Javascript must be enabled to continue!
Titanium Mesh Versus Polyetheretherketone (PEEK) in Cranioplasty: A Systematic Review and Meta-Analysis of Complications and Clinical Outcomes
View through CrossRef
Abstract
Background
Cranioplasty following decompressive craniectomy can be performed using various implant materials, with titanium and polyetheretherketone (PEEK) being the most commonly used synthetic options. However, their comparative safety and clinical performance remain debated. This systematic review and meta-analysis aimed to compare titanium-based cranioplasty with PEEK and other synthetic or autologous materials regarding implant survival, complications, functional outcomes, cosmetic results, and operative metrics.
Methods
This systematic review was conducted in accordance with the
Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020
guidelines and registered in PROSPERO (CRD). A comprehensive search was performed in PubMed, Embase, Scopus, Web of Science, and the Cochrane Database of Systematic Reviews (CDSR) without language or date restrictions. A total of 1,026 records were identified (Embase n = 263, Web of Science n = 272, Scopus n = 293, PubMed n = 193). After removal of 550 duplicates, 78 articles underwent full-text review, and 38 comparative studies met the eligibility criteria for qualitative synthesis. Three studies directly comparing titanium and PEEK with extractable infection data were included in the meta-analysis. Risk of bias was assessed using Joanna Briggs Institute (JBI) tools.
Results
Forty-one studies encompassing heterogeneous patient populations and study designs were included, predominantly retrospective cohort studies. Titanium demonstrated shorter operative times and lower intraoperative blood loss compared with autologous bone and, in most studies, compared with PEEK and PMMA. Implant survival outcomes were heterogeneous: PEEK frequently showed lower exposure rates but higher rates of subgaleal fluid collection. Compared with autologous bone, titanium had higher exposure rates but avoided resorption-related failures. Infection outcomes varied across materials; however, pooled meta-analysis demonstrated a significantly lower odds of postoperative infection with titanium compared with PEEK (random-effects model), with moderate heterogeneity. Functional and neurological outcomes were largely comparable across materials, and cosmetic satisfaction was generally high regardless of implant type.
Conclusions
Titanium cranioplasty provides favorable operative efficiency and competitive complication rates compared with alternative materials. While exposure risk may be higher than PEEK, pooled evidence suggests a lower infection risk with titanium. Overall, implant material selection should consider patient-specific risk factors, defect characteristics, and surgeon expertise. Further high-quality prospective studies are warranted to strengthen comparative evidence.
Title: Titanium Mesh Versus Polyetheretherketone (PEEK) in Cranioplasty: A Systematic Review and Meta-Analysis of Complications and Clinical Outcomes
Description:
Abstract
Background
Cranioplasty following decompressive craniectomy can be performed using various implant materials, with titanium and polyetheretherketone (PEEK) being the most commonly used synthetic options.
However, their comparative safety and clinical performance remain debated.
This systematic review and meta-analysis aimed to compare titanium-based cranioplasty with PEEK and other synthetic or autologous materials regarding implant survival, complications, functional outcomes, cosmetic results, and operative metrics.
Methods
This systematic review was conducted in accordance with the
Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020
guidelines and registered in PROSPERO (CRD).
A comprehensive search was performed in PubMed, Embase, Scopus, Web of Science, and the Cochrane Database of Systematic Reviews (CDSR) without language or date restrictions.
A total of 1,026 records were identified (Embase n = 263, Web of Science n = 272, Scopus n = 293, PubMed n = 193).
After removal of 550 duplicates, 78 articles underwent full-text review, and 38 comparative studies met the eligibility criteria for qualitative synthesis.
Three studies directly comparing titanium and PEEK with extractable infection data were included in the meta-analysis.
Risk of bias was assessed using Joanna Briggs Institute (JBI) tools.
Results
Forty-one studies encompassing heterogeneous patient populations and study designs were included, predominantly retrospective cohort studies.
Titanium demonstrated shorter operative times and lower intraoperative blood loss compared with autologous bone and, in most studies, compared with PEEK and PMMA.
Implant survival outcomes were heterogeneous: PEEK frequently showed lower exposure rates but higher rates of subgaleal fluid collection.
Compared with autologous bone, titanium had higher exposure rates but avoided resorption-related failures.
Infection outcomes varied across materials; however, pooled meta-analysis demonstrated a significantly lower odds of postoperative infection with titanium compared with PEEK (random-effects model), with moderate heterogeneity.
Functional and neurological outcomes were largely comparable across materials, and cosmetic satisfaction was generally high regardless of implant type.
Conclusions
Titanium cranioplasty provides favorable operative efficiency and competitive complication rates compared with alternative materials.
While exposure risk may be higher than PEEK, pooled evidence suggests a lower infection risk with titanium.
Overall, implant material selection should consider patient-specific risk factors, defect characteristics, and surgeon expertise.
Further high-quality prospective studies are warranted to strengthen comparative evidence.
Related Results
Stress and Strain Studies of Different Materials of the Dental Implant in Single Implant-Supported Prosthesis: A Finite Element Analysis
Stress and Strain Studies of Different Materials of the Dental Implant in Single Implant-Supported Prosthesis: A Finite Element Analysis
Background and Objective: The elastic modulus of carbon fiber reinforced polyetheretherketone is close to that of bone tissue and has proven to be an excellent substitute for titan...
In vitro physicochemical and biological properties of titanium alloy, zirconia, polyetheretherketone, and carbon fiber-reinforced polyetheretherketone
In vitro physicochemical and biological properties of titanium alloy, zirconia, polyetheretherketone, and carbon fiber-reinforced polyetheretherketone
Implant repair is a common means to restore the normal function of the hard tissues (bone or teeth). At present, the commonly and potentially used implant materials include titaniu...
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Evaluating the Science to Inform the Physical Activity Guidelines for Americans Midcourse Report
Abstract
The Physical Activity Guidelines for Americans (Guidelines) advises older adults to be as active as possible. Yet, despite the well documented benefits of physical activi...
CRANIOPLASTY: AUTOLOGOUS BONE GRAFT VS TITANIUM MESH
CRANIOPLASTY: AUTOLOGOUS BONE GRAFT VS TITANIUM MESH
Background: Cranioplasty (CP) is a neurosurgical procedure performed after decompressive craniectomy using autologous bone graft or various artificial materials.
Objective: To de...
Biomechanical Analysis of Pullout Strengths of Rotator Cuff and Glenoid Anchors: 2011 Update
Biomechanical Analysis of Pullout Strengths of Rotator Cuff and Glenoid Anchors: 2011 Update
Purpose
To evaluate the biomechanical and design characteristics of newer suture anchors.
Methods
...
Comparative Cost-Effectiveness of Cranioplasty Implants
Comparative Cost-Effectiveness of Cranioplasty Implants
Purpose:
The aim of this study was to compare operative duration and total hospital costs incurred for patients undergoing elective cranioplasty with a variety ...
Cranioplasty in Acoustic Neuroma Surgery
Cranioplasty in Acoustic Neuroma Surgery
AbstractObjectives To measure the incidence of postoperative headaches after retrosigmoid resections of acoustic neuromas and to evaluate the impact of cranioplasty on the preventi...
Surface modification of PEEK implants for craniofacial reconstruction and aesthetic augmentation—fiction or reality?
Surface modification of PEEK implants for craniofacial reconstruction and aesthetic augmentation—fiction or reality?
Facial implantology, a crucial facet of plastic and reconstructive surgery, focuses on optimizing implant materials for facial augmentation and reconstruction. This manuscript expl...

