Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Velocity Measurement of EHD Flow Produced by Pin-Multi Concentric Ring Electrodes Generator

View through CrossRef
Study of EHD flow by using generator corona discharge with electrodes configuration of pin to multi concentric rings (MCR) and pin to single ring (SR) have been curried out. We measured the velocity of EHD flow and determined the comparison of velocity of EHD flow produced by pin to single ring electrodes. The pin needle was made by stainless steel with a length of 50 mm and a tip diameter of 0.14 mm. The multi-ring electrodes constracted by three concentric rings with a metal material connected to each other and each ring has a diameter of 24 mm, 16 mm and 8 mm in width and the same ring thickness is 2 mm and 3 mm. Single ring electrode has a diameter, width and thickness respectively 24 mm , 3 mm and 2 mm. EHD was generated by using a DC high voltage of 10 kV. Pin as an active electrode of corona discharge and concentric rings multi/single ring electrodes as ions collector and passive electrodes. The velocity of EHD flow was measured by a hot-wire anemometer. We found that the velocity of EHD flow with multi-ring concentric electrodes larger than a single ring electrode. The measurement of velocity for two cases of electrodes configuration were limited at the certain voltage due to breackdown and arc phenomena. The maximum velocity of the of EHD flow using a pin-multi rings concentric was 0.7 m/s at a voltage of 6 kV.
Title: Velocity Measurement of EHD Flow Produced by Pin-Multi Concentric Ring Electrodes Generator
Description:
Study of EHD flow by using generator corona discharge with electrodes configuration of pin to multi concentric rings (MCR) and pin to single ring (SR) have been curried out.
We measured the velocity of EHD flow and determined the comparison of velocity of EHD flow produced by pin to single ring electrodes.
The pin needle was made by stainless steel with a length of 50 mm and a tip diameter of 0.
14 mm.
The multi-ring electrodes constracted by three concentric rings with a metal material connected to each other and each ring has a diameter of 24 mm, 16 mm and 8 mm in width and the same ring thickness is 2 mm and 3 mm.
Single ring electrode has a diameter, width and thickness respectively 24 mm , 3 mm and 2 mm.
EHD was generated by using a DC high voltage of 10 kV.
Pin as an active electrode of corona discharge and concentric rings multi/single ring electrodes as ions collector and passive electrodes.
The velocity of EHD flow was measured by a hot-wire anemometer.
We found that the velocity of EHD flow with multi-ring concentric electrodes larger than a single ring electrode.
The measurement of velocity for two cases of electrodes configuration were limited at the certain voltage due to breackdown and arc phenomena.
The maximum velocity of the of EHD flow using a pin-multi rings concentric was 0.
7 m/s at a voltage of 6 kV.

Related Results

Abstract 19130: Is Early Hospital Discharge Safe After Adult Heart Transplantation?
Abstract 19130: Is Early Hospital Discharge Safe After Adult Heart Transplantation?
Introduction: The impact of early hospital discharge (EHD) after adult heart transplantation (HT) on longitudinal outcomes is unclear. Many HT recipients are intentiona...
Structured 3D Printed Dry ECG Electrodes Using Copper Based Filament
Structured 3D Printed Dry ECG Electrodes Using Copper Based Filament
Commercial wet Silver and Silver Chloride electrodes are used to monitor electrocardiogram (ECG) signals in numerous bioimpedance applications. These electrodes are frequently sing...
Performance Enhancement of Two Stages EHD Gas Pump in a Rectangular Channel With Uneven Voltages
Performance Enhancement of Two Stages EHD Gas Pump in a Rectangular Channel With Uneven Voltages
Abstract In this study, performance enhancement of a two stage electrohydrodynamic (EHD) gas pump in a rectangular channel has been evaluated by experimental measure...
Heat transport in turbulent electro-hydrodynamics
Heat transport in turbulent electro-hydrodynamics
<p>Electro-hydrodynamics (EHD) plays an important role in many industrial applications. Ink-jet printers, microwave drying facilities, and lab-on-a-chip devices utili...
Enzymatically hydrolyzed diet improves growth performance and intestinal microbiome in growing pigs
Enzymatically hydrolyzed diet improves growth performance and intestinal microbiome in growing pigs
BackgroundThe use of enzymes within pig feed can reduce the challenges associated with antibiotic-free animal feeding. However, this enzymatic effect is often limited by the intern...
Analisis Penyebab Pecahnya Cylinder Liner pada Generator Engine di Kapal MV. Kali Mas
Analisis Penyebab Pecahnya Cylinder Liner pada Generator Engine di Kapal MV. Kali Mas
Globalization has spurred the growth of the transportation sector. In this context, maintenance of generators on ship machinery is essential to ensure smooth ship operations. The g...
Abstract 9358: Time-Course of Left Ventricular Geometry in Arterial Hypertension: The Strong Heart Study
Abstract 9358: Time-Course of Left Ventricular Geometry in Arterial Hypertension: The Strong Heart Study
Background: The natural history of hypertensive heart disease is postulated to evolve from concentric LV geometry (LVG) to eccentric and eventually dilated LVG. However...
Material Flow Interaction in Multi-Pin Extrusion: A Study on Pin Height Variability and Process Predictability
Material Flow Interaction in Multi-Pin Extrusion: A Study on Pin Height Variability and Process Predictability
The increasing demand for lightweight multi-material structures, particularly in automotive and aerospace applications, requires robust and efficient joining technologies. Mechanic...

Back to Top