer-aided design/computer-aided manufacturing system was used to digitally create and milled wax patterns.
Final restorations were cemented each to its corresponding prepared tooth.
Thermomechanical cycling loading representing one year of clinical service was done in a chewing simulator.
Fracture resistance was evaluated utilizing a universal testing machine.
The failure mode was evaluated by inspecting fractured surfaces using a Stereomicroscope and further examined by a Scanning Electron Microscope (SEM) amongst both groups.
Results A statistically significant variation in fracture resistance was recorded with a mean load of (2762.
96 ± 216.
15 N) for modified PEEK and (2175.
91 ± 267.
72 N) for lithium disilicate glass–ceramic endocrowns.
Conclusion Modified PEEK endocrowns have higher fracture resistance than lithium disilicate glass–ceramic endocrowns.
Moreover, the likeliness of catastrophic fracture in molars receiving endodontic treatment restored by modified PEEK is less than teeth restored with lithium disilicate glass ceramics.

Related Results

Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
Marginal Fit Comparison of CAD/CAM Crowns Milled from Two Different Materials
Marginal Fit Comparison of CAD/CAM Crowns Milled from Two Different Materials
AbstractPurposeTo evaluate the marginal fit of CAD/CAM copings milled from hybrid ceramic (Vita Enamic) blocks and lithium disilicate (IPS e.max CAD) blocks, and to evaluate the ef...
Stochastic Propagation of Discrete Fracture Networks
Stochastic Propagation of Discrete Fracture Networks
This reference is for an abstract only. A full paper was not submitted for this conference. Abstract Fractures are ubiquitous st...
Marginal integrity and clinical evaluation of polyetheretherketone (PEEK) versus lithium disilicate (E-Max) endocrowns
Marginal integrity and clinical evaluation of polyetheretherketone (PEEK) versus lithium disilicate (E-Max) endocrowns
Aim:  Evaluate the marginal integrity and Clinical performance of PEEK endocrowns compared to lithium disilicate (E-Max) ceramic endocrowns. Methodology: Twenty six endocrowns were...
Polyether Antibiotics
Polyether Antibiotics
AbstractSeveral polyether antibiotics have found commercial application as anticoccidials in poultry farming and in improvement of feed efficiency for ruminants. These antibiotics ...
In vitro Comparison of the Microhardness of Lithium Disilicate and Monolithic and Multilayered Fixed Prosthodontic Materials
In vitro Comparison of the Microhardness of Lithium Disilicate and Monolithic and Multilayered Fixed Prosthodontic Materials
Micro-hardness is a fundamental property of prosthodontic restorative materials, as it affects their resistance to surface deformation, wear, and long-term clinical performance. Th...
Sequential Propagation of Multiple Fractures in Horizontal Wells
Sequential Propagation of Multiple Fractures in Horizontal Wells
ABSTRACT: Simultaneous fracturing and zipper fracturing of horizontal wells has rapidly evolved to the development of unconventional oil and gas. The fracture int...

Back to Top