Full-scale annular experimental evaluation of two different high pressure turbine first stage vane cooling designs was carried out using high frequency surface heat-flux measurements in the Turbine Research Facility at the Air Force Research Laboratory. A baseline film cooling geometry was tested simultaneously with a genetically optimized vane aimed to improve efficiency and part life. Part 1 of this two-part paper describes the experimental instrumentation, test facility, and surface heat flux measurements used to evaluate both cooling schemes. Part 2 of this paper describes the result of companion conjugate heat transfer posttest predictions, and gives numerical background on the design and modelling of both film cooling geometries.
Time-resolved surface heat flux data is captured at multiple airfoil span and chord locations for each cooling design. Area based assessment of surface flux data verifies the genetic optimization redistributes excessive cooling away from midspan areas to improve efficiency. Results further reveal key discrepancies between design intent and real hardware behavior. Elevated heat flux above intent in some areas led to investigation of backflow margin and unsteady hot gas ingestion at certain film holes. Analysis shows areas toward the vane inner and outer endwalls of the aft pressure side were more sensitive to reduced aft cavity backflow margin. In addition, temporal analysis shows film cooled heat flux having large high frequency fluctuations that can vary across nearly the full range of film cooling effectiveness at some locations. Velocity and acceleration of these large unsteady heat flux events moving near the endwall of the vane pressure side is reported for the first time. The temporal nature of the unsteady 3-D film cooling features are a large factor in determining average local heat flux levels. This study determined this effect to be particularly important in areas on real hardware along the HPT vane pressure side endwalls towards the trailing edge, where numerical assumptions are often challenged. Better understanding of the physics of the highly unsteady 3D film cooled flow features occurring in real hardware is necessary to accurately predict distress progression in localized areas, prevent unforeseen part failures, and enable improvements to turbine engine efficiency. The results of this two-part paper are relevant to engines in extended service today.
American Society of Mechanical Engineers
Title: 3D Heat Transfer Assessment of Full-Scale Inlet Vanes With Surface-Optimized Film Cooling: Part 1 — Experimental Results
Description:
Abstract
Full-scale annular experimental evaluation of two different high pressure turbine first stage vane cooling designs was carried out using high frequency surface heat-flux measurements in the Turbine Research Facility at the Air Force Research Laboratory.
A baseline film cooling geometry was tested simultaneously with a genetically optimized vane aimed to improve efficiency and part life.
Part 1 of this two-part paper describes the experimental instrumentation, test facility, and surface heat flux measurements used to evaluate both cooling schemes.
Part 2 of this paper describes the result of companion conjugate heat transfer posttest predictions, and gives numerical background on the design and modelling of both film cooling geometries.
Time-resolved surface heat flux data is captured at multiple airfoil span and chord locations for each cooling design.
Area based assessment of surface flux data verifies the genetic optimization redistributes excessive cooling away from midspan areas to improve efficiency.
Results further reveal key discrepancies between design intent and real hardware behavior.
Elevated heat flux above intent in some areas led to investigation of backflow margin and unsteady hot gas ingestion at certain film holes.
Analysis shows areas toward the vane inner and outer endwalls of the aft pressure side were more sensitive to reduced aft cavity backflow margin.
In addition, temporal analysis shows film cooled heat flux having large high frequency fluctuations that can vary across nearly the full range of film cooling effectiveness at some locations.
Velocity and acceleration of these large unsteady heat flux events moving near the endwall of the vane pressure side is reported for the first time.
The temporal nature of the unsteady 3-D film cooling features are a large factor in determining average local heat flux levels.
This study determined this effect to be particularly important in areas on real hardware along the HPT vane pressure side endwalls towards the trailing edge, where numerical assumptions are often challenged.
Better understanding of the physics of the highly unsteady 3D film cooled flow features occurring in real hardware is necessary to accurately predict distress progression in localized areas, prevent unforeseen part failures, and enable improvements to turbine engine efficiency.
The results of this two-part paper are relevant to engines in extended service today.
Related Results
CFD investigation of flow through a centrifugal compressor diffuser with splitter blades
CFD investigation of flow through a centrifugal compressor diffuser with splitter blades
AbstractThe aerodynamic losses in centrifugal compressors are mainly associated with the separated flow on the suction sides of impeller and diffuser vanes. The overall performance...
Effects of Inlet Swirl on Endwall Film Cooling in Neighboring Vane Passages
Effects of Inlet Swirl on Endwall Film Cooling in Neighboring Vane Passages
The distribution of film cooling effectiveness of endwall film-cooling holes is considered to be periodic between neighboring high pressure turbine passages in most cascade experim...
Application of Machine Learning Based Meta Models for Predicting Film Cooling Effectiveness in Gas Turbine Blades
Application of Machine Learning Based Meta Models for Predicting Film Cooling Effectiveness in Gas Turbine Blades
Abstract
In Large Gas Turbines, turbine components in particular blades and vanes operate at significantly high temperatures. As a result, cooling of these component...
Film Cooling Calculations With an Iterative Conjugate Heat Transfer Approach Using Empirical Heat Transfer Coefficient Corrections
Film Cooling Calculations With an Iterative Conjugate Heat Transfer Approach Using Empirical Heat Transfer Coefficient Corrections
An iterative conjugate heat transfer technique has been developed to predict the temperatures on film cooled surfaces such as flat plates and turbine blades. Conventional approache...
Predicting streetscape green infrastructure performance amidst uncertain inflow
Predicting streetscape green infrastructure performance amidst uncertain inflow
Sustainable cities feature infrastructure that is adaptive to a wide range of spatially and temporally variable conditions. Water infrastructure needs to be responsive to both the ...
Reclaiming the Wasteland: Samson and Delilah and the Historical Perception and Construction of Indigenous Knowledges in Australian Cinema
Reclaiming the Wasteland: Samson and Delilah and the Historical Perception and Construction of Indigenous Knowledges in Australian Cinema
It was always based on a teenage love story between the two kids. One is a sniffer and one is not. It was designed for Central Australia because we do write these kids off there. N...
ANALISIS PERTIMBANGAN MAHKAMAH AGUNG DALAM MENGABULKAN KASASI TERDAKWA (STUDI PUTUSAN NOMOR 2959/K/PID.SUS/2022)
ANALISIS PERTIMBANGAN MAHKAMAH AGUNG DALAM MENGABULKAN KASASI TERDAKWA (STUDI PUTUSAN NOMOR 2959/K/PID.SUS/2022)
<p><em><span class="markedContent"><span style="left: calc(var(--scale-factor)*195.53px); top: calc(var(--scale-factor)*496.87px); font-size: calc(var(--scale-...
Effect of non-isothermality on film cooling effectiveness under partial blockage of coolant injection holes
Effect of non-isothermality on film cooling effectiveness under partial blockage of coolant injection holes
Modern gas turbine units (GTUs) operate at extremely high temperatures, with mainstream gas temperatures reaching 1700–1750 °C in transport and military applications, while heat-re...