Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

A New Windings Design of 24 Slot Capacitor-Start Capacitor-Run Induction Motor

View through CrossRef
The conventional method of a single phase induction motor windings design usually constructed the main and auxiliary windings in both slot. So, there was a complicated winding design if that compare to the three-phase induction motor. Because of that, this study was aimed to design a new windings design of a single phase induction motor that construction like a three-phase induction motor. This study was focused to design a 24 slot capacitor-start capacitor-run induction motor. The windings in the motor are divided in 3 group like a three-phase induction motor. The two windings act as a main windings and the other winding act as auxiliary winding. The current rating of the winding of the proposed single-phase induction motor was 2.74A. The performances of the proposed method were compared with the performances of a three-phase induction motor that had the same current rating. The motor used as a comparator was a three-phase induction of 380/220V, 2.74/4.7A, Y/Δ, cage rotor, 4 poles, 1.5 HP, 1400 RPM, 50Hz. The result of this study showed that the proposed design of single phase induction motor could be operated with better performances than the three-phase comparator induction motor’s.
Title: A New Windings Design of 24 Slot Capacitor-Start Capacitor-Run Induction Motor
Description:
The conventional method of a single phase induction motor windings design usually constructed the main and auxiliary windings in both slot.
So, there was a complicated winding design if that compare to the three-phase induction motor.
Because of that, this study was aimed to design a new windings design of a single phase induction motor that construction like a three-phase induction motor.
This study was focused to design a 24 slot capacitor-start capacitor-run induction motor.
The windings in the motor are divided in 3 group like a three-phase induction motor.
The two windings act as a main windings and the other winding act as auxiliary winding.
The current rating of the winding of the proposed single-phase induction motor was 2.
74A.
The performances of the proposed method were compared with the performances of a three-phase induction motor that had the same current rating.
The motor used as a comparator was a three-phase induction of 380/220V, 2.
74/4.
7A, Y/Δ, cage rotor, 4 poles, 1.
5 HP, 1400 RPM, 50Hz.
The result of this study showed that the proposed design of single phase induction motor could be operated with better performances than the three-phase comparator induction motor’s.

Related Results

Kinerja Motor Induksi 1-fasa Disain 4 Kumparan dengan Kapasitansi Kapasitor Jalan Terkendali
Kinerja Motor Induksi 1-fasa Disain 4 Kumparan dengan Kapasitansi Kapasitor Jalan Terkendali
Single phase induction motor usually has two windings. Because of that, the motor usually operated at lower efficiency than the poly-phase induction motor. A new design had been de...
Sliding Mode Controlled drives for wide speed operation of Threephase Induction Motor
Sliding Mode Controlled drives for wide speed operation of Threephase Induction Motor
Induction motor is widely used due to advantages in terms of performance, size, maintenance and efficiency compared to dc motor. Induction motor is either Scalar Controlled or Vect...
Analisis Pengaruh Desain Kumparan 6-Fasa Terhadap Torsi Dan Kecepatan Motor Induksi 3-Fasa Berbasis Desain 3 Fasa Ganda Tak Simetris
Analisis Pengaruh Desain Kumparan 6-Fasa Terhadap Torsi Dan Kecepatan Motor Induksi 3-Fasa Berbasis Desain 3 Fasa Ganda Tak Simetris
This study aims to examine the impact of a 6-phase design using an asymmetrical dual 3-phase design on the torque and speed of an induction motor, where the newly designed motor ...
Perbandingan Kinerja Perusahaan Dengan Metode Balanced Scorecard
Perbandingan Kinerja Perusahaan Dengan Metode Balanced Scorecard
The purpose of this study is to compare the performance of two Honda service companies with the Balanced Scorecard method. The research locations are Aneka Motor Denpasar and Niki ...
PENGASUTAN MOTOR INDUKSI TIGA PHASA PADA PENGEMBANGAN INSTALASI TENAGA DAN INSTALASI PENERANGAN DI BENGKEL LISTRIK
PENGASUTAN MOTOR INDUKSI TIGA PHASA PADA PENGEMBANGAN INSTALASI TENAGA DAN INSTALASI PENERANGAN DI BENGKEL LISTRIK
Abstract The use of an induction motor in an electrical power generation system is needed where the usefulness of an induction motor is as driving. Constraints on the ...
Experimental Study on the Effects of Slot Jet on Film Cooling Performance in the Cascade Endwall With Purge Flow
Experimental Study on the Effects of Slot Jet on Film Cooling Performance in the Cascade Endwall With Purge Flow
Abstract Based on the infrared temperature measurement technology, in this paper, the effect of the purge flow from the upstream slot on the film cooling performance...