Javascript must be enabled to continue!
Hemolysis of red blood cells during processing and storage
View through CrossRef
BACKGROUND: During processing and storage, red blood cells (RBCs) undergo changes and cell injury resulting in hemolysis. Mostly, the separation of whole blood in top‐and‐bottom quadruple bag systems with break openings takes less than 4 minutes. However, longer separation times are not uncommon. The aims were to investigate whether hemolysis is increased in RBCs with longer separation time (RBCs>6 min) compared to regular RBCs (RBCsreg), to measure hemolysis increase during storage and to study whether frequency of hemolytic donations is donor dependent.STUDY DESIGN AND METHODS: RBCs>6 min (n = 172) and 172 matched controls were tested for hemolysis on Days 1 and 21 RBC units from each group were stored at 4 ± 2°C and tested again after 5 weeks. Donor dependency was retrospectively investigated for 100 hemolytic RBC units.RESULTS: RBCs>6 min exhibited a higher mean hemolysis rate than RBCsreg (0.058% vs. 0.033%). Four RBC units were hemolytic (>0.8%), all RBCs>6 min (2.36%). During storage, hemolysis in both groups increased with 0.24%. Hemolysis frequency did not seem to be donor dependent.CONCLUSIONS: Increased separation time is a useful screening tool for potentially increased hemolysis rate in RBCs. Hemolysis rate increased during storage equally in both groups. Hemolysis frequency appears donor independent.
Title: Hemolysis of red blood cells during processing and storage
Description:
BACKGROUND: During processing and storage, red blood cells (RBCs) undergo changes and cell injury resulting in hemolysis.
Mostly, the separation of whole blood in top‐and‐bottom quadruple bag systems with break openings takes less than 4 minutes.
However, longer separation times are not uncommon.
The aims were to investigate whether hemolysis is increased in RBCs with longer separation time (RBCs>6 min) compared to regular RBCs (RBCsreg), to measure hemolysis increase during storage and to study whether frequency of hemolytic donations is donor dependent.
STUDY DESIGN AND METHODS: RBCs>6 min (n = 172) and 172 matched controls were tested for hemolysis on Days 1 and 21 RBC units from each group were stored at 4 ± 2°C and tested again after 5 weeks.
Donor dependency was retrospectively investigated for 100 hemolytic RBC units.
RESULTS: RBCs>6 min exhibited a higher mean hemolysis rate than RBCsreg (0.
058% vs.
0.
033%).
Four RBC units were hemolytic (>0.
8%), all RBCs>6 min (2.
36%).
During storage, hemolysis in both groups increased with 0.
24%.
Hemolysis frequency did not seem to be donor dependent.
CONCLUSIONS: Increased separation time is a useful screening tool for potentially increased hemolysis rate in RBCs.
Hemolysis rate increased during storage equally in both groups.
Hemolysis frequency appears donor independent.
Related Results
A-345 Effect of Hemolysis on Routine Blood Gas Analytes
A-345 Effect of Hemolysis on Routine Blood Gas Analytes
Abstract
Background
Hemolysis is a major pre-analytical concern for most laboratory analytes. Detection of hemolysis and mitigat...
Isolation And Characterization Of Biosurfactant Producing Bacteria From Different Environmental Soil Samples
Isolation And Characterization Of Biosurfactant Producing Bacteria From Different Environmental Soil Samples
Biosurfactants are natural substances produced by several bacterial and fungal organisms that are amphiphilic and are extracellular (a part of the cell membrane). Biosurfactants ca...
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED]Guardian Blood Balance Reviews (Works Or Hoax) Does Guardian Botanicals Blood Balance AU Really Works? Read Updated Report! Diabetes and Hypertension is such a health p...
Ghost cells as a two-phase blood analog fluid —fluorescent mechanical hemolysis detection
Ghost cells as a two-phase blood analog fluid —fluorescent mechanical hemolysis detection
Abstract
Background
This study investigated fluorescent hemolysis detection as an optical method to detect local hemolysis in mechanical circulatory support systems, addres...
Potable Water Sources, Household Hygiene, and Sanitation Practices in Ikpoba Okha LGA, Edo State: Implications for Public Health and Sustainable Water Management
Omoregie, Andrew Edosa.1 Omoregie Abieyuwa Peace2 Okoro, Enyinnaya Okoro.3
1 College of Medi
Potable Water Sources, Household Hygiene, and Sanitation Practices in Ikpoba Okha LGA, Edo State: Implications for Public Health and Sustainable Water Management
Omoregie, Andrew Edosa.1 Omoregie Abieyuwa Peace2 Okoro, Enyinnaya Okoro.3
1 College of Medi
BACKGROUND
Access to potable drinking water and sufficient sanitation continues to be an urgent global concern, particularly in developing regions where con...
Association between inflammatory and hemolysis markers in children with sickle cell disease
Association between inflammatory and hemolysis markers in children with sickle cell disease
Abstract
Background: Sickle cell disease (SCD) is a severe hemoglobin disorder characterized by recurrent vaso-occlusive...
Blood Cross Matching Without Anti-Human Globulin (AHG) and Bovine Serum: A New Interest for an Old Idea
Blood Cross Matching Without Anti-Human Globulin (AHG) and Bovine Serum: A New Interest for an Old Idea
Abstract
Introduction
Transfusion medicine promotes the safety of blood transfusions by rigorously testing to eliminate risks of infection and hemolytic. The efficacy (to correct ...
Red cell serological characterization of autoimmune hemolytic anemia in systemic lupus erythematosus patients
Red cell serological characterization of autoimmune hemolytic anemia in systemic lupus erythematosus patients
Abstract:
INTRODUCTION:
Autoimmune hemolytic anemia (AIHA) is a clinical condition with increased red cell destruction or decreased red cell surv...

