Javascript must be enabled to continue!
Performance Enhancement of Two Stages EHD Gas Pump in a Rectangular Channel With Uneven Voltages
View through CrossRef
Abstract
In this study, performance enhancement of a two stage electrohydrodynamic (EHD) gas pump in a rectangular channel has been evaluated by experimental measurement and numerical simulations. This study is implemented by a two stage EHD gas pump with uneven voltages for 8 emitting electrodes configuration to seek the relation between the number of stages and applied voltages. The EHD pump is evaluated for a combination of three different operating voltages (20 kV, 24 kV, and 28 kV) for further enhancement in its performance. To achieve the maximum enhancement, the emitting electrodes of the EHD gas pump are flush mounted on the channel walls so that the corona wind produced directly disturbs the boundary layer thickness and improves gas pumping. Velocities are measured at three cross-sections along the tube length and then integrated to obtain the volume flow rate. The numerical results enable vivid flow visualizations inside the channel, providing a great understanding of the development of the flow. The two stages EHD gas pump, which can be produced and sustained air flows with a maximum volume flow rate is considered more efficient when it is operated with uneven applied voltages. The results show that EHD technique has a great potential for many engineering applications.
American Society of Mechanical Engineers
Title: Performance Enhancement of Two Stages EHD Gas Pump in a Rectangular Channel With Uneven Voltages
Description:
Abstract
In this study, performance enhancement of a two stage electrohydrodynamic (EHD) gas pump in a rectangular channel has been evaluated by experimental measurement and numerical simulations.
This study is implemented by a two stage EHD gas pump with uneven voltages for 8 emitting electrodes configuration to seek the relation between the number of stages and applied voltages.
The EHD pump is evaluated for a combination of three different operating voltages (20 kV, 24 kV, and 28 kV) for further enhancement in its performance.
To achieve the maximum enhancement, the emitting electrodes of the EHD gas pump are flush mounted on the channel walls so that the corona wind produced directly disturbs the boundary layer thickness and improves gas pumping.
Velocities are measured at three cross-sections along the tube length and then integrated to obtain the volume flow rate.
The numerical results enable vivid flow visualizations inside the channel, providing a great understanding of the development of the flow.
The two stages EHD gas pump, which can be produced and sustained air flows with a maximum volume flow rate is considered more efficient when it is operated with uneven applied voltages.
The results show that EHD technique has a great potential for many engineering applications.
Related Results
Abstract 19130: Is Early Hospital Discharge Safe After Adult Heart Transplantation?
Abstract 19130: Is Early Hospital Discharge Safe After Adult Heart Transplantation?
Introduction:
The impact of early hospital discharge (EHD) after adult heart transplantation (HT) on longitudinal outcomes is unclear. Many HT recipients are intentiona...
[RETRACTED] Gro-X Male Enhancement | Safely Grow Your Size, Sex Drive v1
[RETRACTED] Gro-X Male Enhancement | Safely Grow Your Size, Sex Drive v1
[RETRACTED]Gro-X Male Enhancement Reviews - Is It Worth the Money? Scam or Legit? Gro-X Male Enhancement Male health is very important, especially for a couple. Low sperm count an...
En skvatmølle i Ljørring
En skvatmølle i Ljørring
A Horizontal Mill at Ljørring, Jutland.Horizontal water-mills have been in use in Jutland since the beginning of the Christian era 2). But the one here described shows so close a c...
[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED] Rhino XL Male Enhancement v1
[RETRACTED]Rhino XL Reviews, NY USA: Studies show that testosterone levels in males decrease constantly with growing age. There are also many other problems that males face due ...
Heat transport in turbulent electro-hydrodynamics
Heat transport in turbulent electro-hydrodynamics
<p>Electro-hydrodynamics (EHD) plays an important role in many industrial applications. Ink-jet printers, microwave drying facilities, and lab-on-a-chip devices utili...
Enzymatically hydrolyzed diet improves growth performance and intestinal microbiome in growing pigs
Enzymatically hydrolyzed diet improves growth performance and intestinal microbiome in growing pigs
BackgroundThe use of enzymes within pig feed can reduce the challenges associated with antibiotic-free animal feeding. However, this enzymatic effect is often limited by the intern...
Velocity Measurement of EHD Flow Produced by Pin-Multi Concentric Ring Electrodes Generator
Velocity Measurement of EHD Flow Produced by Pin-Multi Concentric Ring Electrodes Generator
Study of EHD flow by using generator corona discharge with electrodes configuration of pin to multi concentric rings (MCR) and pin to single ring (SR) have been curried out. We mea...
Pumping Unit Optimization
Pumping Unit Optimization
Abstract
In order to produce available fluids, pump jacks used at surface have been engineered to stroke as slow as 6 (six) strokes per minute (SPM) and as fast a...

